Literature DB >> 1743835

Radiological study of alignment after total knee replacement. Short radiographs or long radiographs?

D V Patel1, B D Ferris, P M Aichroth.   

Abstract

The axial alignment on short and long radiographs was measured in 50 knees in 34 patients who had undergone posteriorly stabilised (Insall-Burstein) condylar knee arthroplasty. A mean difference of 1.6 degrees was found when the tibiofemoral angles were compared on short and long radiographs. Short radiographs are probably adequate for routine assessment of knee replacements in a busy out-patient clinic, but for accurate scientific studies the long radiographs are preferable.

Entities:  

Mesh:

Year:  1991        PMID: 1743835     DOI: 10.1007/bf00192296

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  10 in total

1.  The total condylar prosthesis. 10- to 12-year results of a cemented knee replacement.

Authors:  K G Vince; J N Insall; M A Kelly
Journal:  J Bone Joint Surg Br       Date:  1989-11

2.  Posteriorly stabilised total-condylar knee replacement. Three to eight years' follow-up of 85 knees.

Authors:  P Aglietti; R Buzzi
Journal:  J Bone Joint Surg Br       Date:  1988-03

3.  Radiographic assessment of knee alignment after total knee arthroplasty.

Authors:  T L Petersen; G A Engh
Journal:  J Arthroplasty       Date:  1988       Impact factor: 4.757

4.  A method for quantitative analysis of medial and lateral compression forces at the knee during standing.

Authors:  D B Kettelkamp; E Y Chao
Journal:  Clin Orthop Relat Res       Date:  1972 Mar-Apr       Impact factor: 4.176

5.  A clinical and radiographic analysis of loosening of total knee arthroplasty components using a bilateral model.

Authors:  C N Cornell; C S Ranawat; A H Burstein
Journal:  J Arthroplasty       Date:  1986       Impact factor: 4.757

6.  Radiographic analysis of the axial alignment of the lower extremity.

Authors:  J R Moreland; L W Bassett; G J Hanker
Journal:  J Bone Joint Surg Am       Date:  1987-06       Impact factor: 5.284

7.  Influence of positioning of prosthesis in total knee replacement.

Authors:  P A Lotke; M L Ecker
Journal:  J Bone Joint Surg Am       Date:  1977-01       Impact factor: 5.284

8.  Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations.

Authors:  J H Bargren; J D Blaha; M A Freeman
Journal:  Clin Orthop Relat Res       Date:  1983-03       Impact factor: 4.176

9.  Tibiofemoral alignment and the results of knee replacement.

Authors:  M Tew; W Waugh
Journal:  J Bone Joint Surg Br       Date:  1985-08

10.  The distribution of load across the knee. A comparison of static and dynamic measurements.

Authors:  F Johnson; S Leitl; W Waugh
Journal:  J Bone Joint Surg Br       Date:  1980-08
  10 in total
  11 in total

1.  [Precise, computed-assisted leg angle correction with open-wedge high tibial osteotomy].

Authors:  R Hart; V Stipcák; B Kucera; P Filan; J deCordeiro
Journal:  Orthopade       Date:  2007-06       Impact factor: 1.087

2.  Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine?

Authors:  Markus Tingart; Christian Lüring; Holger Bäthis; Johannes Beckmann; Joachim Grifka; Lars Perlick
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-09-26       Impact factor: 4.342

3.  Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty.

Authors:  Ralf E Rosenberger; Christian Hoser; Sebastian Quirbach; Rene Attal; Alfred Hennerbichler; Christian Fink
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-12-22       Impact factor: 4.342

4.  Minimal invasive and computer assisted total knee replacement compared with the conventional technique: a prospective, randomised trial.

Authors:  C Lüring; J Beckmann; P Haiböck; L Perlick; J Grifka; M Tingart
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-07-17       Impact factor: 4.342

5.  Total knee arthroplasty implanted with and without kinematic navigation.

Authors:  R Hart; M Janecek; A Chaker; P Bucek
Journal:  Int Orthop       Date:  2003-08-26       Impact factor: 3.075

6.  Reliability of tunnel angle in ACL reconstruction: two-dimensional versus three-dimensional guide technique.

Authors:  Jeff R S Leiter; Nevin de Korompay; Lindsey Macdonald; Sheila McRae; Warren Froese; Peter B Macdonald
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-02-03       Impact factor: 4.342

7.  Utility of preoperative distractive stress radiograph for beginners to extent of medial release in total knee arthroplasty.

Authors:  Jae Ang Sim; Ji Hoon Kwak; Sang Hoon Yang; Sung Hoon Moon; Beom Koo Lee; Joon Yub Kim
Journal:  Clin Orthop Surg       Date:  2009-05-30

8.  Varus gonarthrosis predisposes to varus malalignment in TKA.

Authors:  Thomas J Heyse; Ralf Decking; Jack Davis; Friedrich Boettner; Richard S Laskin
Journal:  HSS J       Date:  2009-05-20

9.  Determining knee joint alignment using digital photographs.

Authors:  Holger Schmitt; Hannes Kappel; Michael T Moser; Eloy Cardenas-Montemayor; Karoly Engelleiter; Benita Kuni; Michael Clarius
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-06-13       Impact factor: 4.342

10.  Distal femoral cut in total knee arthroplasty in a Brazilian population.

Authors:  Marcos Areias Vieira Costa; Alan de Paula Mozella; Hugo Alexandre de Araujo Barros Cobra
Journal:  Rev Bras Ortop       Date:  2015-06-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.