Literature DB >> 17437576

A nonfluoroscopic approach for electrophysiology and catheter ablation procedures using a three-dimensional navigation system.

Volkan Tuzcu1.   

Abstract

BACKGROUND: Three-dimensional (3D) electroanatomical navigation systems decrease the fluoroscopy time of electrophysiology and ablation procedures. The aim of this study was to assess the safety and efficacy of a complete nonfluoroscopic approach for electrophysiologic studies and right-sided catheter ablations for supraventricular tachycardia in patients with normal cardiac anatomy using a 3D, surface electrode-based navigation system (NavX, St. Jude Medical, St. Paul, MN, USA). METHODS AND
RESULTS: Electrophysiologic studies were performed in 26 consecutive cases (12.7 +/- 7.5 years) using NavX without fluoroscopy. The procedure time was 98.7 +/- 49.7 minutes. Nonfluoroscopic catheter ablations were performed in 24 of 28 consecutive patients. Cryoablation was used in 23 of 24. The procedure time was 193.5 +/- 80 minutes. The coronary sinus access was obtained in 32.1 +/- 12 (range: 15-60) seconds. No complications occurred. All patients (n = 19) who underwent cryoablation for right-sided arrhythmia substrates with conventional fluoroscopic guidance in addition to NavX were used as a control group (10.1 +/- 5.2 years). Catheter ablation success rate of the control group (16/19, 84%) was not significantly different compared to the patients who underwent ablation without fluoroscopy (22/24, 92%). The procedure time was also not significantly different between the two groups (P = NS).
CONCLUSION: This study demonstrates that nonfluoroscopic electrophysiologic studies and right-sided catheter ablations for supraventricular tachycardia can be safely and effectively performed in the majority of patients with normal cardiac anatomy using NavX. Further studies will be necessary in order to establish the potential utility of NavX in eliminating or decreasing radiation exposure for other electrophysiology procedures.

Entities:  

Mesh:

Year:  2007        PMID: 17437576     DOI: 10.1111/j.1540-8159.2007.00702.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  27 in total

1.  First in vivo use of a capacitive micromachined ultrasound transducer array-based imaging and ablation catheter.

Authors:  Douglas N Stephens; Uyen T Truong; Amin Nikoozadeh; Omer Oralkan; Chi Hyung Seo; Jonathan Cannata; Aaron Dentinger; Kai Thomenius; Alan de la Rama; Tho Nguyen; Feng Lin; Pierre Khuri-Yakub; Aman Mahajan; Kalyanam Shivkumar; Matt O'Donnell; David J Sahn
Journal:  J Ultrasound Med       Date:  2012-02       Impact factor: 2.153

2.  The effect of NavX on fluoroscopy times in pediatric catheter ablation.

Authors:  Wilson Kwong; Andrea L Neilson; Christine C Chiu; Gil J Gross; Robert M Hamilton; Luc Soucie; Elizabeth A Stephenson; Joel A Kirsh
Journal:  J Interv Card Electrophysiol       Date:  2011-10-18       Impact factor: 1.900

3.  Electroanatomic Mapping-Guided Catheter Ablation of Supraventricular Tachycardia in Children with Ebstein's Anomaly.

Authors:  Yakup Ergul; Serhat Koca; Celal Akdeniz; Volkan Tuzcu
Journal:  Pediatr Cardiol       Date:  2018-06-07       Impact factor: 1.655

4.  Successful cryoablation of Mahaim tachycardia in a child with Ebstein's anomaly.

Authors:  Yakup Ergul; Celal Akdeniz; Neslihan Kiplapinar; Volkan Tuzcu
Journal:  Pediatr Cardiol       Date:  2012-07-18       Impact factor: 1.655

5.  Factors associated with fluoroscopy exposure during pediatric catheter ablation utilizing electroanatomical mapping.

Authors:  Grace Wan; Kevin M Shannon; Jeremy P Moore
Journal:  J Interv Card Electrophysiol       Date:  2012-08-02       Impact factor: 1.900

6.  [Interventional therapy of tachyarrhythmias in the pediatric population].

Authors:  Gabriele Hessling
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2014-08-23

7.  Nonfluoroscopic and radiation-limited ablation of ventricular arrhythmias in children and young adults: a case series.

Authors:  Nicholas H Von Bergen; Shalabh Bansal; Jean Gingerich; Ian H Law
Journal:  Pediatr Cardiol       Date:  2011-03-27       Impact factor: 1.655

8.  Catheter Ablation Without Fluoroscopy: Current Techniques And Future Direction.

Authors:  Amee M Bigelow; Grace Smith; John M Clark
Journal:  J Atr Fibrillation       Date:  2014-04-30

9.  Catheter ablation of atrial fibrillation without fluoroscopy using intracardiac echocardiography and electroanatomic mapping.

Authors:  John D Ferguson; Adam Helms; J Michael Mangrum; Srijoy Mahapatra; Pamela Mason; Ken Bilchick; George McDaniel; David Wiggins; John P DiMarco
Journal:  Circ Arrhythm Electrophysiol       Date:  2009-12

10.  Radiation safety protocol using real-time dose reporting reduces patient exposure in pediatric electrophysiology procedures.

Authors:  Akash R Patel; Jamie Ganley; Xiaowei Zhu; Jonathan J Rome; Maully Shah; Andrew C Glatz
Journal:  Pediatr Cardiol       Date:  2014-05-07       Impact factor: 1.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.