Literature DB >> 17446523

High-spatial-resolution contrast-enhanced MR angiography of the intracranial venous system with fourfold accelerated two-dimensional sensitivity encoding.

Houchun H Hu1, Norbert G Campeau, John Huston, David G Kruger, Clifton R Haider, Stephen J Riederer.   

Abstract

Informed consent was obtained; the study was HIPAA compliant and institutional review board approved. Fourfold accelerated (FFA) two-dimensional (2D) sensitivity encoding (SENSE) (65 seconds) was prospectively compared with its nonaccelerated counterpart (4 minutes 20 seconds) for diagnostic image quality and sharpness of visualization of blood vessels at 1.5 T with three-dimensional (3D) intracranial contrast-enhanced magnetic resonance venography in 18 consecutive volunteers (10 men, eight women; mean age, 48.4 years) and two patients (55-year-old man, 30-year-old woman). Two readers compared FFA 2D SENSE results with results from its nonaccelerated counterpart; they rated visualization of large and medium sinuses as equivalent (P>.1) and that of small deep cerebral veins (P<.01) and superficial cerebral veins (P<.001) as superior. Overall diagnostic image quality ratings were excellent for 62% and 80% of nonaccelerated and FFA 2D SENSE results, respectively (P<.05). FFA 2D SENSE may become the method of choice for fast visualization of intracranial venous vasculature in clinical practice. (c) RSNA, 2007.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17446523      PMCID: PMC2813572          DOI: 10.1148/radiol.2433060819

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  28 in total

1.  Theoretical limits of spatial resolution in elliptical-centric contrast-enhanced 3D-MRA.

Authors:  S B Fain; S J Riederer; M A Bernstein; J Huston
Journal:  Magn Reson Med       Date:  1999-12       Impact factor: 4.668

2.  MR angiography of the intracranial venous system.

Authors:  L Liauw; M A van Buchem; A Spilt; F T de Bruïne; R van den Berg; J Hermans; M N Wasser
Journal:  Radiology       Date:  2000-03       Impact factor: 11.105

3.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

4.  Contrast-enhanced 3D MRA using SENSE.

Authors:  M Weiger; K P Pruessmann; A Kassner; G Roditi; T Lawton; A Reid; P Boesiger
Journal:  J Magn Reson Imaging       Date:  2000-11       Impact factor: 4.813

5.  Fast contrast-enhanced MR whole-brain venography.

Authors:  Karl-Olof Lövblad; Jacques Schneider; Claudio Bassetti; Marwan El-Koussy; Raphael Guzman; Oliver Heid; Luca Remonda; Gerhard Schroth
Journal:  Neuroradiology       Date:  2002-07-06       Impact factor: 2.804

6.  Comparison of different MR venography techniques for detecting transverse sinus stenosis in idiopathic intracranial hypertension.

Authors:  Francesco Fera; Francesco Bono; Demetrio Messina; Olivier Gallo; Pier Luigi Lanza; William Auteri; Giuseppe Nicoletti; Giuseppe Santoro; Aldo Quattrone
Journal:  J Neurol       Date:  2005-03-07       Impact factor: 4.849

7.  Evaluation of the intracranial dural sinuses with a 3D contrast-enhanced MP-RAGE sequence: prospective comparison with 2D-TOF MR venography and digital subtraction angiography.

Authors:  L Liang; Y Korogi; T Sugahara; M Onomichi; Y Shigematsu; D Yang; M Kitajima; Y Hiai; M Takahashi
Journal:  AJNR Am J Neuroradiol       Date:  2001-03       Impact factor: 3.825

8.  Role of contrast-enhanced MR venography in the preoperative evaluation of parasagittal meningiomas.

Authors:  Alessandro Bozzao; Vanina Finocchi; Andrea Romano; Michele Ferrante; Fabrizio Fasoli; Giuseppe Trillò; Luigi Ferrante; Luigi Maria Fantozzi
Journal:  Eur Radiol       Date:  2005-05-20       Impact factor: 5.315

9.  Cerebral MR venography: normal anatomy and potential diagnostic pitfalls.

Authors:  R H Ayanzen; C R Bird; P J Keller; F J McCully; M R Theobald; J E Heiserman
Journal:  AJNR Am J Neuroradiol       Date:  2000-01       Impact factor: 3.825

10.  2D SENSE for faster 3D MRI.

Authors:  Markus Weiger; Klaas P Pruessmann; Peter Boesiger
Journal:  MAGMA       Date:  2002-03       Impact factor: 2.533

View more
  9 in total

1.  Intracranial contrast-enhanced magnetic resonance venography with 6.4-fold sensitivity encoding at 1.5 and 3.0 Tesla.

Authors:  Houchun H Hu; Clifton R Haider; Norbert G Campeau; John Huston; Stephen J Riederer
Journal:  J Magn Reson Imaging       Date:  2008-03       Impact factor: 4.813

2.  3T high-spatial-resolution contrast-enhanced MR angiography of the intracranial venous system with parallel imaging.

Authors:  M Lettau; K Sartor; S Heiland; S Hähnel
Journal:  AJNR Am J Neuroradiol       Date:  2008-07-17       Impact factor: 3.825

3.  Time-of-arrival mapping at three-dimensional time-resolved contrast-enhanced MR angiography.

Authors:  Stephen J Riederer; Clifton R Haider; Eric A Borisch
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

4.  Cerebral venous thrombosis: diagnostic accuracy of combined, dynamic and static, contrast-enhanced 4D MR venography.

Authors:  S Meckel; C Reisinger; J Bremerich; D Damm; M Wolbers; S Engelter; K Scheffler; S G Wetzel
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-05       Impact factor: 3.825

5.  Recent advances in 3D time-resolved contrast-enhanced MR angiography.

Authors:  Stephen J Riederer; Clifton R Haider; Eric A Borisch; Paul T Weavers; Phillip M Young
Journal:  J Magn Reson Imaging       Date:  2015-06-01       Impact factor: 4.813

6.  Three-station three-dimensional bolus-chase MR angiography with real-time fluoroscopic tracking.

Authors:  Casey P Johnson; Paul T Weavers; Eric A Borisch; Roger C Grimm; Thomas C Hulshizer; Christine C LaPlante; Phillip J Rossman; James F Glockner; Phillip M Young; Stephen J Riederer
Journal:  Radiology       Date:  2014-03-14       Impact factor: 11.105

7.  Max CAPR: high-resolution 3D contrast-enhanced MR angiography with acquisition times under 5 seconds.

Authors:  Clifton R Haider; Eric A Borisch; James F Glockner; Petrice M Mostardi; Phillip J Rossman; Phillip M Young; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2010-10       Impact factor: 4.668

8.  Inversion recovery with embedded self-calibration (IRES).

Authors:  Ek T Tan; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2009-08       Impact factor: 4.668

9.  Early Detection and Quantification of Cerebral Venous Thrombosis by Magnetic Resonance Black-Blood Thrombus Imaging.

Authors:  Qi Yang; Jiangang Duan; Zhaoyang Fan; Xiaofeng Qu; Yibin Xie; Christopher Nguyen; Xiangying Du; Xiaoming Bi; Kuncheng Li; Xunming Ji; Debiao Li
Journal:  Stroke       Date:  2015-12-15       Impact factor: 7.914

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.