Literature DB >> 17418474

Accuracy of contacts calculated from 3D images of occlusal surfaces.

R DeLong1, S Knorr, G C Anderson, J Hodges, M R Pintado.   

Abstract

OBJECTIVES: Compare occlusal contacts calculated from 3D virtual models created from clinical records to contacts identified clinically using shimstock and transillumination.
METHODS: Upper and lower full arch alginate impressions and vinyl polysiloxane centric interocclusal records were made of 12 subjects. Stone casts made from the alginate impressions and the interocclusal records were optically scanned. Three-dimensional virtual models of the dental arches and interocclusal records were constructed using the Virtual Dental Patient Software. Contacts calculated from the virtual interocclusal records and from the aligned upper and lower virtual arch models were compared to those identified clinically using 0.01mm shimstock and transillumination of the interocclusal record. Virtual contacts and transillumination contacts were compared by anatomical region and by contacting tooth pairs to shimstock contacts. Because there is no accepted standard for identifying occlusal contacts, methods were compared in pairs with one labeled "standard" and the second labeled "test". Accuracy was defined as the number of contacts and non-contacts of the "test" that were in agreement with the "standard" divided by the total number of contacts and non-contacts of the "standard".
RESULTS: Accuracy of occlusal contacts calculated from virtual interocclusal records and aligned virtual casts compared to transillumination were: 0.87+/-0.05 and 0.84+/-0.06 by region and 0.95+/-0.07 and 0.95+/-0.05 by tooth, respectively. Comparisons with shimstock were: 0.85+/-0.15 (record), 0.84+/-0.14 (casts), and 81+/-17 (transillumination).
CONCLUSIONS: The virtual record, aligned virtual arches, and transillumination methods of identifying contacts are equivalent, and show better agreement with each other than with the shimstock method.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17418474      PMCID: PMC2041880          DOI: 10.1016/j.jdent.2007.02.004

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  24 in total

1.  Influence of clenching intensity on bite force balance, occlusal contact area, and average bite pressure.

Authors:  O Hidaka; M Iwasaki; M Saito; T Morimoto
Journal:  J Dent Res       Date:  1999-07       Impact factor: 6.116

2.  Occlusal force distribution on the dental arch during various levels of clenching.

Authors:  H Kumagai; T Suzuki; T Hamada; P Sondang; M Fujitani; H Nikawa
Journal:  J Oral Rehabil       Date:  1999-12       Impact factor: 3.837

3.  An evaluation of occlusal contact marking indicators. A descriptive quantitative method.

Authors:  P Millstein; A Maya
Journal:  J Am Dent Assoc       Date:  2001-09       Impact factor: 3.634

4.  Comparing maximum intercuspal contacts of virtual dental patients and mounted dental casts.

Authors:  Ralph Delong; Ching-Chang Ko; Gary C Anderson; James S Hodges; W H Douglas
Journal:  J Prosthet Dent       Date:  2002-12       Impact factor: 3.426

5.  Masticatory performance and areas of occlusal contact and near contact in subjects with normal occlusion and malocclusion.

Authors:  Shannon Owens; Peter H Buschang; Gaylord S Throckmorton; Leslea Palmer; Jeryl English
Journal:  Am J Orthod Dentofacial Orthop       Date:  2002-06       Impact factor: 2.650

6.  Thickness, strength, and plastic deformation of occlusal registration strips.

Authors:  G C Halperin; A R Halperin; B K Norling
Journal:  J Prosthet Dent       Date:  1982-11       Impact factor: 3.426

7.  A method for in vivo quantitative occlusal strain and stress analysis.

Authors:  M Arcan; F Zandman
Journal:  J Biomech       Date:  1984       Impact factor: 2.712

8.  Attaining harmonic occlusion through visualized strain analysis.

Authors:  P E Dawson; M Arcan
Journal:  J Prosthet Dent       Date:  1981-12       Impact factor: 3.426

9.  The relationship of occlusal wear to occlusal contact area.

Authors:  M D Russell; A A Grant
Journal:  J Oral Rehabil       Date:  1983-09       Impact factor: 3.837

10.  Influence of clenching level on intercuspal contact area in various regions of the dental arch.

Authors:  W Gurdsapsri; M Ai; K Baba; K Fueki
Journal:  J Oral Rehabil       Date:  2000-03       Impact factor: 3.837

View more
  10 in total

1.  Digital 3D image of bimaxillary casts connected by a vestibular scan.

Authors:  Susanne Wriedt; Irene Schmidtmann; Mareike Niemann; Heinrich Wehrbein
Journal:  J Orofac Orthop       Date:  2013-06-28       Impact factor: 1.938

2.  Precision of the virtual occlusal record.

Authors:  Keyan P Botsford; Michael C Frazier; Ahmed A M Ghoneima; Achint Utreja; Surya S Bhamidipalli; Kelton T Stewart
Journal:  Angle Orthod       Date:  2019-03-28       Impact factor: 2.079

3.  [Accuracy of intercuspal occlusion in 3D reconstruction with the dental articulator position method].

Authors:  L L Li; Y J Zhao; H Chen; Y Wang; Y C Sun
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2020-02-18

4.  Clinical study comparing the accuracy of interocclusal records, digitally obtained by three different devices.

Authors:  Cristina Fraile; Alberto Ferreiroa; Marta Romeo Rubio; Raquel Alonso; Guillermo Pradíes Ramiro
Journal:  Clin Oral Investig       Date:  2022-05-18       Impact factor: 3.606

5.  Clinical occlusion analysis versus semi-adjustable articulator and virtual articulator occlusion analysis.

Authors:  Smaranda Buduru; Emilia Finta; Oana Almasan; Mirela Fluerasu; Manuela Manziuc; Simona Iacob; Cristian Culcitchi; Marius Negucioiu
Journal:  Med Pharm Rep       Date:  2020-07-22

6.  Evaluation of the effectiveness of the new tooth wear measurement parameters.

Authors:  Sang-Hak Lee; Shin-Eun Nam; Seung-Pyo Lee
Journal:  Anat Cell Biol       Date:  2015-12-21

7.  Method to evaluate the noise of 3D intra-oral scanner.

Authors:  Alban Desoutter; Osama Yusuf Solieman; Gérard Subsol; Hervé Tassery; Frédéric Cuisinier; Michel Fages
Journal:  PLoS One       Date:  2017-08-09       Impact factor: 3.240

8.  A novel in vivo method to evaluate trueness of digital impressions.

Authors:  Emad A Albdour; Eman Shaheen; Myrthel Vranckx; Francesco Guido Mangano; Constantinus Politis; Reinhilde Jacobs
Journal:  BMC Oral Health       Date:  2018-07-03       Impact factor: 2.757

9.  Evaluation of biogeneric design techniques with CEREC CAD/CAM system.

Authors:  Yeliz Arslan; Seçil Karakoca Nemli; Merve Bankoğlu Güngör; Evşen Tamam; Handan Yılmaz
Journal:  J Adv Prosthodont       Date:  2015-12-30       Impact factor: 1.904

10.  Comparison of the marginal fit of milled yttrium stabilized zirconium dioxide crowns obtained by scanning silicone impressions and by scanning stone replicas.

Authors:  Estefanía Aranda Yus; Josep Maria Anglada Cantarell; Antonio Miñarro Alonso
Journal:  J Adv Prosthodont       Date:  2018-06-12       Impact factor: 1.904

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.