Literature DB >> 17442524

Zero and first-order phase shift correction for field map estimation with dual-echo GRE using bipolar gradients.

Desmond T B Yeo1, Thomas L Chenevert, Jeffrey A Fessler, Boklye Kim.   

Abstract

A simple phase error correction technique used for field map estimation with a generally available dual-echo gradient-echo (GRE) sequence is presented. Magnetic field inhomogeneity maps estimated using two separate GRE volume acquisitions at different echo times are prone to dynamic motion errors between acquisitions. By using the dual-echo sequence, the data are collected during two back-to-back readout gradients in opposite polarity after a single radio frequency pulse, and interecho motion artifacts and alignment errors in field map estimation can be factored out. Residual phase error from the asymmetric readout pulses is modeled as an affine term in the readout direction. Results from phantom and human data suggest that the first-order phase correction term stays constant over time and, hence, can be applied to different data acquired with the same protocol over time. The zero-order phase correction term may change with time and is estimated empirically for different scans.

Entities:  

Mesh:

Year:  2007        PMID: 17442524      PMCID: PMC2795570          DOI: 10.1016/j.mri.2007.02.001

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  12 in total

1.  An inverse problem approach to the correction of distortion in EPI images.

Authors:  P Munger; G R Crelier; T M Peters; G B Pike
Journal:  IEEE Trans Med Imaging       Date:  2000-07       Impact factor: 10.048

2.  Motion correction in fMRI via registration of individual slices into an anatomical volume.

Authors:  B Kim; J L Boes; P H Bland; T L Chenevert; C R Meyer
Journal:  Magn Reson Med       Date:  1999-05       Impact factor: 4.668

3.  Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities.

Authors:  Bradley P Sutton; Douglas C Noll; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2003-02       Impact factor: 10.048

4.  Single-shot magnetic field mapping embedded in echo-planar time-course imaging.

Authors:  Vinai Roopchansingh; Robert W Cox; Andrzej Jesmanowicz; B Douglas Ward; James S Hyde
Journal:  Magn Reson Med       Date:  2003-10       Impact factor: 4.668

5.  New robust 3-D phase unwrapping algorithms: application to magnetic field mapping and undistorting echoplanar images.

Authors:  R Cusack; N Papadakis
Journal:  Neuroimage       Date:  2002-07       Impact factor: 6.556

6.  An evaluation of the use of magnetic field maps to undistort echo-planar images.

Authors:  Rhodri Cusack; Matthew Brett; Katja Osswald
Journal:  Neuroimage       Date:  2003-01       Impact factor: 6.556

7.  Rapid, fully automatic, arbitrary-volume in vivo shimming.

Authors:  P Webb; A Macovski
Journal:  Magn Reson Med       Date:  1991-07       Impact factor: 4.668

8.  Correction for geometric distortion in echo planar images from B0 field variations.

Authors:  P Jezzard; R S Balaban
Journal:  Magn Reson Med       Date:  1995-07       Impact factor: 4.668

9.  Correction of off resonance-related distortion in echo-planar imaging using EPI-based field maps.

Authors:  P J Reber; E C Wong; R B Buxton; L R Frank
Journal:  Magn Reson Med       Date:  1998-02       Impact factor: 4.668

10.  Quantification of low-velocity motion using a navigator-echo supported MR velocity-mapping technique: application to intracranial dynamics in volunteers and patients with brain tumours.

Authors:  R Wirestam; L G Salford; C Thomsen; S Brockstedt; B R Persson; F Ståhlberg
Journal:  Magn Reson Imaging       Date:  1997       Impact factor: 2.546

View more
  4 in total

1.  Multi-parametric neuroimaging reproducibility: a 3-T resource study.

Authors:  Bennett A Landman; Alan J Huang; Aliya Gifford; Deepti S Vikram; Issel Anne L Lim; Jonathan A D Farrell; John A Bogovic; Jun Hua; Min Chen; Samson Jarso; Seth A Smith; Suresh Joel; Susumu Mori; James J Pekar; Peter B Barker; Jerry L Prince; Peter C M van Zijl
Journal:  Neuroimage       Date:  2010-11-20       Impact factor: 6.556

2.  Phase-corrected bipolar gradients in multi-echo gradient-echo sequences for quantitative susceptibility mapping.

Authors:  Jianqi Li; Shixin Chang; Tian Liu; Hongwei Jiang; Fang Dong; Mengchao Pei; Qianfeng Wang; Yi Wang
Journal:  MAGMA       Date:  2014-11-20       Impact factor: 2.310

3.  An Actively Decoupled Dual Transceiver Coil System for Continuous ASL at 7 T.

Authors:  Randall B Stafford; Myung-Kyun Woo; Se-Hong Oh; Sudipto Dolui; Tiejun Zhao; Young-Bo Kim; John A Detre; Zang-Hee Cho; Jongho Lee
Journal:  Int J Imaging Syst Technol       Date:  2016-06-16       Impact factor: 2.000

4.  Quantitative assessment of the susceptibility artefact and its interaction with motion in diffusion MRI.

Authors:  Mark S Graham; Ivana Drobnjak; Mark Jenkinson; Hui Zhang
Journal:  PLoS One       Date:  2017-10-02       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.