Literature DB >> 22006437

The effect of NavX on fluoroscopy times in pediatric catheter ablation.

Wilson Kwong1, Andrea L Neilson, Christine C Chiu, Gil J Gross, Robert M Hamilton, Luc Soucie, Elizabeth A Stephenson, Joel A Kirsh.   

Abstract

PURPOSE: Catheter ablation is the established curative therapy for pediatric tachyarrhythmias. However, exposure to ionizing radiation from fluoroscopy during the procedure is of concern to both patients and caregivers. We sought to assess the impact of an impedance-based three-dimensional navigation system (NavX(TM), Endocardial Solutions, Inc., St. Paul, MN) on pediatric catheter ablation procedures.
METHODS: We retrospectively analyzed procedural data during a 7-year period (2002-2008), which spanned the transition between standard fluoroscopic mapping and adoption of NavX(TM) mapping for catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT) and right/left-sided accessory pathways (RAP/LAP). Comparisons of total procedure time, total fluoroscopy time, and ablation fluoroscopy time (from insertion of ablation catheter until completion of procedure) between NavX(TM) and conventional mapping were made.
RESULTS: Three hundred eighty-eight patients (aged 1-18 years, M/F 236:183) underwent ablation of AVNRT (n = 101), LAP (n = 130), or RAP (n = 157) using either conventional (n = 70) or NavX(TM) (n = 318) mapping. Overall success rates were similar between the two mapping approaches (95.7% for conventional versus 95.9% for NavX(TM)). NavX(TM) mapping significantly reduced ablation fluoroscopy time (15.9 ± 14.3 versus 11.0 ± 8.9 min for NavX(TM), p < 0.01) with a trend towards a decrease in total fluoroscopy time (26.4 ± 15.6 versus 23.8 ± 11.1 min for NavX(TM), p = 0.095). Total procedure time was not significantly different between the two methods (210.1 ± 66 versus 222.8 ± 61 min for NavX(TM), p = 0.13). When analyzed by arrhythmia substrate, there were significant reductions in ablation fluoroscopy time for both LAP and RAP.
CONCLUSIONS: NavX(TM) mapping reduced ablation fluoroscopy times for accessory pathways during pediatric catheter ablation.

Entities:  

Mesh:

Year:  2011        PMID: 22006437     DOI: 10.1007/s10840-011-9604-y

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  22 in total

Review 1.  Fluoroscopy: patient radiation exposure issues.

Authors:  M Mahesh
Journal:  Radiographics       Date:  2001 Jul-Aug       Impact factor: 5.333

2.  A novel nonfluoroscopic catheter visualization system (LocaLisa) to reduce radiation exposure during catheter ablation of supraventricular tachycardias.

Authors:  Paulus Kirchhof; Peter Loh; Lars Eckardt; Michael Ribbing; Sascha Rolf; Olaf Eick; Fred Wittkampf; Martin Borggrefe; G ünter Breithardt G; Wilhelm Haverkamp
Journal:  Am J Cardiol       Date:  2002-08-01       Impact factor: 2.778

3.  Elimination of fluoroscopy use in a pediatric electrophysiology laboratory utilizing three-dimensional mapping.

Authors:  Grace Smith; John M Clark
Journal:  Pacing Clin Electrophysiol       Date:  2007-04       Impact factor: 1.976

Review 4.  Fluoroscopy and the skin: implications for radiofrequency catheter ablation.

Authors:  G T Nahass
Journal:  Am J Cardiol       Date:  1995-07-15       Impact factor: 2.778

5.  Nonfluoroscopic catheter navigation for radiofrequency catheter ablation of supraventricular tachycardia in children.

Authors:  John Papagiannis; Alexandros Tsoutsinos; George Kirvassilis; Ioanna Sofianidou; Theofili Koussi; Cleo Laskari; Maria Kiaffas; Sotiria Apostolopoulou; Spyridon Rammos
Journal:  Pacing Clin Electrophysiol       Date:  2006-09       Impact factor: 1.976

6.  Noncontact mapping-guided ablation of atrial flutter and enhanced-density mapping of the inferior vena caval-tricuspid annulus isthmus.

Authors:  M A Schneider; G Ndrepepa; B Zrenner; M R Karch; S Schmieder; I Deisenhofer; J Schreieck; A Schömig; C Schmitt
Journal:  Pacing Clin Electrophysiol       Date:  2001-12       Impact factor: 1.976

7.  Radiation exposure during catheter ablation of atrial fibrillation.

Authors:  Lars Lickfett; Mahadevappa Mahesh; Chandra Vasamreddy; David Bradley; Vinod Jayam; Zayd Eldadah; Timm Dickfeld; Deborah Kearney; Darshan Dalal; Berndt Lüderitz; Ronald Berger; Hugh Calkins
Journal:  Circulation       Date:  2004-10-25       Impact factor: 29.690

8.  Electromagnetic versus fluoroscopic mapping of the inferior isthmus for ablation of typical atrial flutter: A prospective randomized study.

