Literature DB >> 24801673

Radiation safety protocol using real-time dose reporting reduces patient exposure in pediatric electrophysiology procedures.

Akash R Patel1, Jamie Ganley, Xiaowei Zhu, Jonathan J Rome, Maully Shah, Andrew C Glatz.   

Abstract

Radiation exposure during pediatric catheterization is significant. We sought to describe radiation exposure and the effectiveness of radiation safety protocols in reducing exposure during catheter ablations with electrophysiology studies in children and patients with congenital heart disease. We additionally sought to identify at-risk patients. We retrospectively reviewed all interventional electrophysiology procedures performed from April 2009 to September 2011 (6 months preceding intervention, 12 months following implementation of initial radiation safety protocol, and 8 months following implementation of modified protocol). The protocols consisted of low pulse rate fluoroscopy settings, operator notification of skin entrance dose every 1,000 mGy, adjusting cameras by >5 at every 1,000 mGy, and appropriate collimation. The cohort consisted of 291 patients (70 pre-intervention, 137 after initial protocol implementation, 84 after modified protocol implementation) at a median age of 14.9 years with congenital heart disease present in 11 %. Diagnoses included atrioventricular nodal reentrant tachycardia (25 %), atrioventricular reentrant tachycardia (61 %), atrial tachycardias (12 %), and ventricular tachycardia (2 %). There were no differences between groups based on patient, arrhythmia, and procedural characteristics. Following implementation of the protocols, there were significant reductions in all measures of radiation exposure: fluoroscopy time (17.8 %), dose area product (80.2 %), skin entry dose (81.0 %), and effective dose (76.9 %), p = 0.0001. Independent predictors of increased radiation exposure included larger patient weight, longer fluoroscopy time, and lack of radiation safety protocol. Implementation of a radiation safety protocol for pediatric and congenital catheter ablations can drastically reduce radiation exposure to patients without affecting procedural success.

Entities:  

Mesh:

Year:  2014        PMID: 24801673     DOI: 10.1007/s00246-014-0904-8

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  31 in total

1.  Use of angiographic CT imaging in the cardiac catheterization laboratory for congenital heart disease.

Authors:  Andrew C Glatz; Xiaowei Zhu; Matthew J Gillespie; Brian D Hanna; Jonathan J Rome
Journal:  JACC Cardiovasc Imaging       Date:  2010-11

2.  Mapping and ablation of atypical flutter in congenital heart disease with a novel three-dimensional mapping system (Carto Merge).

Authors:  Andreas Pflaumer; Isabel Deisenhofer; Jörg Hausleiter; Bernhard Zrenner
Journal:  Europace       Date:  2006-01-09       Impact factor: 5.214

3.  Elimination of fluoroscopy use in a pediatric electrophysiology laboratory utilizing three-dimensional mapping.

Authors:  Grace Smith; John M Clark
Journal:  Pacing Clin Electrophysiol       Date:  2007-04       Impact factor: 1.976

4.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

5.  Vasorelaxation induced by vascular endothelial growth factor in the human internal mammary artery and radial artery.

Authors:  Wei Wei; Zhi-Wu Chen; Qin Yang; Hongkui Jin; Anthony Furnary; Xiao-Qiang Yao; Anthony P C Yim; Guo-Wei He
Journal:  Vascul Pharmacol       Date:  2006-10-27       Impact factor: 5.773

6.  Pediatric radiofrequency catheter ablation registry success, fluoroscopy time, and complication rate for supraventricular tachycardia: comparison of early and recent eras.

Authors:  John D Kugler; David A Danford; Kris A Houston; Gary Felix
Journal:  J Cardiovasc Electrophysiol       Date:  2002-04

7.  Nonfluoroscopic catheter navigation for radiofrequency catheter ablation of supraventricular tachycardia in children.

Authors:  John Papagiannis; Alexandros Tsoutsinos; George Kirvassilis; Ioanna Sofianidou; Theofili Koussi; Cleo Laskari; Maria Kiaffas; Sotiria Apostolopoulou; Spyridon Rammos
Journal:  Pacing Clin Electrophysiol       Date:  2006-09       Impact factor: 1.976

8.  Prospective assessment after pediatric cardiac ablation: demographics, medical profiles, and initial outcomes.

Authors:  George F Van Hare; Harold Javitz; Dorit Carmelli; J Philip Saul; Ronn E Tanel; Peter S Fischbach; Ronald J Kanter; Michael Schaffer; Ann Dunnigan; Steven Colan; Gerald Serwer
Journal:  J Cardiovasc Electrophysiol       Date:  2004-07

9.  Estimation of children's radiation dose from cardiac catheterisations, performed for the diagnosis or the treatment of a congenital heart disease using TLD dosimetry and Monte Carlo simulation.

Authors:  E N Yakoumakis; G I Gialousis; Despina Papadopoulou; Triantafillia Makri; Zografia Pappouli; Nikolaos Yakoumakis; Panayotis Papagiannis; Evangelos Georgiou
Journal:  J Radiol Prot       Date:  2009-05-19       Impact factor: 1.394

10.  Exclusion of fluoroscopy during ablation treatment of right accessory pathway in children.

Authors:  Fabrizio Drago; Massimo Stefano Silvetti; Alfredo Di Pino; Giorgia Grutter; Maurizio Bevilacqua; Shoshana Leibovich
Journal:  J Cardiovasc Electrophysiol       Date:  2002-08
View more
  3 in total

1.  The Benefit of a General, Systematic Use of Mapping Systems During Electrophysiological Procedures in Children and Teenagers: The Experience of an Adult EP Laboratory.

Authors:  Massimiliano Marini; Maurizio Del Greco; Daniele Ravanelli; Anna Cima; Alessio Coser; Giulio Porcedda; Fabrizio Guarracini; Aldo Valentini; Roberto Bonmassari
Journal:  Pediatr Cardiol       Date:  2016-03-01       Impact factor: 1.655

2.  A novel dosimeter for measuring the amount of radiation exposure of surgeons during percutaneous nephrolithotomy: Instadose™.

Authors:  Emrah Yuruk; Gokhan Gureser; Murat Tuken; Kasim Ertas; Ege Can Serefoglu
Journal:  Cent European J Urol       Date:  2016-06-20

3.  Evaluation of a new very low dose imaging protocol: feasibility and impact on X-ray dose levels in electrophysiology procedures.

Authors:  Felix Bourier; Tilko Reents; Sonia Ammar-Busch; Alessandra Buiatti; Marc Kottmaier; Verena Semmler; Marta Telishevska; Amir Brkic; Christian Grebmer; Carsten Lennerz; Christof Kolb; Gabriele Hessling; Isabel Deisenhofer
Journal:  Europace       Date:  2015-11-20       Impact factor: 5.214

  3 in total