Literature DB >> 17437109

Ideal entry point for the thoracic pedicle screw during the free hand technique.

Kook Jin Chung1, Seung Woo Suh, Sameer Desai, Hae Ryong Song.   

Abstract

We have attempted to determine the spatial orientation of the base of the superior articular process in relation to the centre of the pedicle and then measure the transverse and sagittal screw angles using this ideal pedicle screw entry point - the base of the superior articular process at the junction of the lateral one-third and medial two-thirds. The proposed advantages of this technique are the easily identifiable entry point, the well-defined transverse and sagittal screw angles and a very low incidence of medial and inferior pedicle violation.

Mesh:

Year:  2007        PMID: 17437109      PMCID: PMC2551718          DOI: 10.1007/s00264-007-0363-4

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  19 in total

1.  The accuracy of pedicle screw placement in the thoracic spine using the "Funnel Technique": part 1. A cadaveric study.

Authors:  Wicharn Yingsakmonkol; Eldin Karaikovic; Robert W Gaines
Journal:  J Spinal Disord Tech       Date:  2002-12

2.  Thoracic pedicle morphometry in vertebrae from scoliotic spines.

Authors:  Stefan Parent; Hubert Labelle; Wafa Skalli; Jacques de Guise
Journal:  Spine (Phila Pa 1976)       Date:  2004-02-01       Impact factor: 3.468

3.  Experimental pullout testing and comparison of variables in transpedicular screw fixation. A biomechanical study.

Authors:  R Skinner; J Maybee; E Transfeldt; R Venter; W Chalmers
Journal:  Spine (Phila Pa 1976)       Date:  1990-03       Impact factor: 3.468

4.  Analysis of the morphometric characteristics of the thoracic and lumbar pedicles.

Authors:  M R Zindrick; L L Wiltse; A Doornik; E H Widell; G W Knight; A G Patwardhan; J C Thomas; S L Rothman; B T Fields
Journal:  Spine (Phila Pa 1976)       Date:  1987-03       Impact factor: 3.468

5.  Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation.

Authors:  M H Krag; D L Weaver; B D Beynnon; L D Haugh
Journal:  Spine (Phila Pa 1976)       Date:  1988-01       Impact factor: 3.468

6.  Thoracic pedicle screw fixation in spinal deformities: are they really safe?

Authors:  S I Suk; W J Kim; S M Lee; J H Kim; E R Chung
Journal:  Spine (Phila Pa 1976)       Date:  2001-09-15       Impact factor: 3.468

7.  Pullout strength of pedicle screws versus pedicle and laminar hooks in the thoracic spine.

Authors:  U Liljenqvist; L Hackenberg; T Link; H Halm
Journal:  Acta Orthop Belg       Date:  2001-04       Impact factor: 0.500

8.  Placement of pedicle screws in the thoracic spine. Part I: Morphometric analysis of the thoracic vertebrae.

Authors:  A R Vaccaro; S J Rizzolo; T J Allardyce; M Ramsey; J Salvo; R A Balderston; J M Cotler
Journal:  J Bone Joint Surg Am       Date:  1995-08       Impact factor: 5.284

9.  Use of the anatomic trajectory for thoracic pedicle screw salvage after failure/violation using the straight-forward technique: a biomechanical analysis.

Authors:  Ronald A Lehman; Timothy R Kuklo
Journal:  Spine (Phila Pa 1976)       Date:  2003-09-15       Impact factor: 3.468

10.  Free hand pedicle screw placement in the thoracic spine: is it safe?

Authors:  Yongjung J Kim; Lawrence G Lenke; Keith H Bridwell; Yongsun S Cho; K Daniel Riew
Journal:  Spine (Phila Pa 1976)       Date:  2004-02-01       Impact factor: 3.468

View more
  15 in total

1.  Are computer numerical control (CNC)-manufactured patient-specific metal templates available for posterior thoracic pedicle screw insertion? Feasibility and accuracy evaluation.

Authors:  Xiangxue Kong; Lei Tang; Qiang Ye; Wenhua Huang; Jianyi Li
Journal:  Eur Spine J       Date:  2017-07-17       Impact factor: 3.134

Review 2.  Pedicle screw insertion techniques: an update and review of the literature.

Authors:  F Perna; R Borghi; F Pilla; N Stefanini; A Mazzotti; M Chehrassan
Journal:  Musculoskelet Surg       Date:  2016-11-19

3.  Head-mounted display augmented reality to guide pedicle screw placement utilizing computed tomography.

Authors:  Jacob T Gibby; Samuel A Swenson; Steve Cvetko; Raj Rao; Ramin Javan
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-06-22       Impact factor: 2.924

4.  Morphologic evaluation of the thoracic vertebrae for safe free-hand pedicle screw placement in adolescent idiopathic scoliosis: a CT-based anatomical study.

Authors:  Guanyu Cui; Kota Watanabe; Naobumi Hosogane; Takashi Tsuji; Ken Ishii; Masaya Nakamura; Yoshiaki Toyama; Kazuhiro Chiba; Lawrence G Lenke; Morio Matsumoto
Journal:  Surg Radiol Anat       Date:  2011-07-08       Impact factor: 1.246

Review 5.  [Adolescent idiopathic scoliosis : Guideline for practical application].

Authors:  J Seifert; F Thielemann; P Bernstein
Journal:  Orthopade       Date:  2016-06       Impact factor: 1.087

Review 6.  Techniques and accuracy of thoracolumbar pedicle screw placement.

Authors:  Varun Puvanesarajah; Jason A Liauw; Sheng-Fu Lo; Ioan A Lina; Timothy F Witham
Journal:  World J Orthop       Date:  2014-04-18

7.  Accuracy of thoracic pedicle screw using ideal pedicle entry point in severe scoliosis.

Authors:  Hitesh N Modi; Seung-Woo Suh; Jae-Young Hong; Jae-Hyuk Yang
Journal:  Clin Orthop Relat Res       Date:  2010-02-25       Impact factor: 4.176

8.  Free-hand pedicle screws insertion technique in the treatment of 120 consecutive scoliosis cases operated without use of intraoperative neurophysiological monitoring.

Authors:  Marco Crostelli; Osvaldo Mazza; Massimo Mariani
Journal:  Eur Spine J       Date:  2012-03-13       Impact factor: 3.134

9.  Accuracy of thoracic pedicle screw placement in scoliosis using the ideal pedicle entry point during the freehand technique.

Authors:  Hitesh Modi; Seung Woo Suh; Hae-Ryong Song; Jae-Hyuk Yang
Journal:  Int Orthop       Date:  2008-03-21       Impact factor: 3.075

10.  Accuracy and safety of pedicle screw placement in neuromuscular scoliosis with free-hand technique.

Authors:  Hitesh N Modi; Seung Woo Suh; Harry Fernandez; Jae Hyuk Yang; Hae-Ryong Song
Journal:  Eur Spine J       Date:  2008-10-01       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.