True detection versus "accidental" detection of small lung cancer by a computer-aided detection (CAD) program on chest radiographs.

Feng Li1, Roger Engelmann, Kunio Doi, Heber Macmahon.   

Abstract

To evaluate the number of actual detections versus "accidental" detections by a computer-aided detection (CAD) system for small nodular lung cancers (<or=30 mm) on chest radiographs, using two different criteria for measuring performance. A Food-and-Drug-Administration-approved CAD program (version 1.0; Riverain Medical) was applied to 34 chest radiographs with a "radiologist-missed" nodular cancer and 36 radiographs with a radiologist-mentioned nodule (a newer version 3.0 was also applied to the 36-case database). The marks applied by this CAD system consisted of 5-cm-diameter circles. A strict "nodule-in-center" criterion and a generous "nodule-in-circle" criterion were compared as methods for the calculation of CAD sensitivity. The increased sensitivities by the nodule-in-circle criterion were considered as nodules detected by chance. The number of false-positive (FP) marks was also analyzed. For the 34 radiologist-missed cancers, the nodule-in-circle criterion caused eight more cancers (24%) to be detected by chance, as compared to the nodule-in-center criterion, when using the version 1.0 results. For the 36 radiologist-mentioned nodules, the nodule-in-circle criterion caused seven more lesions (19%) to be detected by chance, as compared to the nodule-in-center criterion, when using the version 1.0 results, and three more lesions (8%) to be detected by chance when using the version 3.0 results. Version 1.0 yielded a mean of six FP marks per image, while version 3.0 yielded only three FP marks per image. The specific criteria used to define true- and false-positive CAD detections can substantially influence the apparent accuracy of a CAD system.

Entities:  

Mesh:

Year:  2009        PMID: 19421813      PMCID: PMC3043747          DOI: 10.1007/s10278-009-9201-0

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  12 in total

1.  Computer-aided diagnosis for improved detection of lung nodules by use of posterior-anterior and lateral chest radiographs.

Authors:  Junji Shiraishi; Feng Li; Kunio Doi
Journal:  Acad Radiol       Date:  2007-01       Impact factor: 3.173

2.  Multiprojection correlation imaging for improved detection of pulmonary nodules.

Authors:  Ehsan Samei; Stanton A Stebbins; James T Dobbins; H Page McAdams; Joseph Y Lo
Journal:  AJR Am J Roentgenol       Date:  2007-05       Impact factor: 3.959

3.  Computerized detection of clustered microcalcifications: evaluation of performance on mammograms from multiple centers.

Authors:  R M Nishikawa; K Doi; M L Giger; R A Schmidt; C J Vyborny; L Monnier-Cholley; J Papaioannou; P Lu
Journal:  Radiographics       Date:  1995-03       Impact factor: 5.333

4.  Effect of case selection on the performance of computer-aided detection schemes.

Authors:  R M Nishikawa; M L Giger; K Doi; C E Metz; F F Yin; C J Vyborny; R A Schmidt
Journal:  Med Phys       Date:  1994-02       Impact factor: 4.071

5.  Computer-aided detection in the United Kingdom National Breast Screening Programme: prospective study.

Authors:  Lisanne A L Khoo; Paul Taylor; Rosalind M Given-Wilson
Journal:  Radiology       Date:  2005-11       Impact factor: 11.105

6.  Improved detection of lung nodules on chest radiographs using a commercial computer-aided diagnosis system.

Authors:  Shingo Kakeda; Junji Moriya; Hiromi Sato; Takatoshi Aoki; Hideyuki Watanabe; Hajime Nakata; Nobuhiro Oda; Shigehiko Katsuragawa; Keiji Yamamoto; Kunio Doi
Journal:  AJR Am J Roentgenol       Date:  2004-02       Impact factor: 3.959

7.  Lung cancers missed on chest radiographs: results obtained with a commercial computer-aided detection program.

Authors:  Feng Li; Roger Engelmann; Charles E Metz; Kunio Doi; Heber MacMahon
Journal:  Radiology       Date:  2008-01       Impact factor: 11.105

8.  Computer-aided detection output on 172 subtle findings on normal mammograms previously obtained in women with breast cancer detected at follow-up screening mammography.

Authors:  Debra M Ikeda; Robyn L Birdwell; Kathryn F O'Shaughnessy; Edward A Sickles; R James Brenner
Journal:  Radiology       Date:  2004-02-05       Impact factor: 11.105

9.  Evaluation of computer-aided detection systems in the detection of small invasive breast carcinoma.

Authors:  Richard L Ellis; Andrew A Meade; Michelle A Mathiason; Kathy M Willison; Wende Logan-Young
Journal:  Radiology       Date:  2007-10       Impact factor: 11.105

10.  Sensitivity of noncommercial computer-aided detection system for mammographic breast cancer detection: pilot clinical trial.

Authors:  Mark A Helvie; Lubomir Hadjiiski; Erini Makariou; Heang-Ping Chan; Nicholas Petrick; Berkman Sahiner; Shih-Chung B Lo; Matthew Freedman; Dorit Adler; Janet Bailey; Caroline Blane; Donna Hoff; Karen Hunt; Lynn Joynt; Katherine Klein; Chintana Paramagul; Stephanie K Patterson; Marilyn A Roubidoux
Journal:  Radiology       Date:  2004-02-27       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.