Literature DB >> 17404459

Organ dose conversion coefficients for voxel models of the reference male and female from idealized photon exposures.

H Schlattl1, M Zankl, N Petoussi-Henss.   

Abstract

A new series of organ equivalent dose conversion coefficients for whole body external photon exposure is presented for a standardized couple of human voxel models, called Rex and Regina. Irradiations from broad parallel beams in antero-posterior, postero-anterior, left- and right-side lateral directions as well as from a 360 degrees rotational source have been performed numerically by the Monte Carlo transport code EGSnrc. Dose conversion coefficients from an isotropically distributed source were computed, too. The voxel models Rex and Regina originating from real patient CT data comply in body and organ dimensions with the currently valid reference values given by the International Commission on Radiological Protection (ICRP) for the average Caucasian man and woman, respectively. While the equivalent dose conversion coefficients of many organs are in quite good agreement with the reference values of ICRP Publication 74, for some organs and certain geometries the discrepancies amount to 30% or more. Differences between the sexes are of the same order with mostly higher dose conversion coefficients in the smaller female model. However, much smaller deviations from the ICRP values are observed for the resulting effective dose conversion coefficients. With the still valid definition for the effective dose (ICRP Publication 60), the greatest change appears in lateral exposures with a decrease in the new models of at most 9%. However, when the modified definition of the effective dose as suggested by an ICRP draft is applied, the largest deviation from the current reference values is obtained in postero-anterior geometry with a reduction of the effective dose conversion coefficient by at most 12%.

Entities:  

Mesh:

Year:  2007        PMID: 17404459     DOI: 10.1088/0031-9155/52/8/006

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

1.  DNA double-strand breaks as potential indicators for the biological effects of ionising radiation exposure from cardiac CT and conventional coronary angiography: a randomised, controlled study.

Authors:  Dominik Geisel; Elke Zimmermann; Matthias Rief; Johannes Greupner; Michael Laule; Fabian Knebel; Bernd Hamm; Marc Dewey
Journal:  Eur Radiol       Date:  2012-04-17       Impact factor: 5.315

2.  Hybrid computational phantoms representing the reference adult male and adult female: construction and applications for retrospective dosimetry.

Authors:  Jorge L Hurtado; Choonsik Lee; Daniel Lodwick; Timothy Goede; Jonathan L Williams; Wesley E Bolch
Journal:  Health Phys       Date:  2012-03       Impact factor: 1.316

3.  Advances in Computational Human Phantoms and Their Applications in Biomedical Engineering - A Topical Review.

Authors:  Wolfgang Kainz; Esra Neufeld; Wesley E Bolch; Christian G Graff; Chan Hyeong Kim; Niels Kuster; Bryn Lloyd; Tina Morrison; Paul Segars; Yeon Soo Yeom; Maria Zankl; X George Xu; Benjamin M W Tsui
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-01

Review 4.  An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history.

Authors:  X George Xu
Journal:  Phys Med Biol       Date:  2014-08-21       Impact factor: 3.609

5.  Determination and verification of the x-ray spectrum of a CT scanner.

Authors:  Ahmad Ibrahim Hassan; Martin Skalej; Helmut Schlattl; Christoph Hoeschen
Journal:  J Med Imaging (Bellingham)       Date:  2018-02-07

6.  RADAR reference adult, pediatric, and pregnant female phantom series for internal and external dosimetry.

Authors:  Michael G Stabin; X George Xu; Mary A Emmons; W Paul Segars; Chengyu Shi; Michael J Fernald
Journal:  J Nucl Med       Date:  2012-09-11       Impact factor: 10.057

7.  RPI-AM and RPI-AF, a pair of mesh-based, size-adjustable adult male and female computational phantoms using ICRP-89 parameters and their calculations for organ doses from monoenergetic photon beams.

Authors:  Juying Zhang; Yong Hum Na; Peter F Caracappa; X George Xu
Journal:  Phys Med Biol       Date:  2009-09-17       Impact factor: 3.609

8.  The profound effects of patient arm positioning on organ doses from CT procedures calculated using Monte Carlo simulations and deformable phantoms.

Authors:  Haikuan Liu; Yiming Gao; Aiping Ding; Peter F Caracappa; X George Xu
Journal:  Radiat Prot Dosimetry       Date:  2014-09-16       Impact factor: 0.972

9.  First steps towards a fast-neutron therapy planning program.

Authors:  Sylvia Garny; Werner Rühm; Maria Zankl; Franz M Wagner; Herwig G Paretzke
Journal:  Radiat Oncol       Date:  2011-11-25       Impact factor: 3.481

10.  NIRS external dose estimation system for Fukushima residents after the Fukushima Dai-ichi NPP accident.

Authors:  Keiichi Akahane; Shunsuke Yonai; Shigekazu Fukuda; Nobuyuki Miyahara; Hiroshi Yasuda; Kazuki Iwaoka; Masaki Matsumoto; Akifumi Fukumura; Makoto Akashi
Journal:  Sci Rep       Date:  2013       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.