Authors:  H Kottkamp; B Hügl; B Krauss; U Wetzel; A Fleck; G Schuler; G Hindricks
Journal:  Circulation       Date:  2000-10-24       Impact factor: 29.690

9.  Acute radiation dermatitis following radiofrequency catheter ablation of atrioventricular nodal reentrant tachycardia.

Authors:  L S Rosenthal; T J Beck; J Williams; M Mahesh; M G Herman; J L Dinerman; H Calkins; J H Lawrence
Journal:  Pacing Clin Electrophysiol       Date:  1997-07       Impact factor: 1.976

10.  Prospective assessment after pediatric cardiac ablation: demographics, medical profiles, and initial outcomes.

Authors:  George F Van Hare; Harold Javitz; Dorit Carmelli; J Philip Saul; Ronn E Tanel; Peter S Fischbach; Ronald J Kanter; Michael Schaffer; Ann Dunnigan; Steven Colan; Gerald Serwer
Journal:  J Cardiovasc Electrophysiol       Date:  2004-07
View more
  8 in total

1.  A Cost-Effective Analysis of Systematically Using Mapping Systems During Catheter Ablation Procedures in Children and Teenagers.

Authors:  Massimiliano Marini; Daniele Ravanelli; Fabrizio Guarracini; Maurizio Del Greco; Silvia Quintarelli; Anna Cima; Alessio Coser; Marta Martin; Aldo Valentini; Roberto Bonmassari
Journal:  Pediatr Cardiol       Date:  2018-06-12       Impact factor: 1.655

2.  Zero and Minimal Fluoroscopic Approaches During Ablation of Supraventricular Tachycardias: A Systematic Review and Meta-Analysis.

Authors:  Dorottya Debreceni; Kristof Janosi; Mate Vamos; Andras Komocsi; Tamas Simor; Peter Kupo
Journal:  Front Cardiovasc Med       Date:  2022-04-11

3.  Radiation safety protocol using real-time dose reporting reduces patient exposure in pediatric electrophysiology procedures.

Authors:  Akash R Patel; Jamie Ganley; Xiaowei Zhu; Jonathan J Rome; Maully Shah; Andrew C Glatz
Journal:  Pediatr Cardiol       Date:  2014-05-07       Impact factor: 1.655

4.  The Benefit of a General, Systematic Use of Mapping Systems During Electrophysiological Procedures in Children and Teenagers: The Experience of an Adult EP Laboratory.

Authors:  Massimiliano Marini; Maurizio Del Greco; Daniele Ravanelli; Anna Cima; Alessio Coser; Giulio Porcedda; Fabrizio Guarracini; Aldo Valentini; Roberto Bonmassari
Journal:  Pediatr Cardiol       Date:  2016-03-01       Impact factor: 1.655

5.  Getting to zero: impact of electroanatomical mapping on fluoroscopy use in pediatric catheter ablation.

Authors:  Bradley C Clark; Kohei Sumihara; Robert McCarter; Charles I Berul; Jeffrey P Moak
Journal:  J Interv Card Electrophysiol       Date:  2016-01-15       Impact factor: 1.900

Review 6.  A systematic review of the effectiveness of catheter ablation NavX mapping system for treatment of the cardiac arrhythmia.

Authors:  Mohammadreza Mobinizadeh; Jalal Arabloo; Pejman Hamouzadeh; Ali Akbari Sari
Journal:  Med J Islam Repub Iran       Date:  2015-03-10

7.  Extensive Use of 3D Nonfluoroscopic Mapping Systems for Reducing Radiation Exposure during Catheter Ablation Procedures: An Analysis of 10 Years of Activity.

Authors:  Massimiliano Marini; Marta Martin; Daniele Ravanelli; Maurizio Del Greco; Silvia Quintarelli; Fabrizio Guarracini; Alessio Coser; Aldo Valentini; Roberto Bonmassari
Journal:  Biomed Res Int       Date:  2019-03-10       Impact factor: 3.411

8.  Near zerO fluoroscopic exPosure during catheter ablAtion of supRavenTricular arrhYthmias: the NO-PARTY multicentre randomized trial.

Authors:  Michela Casella; Antonio Dello Russo; Gemma Pelargonio; Maurizio Del Greco; Gianluca Zingarini; Marcello Piacenti; Andrea Di Cori; Victor Casula; Massimiliano Marini; Francesca Pizzamiglio; Martina Zucchetti; Stefania Riva; Eleonora Russo; Maria Lucia Narducci; Ezio Soldati; Luca Panchetti; Umberto Startari; Gianluigi Bencardino; Francesco Perna; Pasquale Santangeli; Luigi Di Biase; Fabrizio Cichocki; Giovanni Fattore; Mariagrazia Bongiorni; Eugenio Picano; Andrea Natale; Claudio Tondo
Journal:  Europace       Date:  2015-11-10       Impact factor: 5.214

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.