Literature DB >> 1943653

Rapid, fully automatic, arbitrary-volume in vivo shimming.

P Webb1, A Macovski.   

Abstract

MR spectroscopy and many MR imaging methods benefit from a well-shimmed magnet. We have developed a pulse sequence which enables fast and accurate measurement of three-dimensional field maps in vivo, and a data analysis package that allows calculation of shim currents to optimally shim arbitrary selected volumes. A data link to the shim power supply allows automatic update of currents. No intervention by the operator is required. Typical in vivo shimming time is less than 5 min. Performance analysis, phantom, and in vivo results are presented.

Mesh:

Year:  1991        PMID: 1943653     DOI: 10.1002/mrm.1910200112

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  24 in total

1.  Noncontrast SSFP pulmonary vein magnetic resonance angiography: impact of off-resonance and flow.

Authors:  Peng Hu; Christian T Stoeck; Jouke Smink; Dana C Peters; Long Ngo; Beth Goddu; Kraig V Kissinger; Lois A Goepfert; Jonathan Chan; Thomas H Hauser; Neil M Rofsky; Warren J Manning; Reza Nezafat
Journal:  J Magn Reson Imaging       Date:  2010-11       Impact factor: 4.813

2.  Natural linewidth chemical shift imaging (NL-CSI).

Authors:  Adil Bashir; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2006-07       Impact factor: 4.668

3.  Investigation of feline brain anatomy for the detection of cortical spreading depression with magnetic resonance imaging.

Authors:  J M Smith; M F James; K H Bockhorst; M I Smith; D P Bradley; N G Papadakis; T A Carpenter; A A Parsons; R A Leslie; L D Hall; C L Huang
Journal:  J Anat       Date:  2001-05       Impact factor: 2.610

4.  Multi-parametric neuroimaging reproducibility: a 3-T resource study.

Authors:  Bennett A Landman; Alan J Huang; Aliya Gifford; Deepti S Vikram; Issel Anne L Lim; Jonathan A D Farrell; John A Bogovic; Jun Hua; Min Chen; Samson Jarso; Seth A Smith; Suresh Joel; Susumu Mori; James J Pekar; Peter B Barker; Jerry L Prince; Peter C M van Zijl
Journal:  Neuroimage       Date:  2010-11-20       Impact factor: 6.556

5.  Zero and first-order phase shift correction for field map estimation with dual-echo GRE using bipolar gradients.

Authors:  Desmond T B Yeo; Thomas L Chenevert; Jeffrey A Fessler; Boklye Kim
Journal:  Magn Reson Imaging       Date:  2007-04-18       Impact factor: 2.546

6.  Improved shim method based on the minimization of the maximum off-resonance frequency for balanced steady-state free precession (bSSFP).

Authors:  Jongho Lee; Michael Lustig; Dong-hyun Kim; John M Pauly
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

7.  Automatic high-order shimming using parallel columns mapping (PACMAP).

Authors:  Yan Zhang; Shizhe Li; Jun Shen
Journal:  Magn Reson Med       Date:  2009-10       Impact factor: 4.668

8.  Fast concomitant gradient field and field inhomogeneity correction for spiral cardiac imaging.

Authors:  Joseph Y Cheng; Juan M Santos; John M Pauly
Journal:  Magn Reson Med       Date:  2011-03-07       Impact factor: 4.668

9.  Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experiments.

Authors:  Mina Kim; Joseph Gillen; Bennett A Landman; Jinyuan Zhou; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

10.  Improved shimming for fMRI specifically optimizing the local BOLD sensitivity.

Authors:  Evelyne Balteau; Chloe Hutton; Nikolaus Weiskopf
Journal:  Neuroimage       Date:  2009-08-12       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.