Literature DB >> 22298868

First in vivo use of a capacitive micromachined ultrasound transducer array-based imaging and ablation catheter.

Douglas N Stephens1, Uyen T Truong, Amin Nikoozadeh, Omer Oralkan, Chi Hyung Seo, Jonathan Cannata, Aaron Dentinger, Kai Thomenius, Alan de la Rama, Tho Nguyen, Feng Lin, Pierre Khuri-Yakub, Aman Mahajan, Kalyanam Shivkumar, Matt O'Donnell, David J Sahn.   

Abstract

OBJECTIVES: The primary objective was to test in vivo for the first time the general operation of a new multifunctional intracardiac echocardiography (ICE) catheter constructed with a microlinear capacitive micromachined ultrasound transducer (ML-CMUT) imaging array. Secondarily, we examined the compatibility of this catheter with electroanatomic mapping (EAM) guidance and also as a radiofrequency ablation (RFA) catheter. Preliminary thermal strain imaging (TSI)-derived temperature data were obtained from within the endocardium simultaneously during RFA to show the feasibility of direct ablation guidance procedures.
METHODS: The new 9F forward-looking ICE catheter was constructed with 3 complementary technologies: a CMUT imaging array with a custom electronic array buffer, catheter surface electrodes for EAM guidance, and a special ablation tip, that permits simultaneous TSI and RFA. In vivo imaging studies of 5 anesthetized porcine models with 5 CMUT catheters were performed.
RESULTS: The ML-CMUT ICE catheter provided high-resolution real-time wideband 2-dimensional (2D) images at greater than 8 MHz and is capable of both RFA and EAM guidance. Although the 24-element array aperture dimension is only 1.5 mm, the imaging depth of penetration is greater than 30 mm. The specially designed ultrasound-compatible metalized plastic tip allowed simultaneous imaging during ablation and direct acquisition of TSI data for tissue ablation temperatures. Postprocessing analysis showed a first-order correlation between TSI and temperature, permitting early development temperature-time relationships at specific myocardial ablation sites.
CONCLUSIONS: Multifunctional forward-looking ML-CMUT ICE catheters, with simultaneous intracardiac guidance, ultrasound imaging, and RFA, may offer a new means to improve interventional ablation procedures.

Entities:  

Mesh:

Year:  2012        PMID: 22298868      PMCID: PMC3420825          DOI: 10.7863/jum.2012.31.2.247

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  49 in total

1.  Elimination of fluoroscopy use in a pediatric electrophysiology laboratory utilizing three-dimensional mapping.

Authors:  Grace Smith; John M Clark
Journal:  Pacing Clin Electrophysiol       Date:  2007-04       Impact factor: 1.976

2.  Inducing and imaging thermal strain using a single ultrasound linear array.

Authors:  Sheng-Wen Huang; Kang Kim; Russell S Witte; Ragnar Olafsson; Matthew O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-09       Impact factor: 2.725

3.  On the use of CartoSound for left atrial navigation.

Authors:  David Schwartzman; Hua Zhong
Journal:  J Cardiovasc Electrophysiol       Date:  2009-12-21

4.  Radiation doses during pediatric radiofrequency catheter ablation procedures.

Authors:  R A Geise; N E Peters; A Dunnigan; S Milstein
Journal:  Pacing Clin Electrophysiol       Date:  1996-11       Impact factor: 1.976

5.  Predictors of fluoroscopy time and estimated radiation exposure during radiofrequency catheter ablation procedures.

Authors:  L S Rosenthal; M Mahesh; T J Beck; J P Saul; J M Miller; N Kay; L S Klein; S Huang; P Gillette; E Prystowsky; M Carlson; R D Berger; J H Lawrence; P Yong; H Calkins
Journal:  Am J Cardiol       Date:  1998-08-15       Impact factor: 2.778

6.  Catheter ablation of atrial fibrillation without fluoroscopy using intracardiac echocardiography and electroanatomic mapping.

Authors:  John D Ferguson; Adam Helms; J Michael Mangrum; Srijoy Mahapatra; Pamela Mason; Ken Bilchick; George McDaniel; David Wiggins; John P DiMarco
Journal:  Circ Arrhythm Electrophysiol       Date:  2009-12

7.  Intracardiac echocardiography during interventional procedures.

Authors:  Sophia Vaina; Jurgen Ligthart; Maniyal Vijayakumar; Folkert J Ten Cate; Maarten Witsenburg; Luc J Jordaens; George Sianos; Andrew S Thornton; Marcoen F Scholten; Peter de Jaegere; Patrick W Serruys
Journal:  EuroIntervention       Date:  2006-02       Impact factor: 6.534

8.  Exclusion of fluoroscopy during ablation treatment of right accessory pathway in children.

Authors:  Fabrizio Drago; Massimo Stefano Silvetti; Alfredo Di Pino; Giorgia Grutter; Maurizio Bevilacqua; Shoshana Leibovich
Journal:  J Cardiovasc Electrophysiol       Date:  2002-08

Review 9.  Pulmonary vein stenosis complicating ablation for atrial fibrillation: clinical spectrum and interventional considerations.

Authors:  David R Holmes; Kristi H Monahan; Douglas Packer
Journal:  JACC Cardiovasc Interv       Date:  2009-04       Impact factor: 11.195

10.  Transvascular intracardiac applications of a miniaturized phased-array ultrasonic endoscope. Initial experience with intracardiac imaging in piglets.

Authors:  L M Valdes-Cruz; E Sideris; D J Sahn; A Murillo-Olivas; O Knudson; R Omoto; S Kyo; R Gulde
Journal:  Circulation       Date:  1991-03       Impact factor: 29.690

View more
  5 in total

1.  Integrated RFA/PSOCT catheter for real-time guidance of cardiac radio-frequency ablation.

Authors:  Xiaowei Zhao; Xiaoyong Fu; Colin Blumenthal; Yves T Wang; Michael W Jenkins; Christopher Snyder; Mauricio Arruda; Andrew M Rollins
Journal:  Biomed Opt Express       Date:  2018-11-20       Impact factor: 3.732

Review 2.  Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy.

Authors:  Kullervo Hynynen; Ryan M Jones
Journal:  Phys Med Biol       Date:  2016-08-05       Impact factor: 3.609

3.  Single-chip CMUT-on-CMOS front-end system for real-time volumetric IVUS and ICE imaging.

Authors:  Gokce Gurun; Coskun Tekes; Jaime Zahorian; Toby Xu; Sarp Satir; Mustafa Karaman; Jennifer Hasler; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-02       Impact factor: 2.725

4.  New Endoscopic Imaging Technology Based on MEMS Sensors and Actuators.

Authors:  Zhen Qiu; Wibool Piyawattanamatha
Journal:  Micromachines (Basel)       Date:  2017-07-02       Impact factor: 2.891

Review 5.  Advances in Capacitive Micromachined Ultrasonic Transducers.

Authors:  Kevin Brenner; Arif Sanli Ergun; Kamyar Firouzi; Morten Fischer Rasmussen; Quintin Stedman; Butrus Pierre Khuri-Yakub
Journal:  Micromachines (Basel)       Date:  2019-02-23       Impact factor: 2.891

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.