Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance.

Hanan Keren1, Daniel Burkhoff, Pierre Squara.   

Abstract

Noninvasive cardiac output (CO) measurement can be useful in many clinical settings where invasive monitoring is not desired. Bioimpedance (intrabeat measurement of changes in transthoracic voltage amplitude in response to an injected high-frequency current) has been explored for this purpose but is limited in some clinical settings because of inherently low signal-to-noise ratio. Since changes in fluid content also induce changes in thoracic capacitive and inductive properties, we tested whether a noninvasive CO measurement could be obtained through measurement of the relative phase shift of an injected current (i.e., bioreactance). We constructed a prototype device that applies a 75-kHz current and determines the relative phase shift (dPhi/dt) of the recorded transthoracic voltage. CO was related to the product of peak dPhi/dt, heart rate, and ventricular ejection time. The preclinical study was done in nine open-chest pigs put on right heart bypass so that CO could be varied at known values. This was followed by a feasibility study in 27 postoperative patients who had a Swan-Ganz catheter (SGC). The measurements of noninvasive CO measurement and cardiopulmonary bypass pump correlated to each other (r = 0.84) despite the large variation in CO and temperatures. Similarly, in patients, mean CO values were 5.18 and 5.17 l/min as measured by SGC and the noninvasive CO measurement system, respectively, and were highly correlated over the range of values studied (r = 0.90). Preclinical and clinical data demonstrate the feasibility of using blood flow-related phase shifts of transthoracic electric signals to perform noninvasive continuous CO monitoring.

Entities:  

Mesh:

Year:  2007        PMID: 17384132     DOI: 10.1152/ajpheart.00195.2007

Source DB:  PubMed          Journal:  Am J Physiol Heart Circ Physiol        ISSN: 0363-6135            Impact factor:   4.733


  68 in total

1.  The effect of head up tilting on bioreactance cardiac output and stroke volume readings using suprasternal transcutaneous Doppler as a control in healthy young adults.

Authors:  Jie Zhang; Lester A H Critchley; Daniel C W Lee; Kim S Khaw; Shara W Y Lee
Journal:  J Clin Monit Comput       Date:  2016-02-12       Impact factor: 2.502

2.  Application of bioreactance for cardiac output assessment during exercise in healthy individuals.

Authors:  Adrian Elliott; James H Hull; David Nunan; Djordje G Jakovljevic; David Brodie; Lesley Ansley
Journal:  Eur J Appl Physiol       Date:  2010-03-25       Impact factor: 3.078

3.  Impact of dexmedetomidine versus propofol on cardiac function of children undergoing laparoscopic surgery.

Authors:  Hongbin Gu; Jinfen Liu; Chi Wu
Journal:  Int J Clin Exp Med       Date:  2014-12-15

4.  Peak cardiac power measured noninvasively with a bioreactance technique is a predictor of adverse outcomes in patients with advanced heart failure.

Authors:  Hannah Rosenblum; Stephen Helmke; Paula Williams; Sergio Teruya; Margaret Jones; Daniel Burkhoff; Donna Mancini; Mathew S Maurer
Journal:  Congest Heart Fail       Date:  2010-10-19

Review 5.  The arterial Windkessel.

Authors:  Nico Westerhof; Jan-Willem Lankhaar; Berend E Westerhof
Journal:  Med Biol Eng Comput       Date:  2008-06-10       Impact factor: 2.602

6.  Suppression of cerebral hemodynamics is associated with reduced functional capacity in patients with heart failure.

Authors:  Tieh-Cheng Fu; Chao-Hung Wang; Chih-Chin Hsu; Wen-Jin Cherng; Shu-Chun Huang; Jong-Shyan Wang
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-01-28       Impact factor: 4.733

7.  Tracking changes in cardiac output: methodological considerations for the validation of monitoring devices.

Authors:  Pierre Squara; Maurizio Cecconi; Andrew Rhodes; Mervyn Singer; Jean-Daniel Chiche
Journal:  Intensive Care Med       Date:  2009-07-11       Impact factor: 17.440

8.  The passive leg raise test to predict fluid responsiveness in children--preliminary observations.

Authors:  Guo-ping Lu; Gangfeng Yan; Yang Chen; Zhu-jin Lu; Lin-en Zhang; Niranjan Kissoon
Journal:  Indian J Pediatr       Date:  2013-12-11       Impact factor: 1.967

9.  Lung water assessment: from gravimetry to wearables.

Authors:  Frederic Michard
Journal:  J Clin Monit Comput       Date:  2018-05-11       Impact factor: 2.502

10.  Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique.

Authors:  Nirav Y Raval; Pierre Squara; Michael Cleman; Kishore Yalamanchili; Michael Winklmaier; Daniel Burkhoff
Journal:  J Clin Monit Comput       Date:  2008-03-14       Impact factor: 2.502