Literature DB >> 17371722

Validation of V-SS-PARSE for single-shot flow measurement.

Jin Zuo1, Mark Bolding, Donald B Twieg.   

Abstract

As a variant of Single-Shot Parameter Assessment by Retrieval from Signal Encoding, Velocity Single-Shot Parameter Assessment by Retrieval from Signal Encoding, a single-shot imaging method, has been developed to realize fast and straightforward flow quantification by solving inverse problems. A robust signal model, including its local magnetization and its phase evolution during signaling (resulting in a more precise representation of the sampled signal) is described here. Magnitude, velocity, relaxation rate and frequency information can be retrieved without any extra reference image acquisitions, as demonstrated by phantom studies. In the presence of stationary background, retrieved magnitude maps and velocity maps show results comparable to those obtained by phase-contrast methods (r>.99, P=.005), even with brief single-shot 70-ms acquisition.

Mesh:

Year:  2006        PMID: 17371722      PMCID: PMC2034512          DOI: 10.1016/j.mri.2006.09.010

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  15 in total

1.  Undersampled projection reconstruction applied to MR angiography.

Authors:  D C Peters; F R Korosec; T M Grist; W F Block; J E Holden; K K Vigen; C A Mistretta
Journal:  Magn Reson Med       Date:  2000-01       Impact factor: 4.668

2.  Magnetic resonance real-time imaging for the evaluation of left ventricular function.

Authors:  E Nagel; U Schneider; S Schalla; T Ibrahim; B Schnackenburg; A Bornstedt; C Klein; H B Lehmkuhl; E Fleck
Journal:  J Cardiovasc Magn Reson       Date:  2000       Impact factor: 5.364

3.  Flow-gated phase-contrast MRI using radial acquisitions.

Authors:  Richard B Thompson; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2004-09       Impact factor: 4.668

Review 4.  Phase contrast cine magnetic resonance imaging.

Authors:  N J Pelc; R J Herfkens; A Shimakawa; D R Enzmann
Journal:  Magn Reson Q       Date:  1991-10

5.  Real-time interactive MRI on a conventional scanner.

Authors:  A B Kerr; J M Pauly; B S Hu; K C Li; C J Hardy; C H Meyer; A Macovski; D G Nishimura
Journal:  Magn Reson Med       Date:  1997-09       Impact factor: 4.668

Review 6.  Multishot rosette trajectories for spectrally selective MR imaging.

Authors:  D C Noll
Journal:  IEEE Trans Med Imaging       Date:  1997-08       Impact factor: 10.048

7.  Improvements in snap-shot nuclear magnetic resonance imaging.

Authors:  A M Howseman; M K Stehling; B Chapman; R Coxon; R Turner; R J Ordidge; M G Cawley; P Glover; P Mansfield; R E Coupland
Journal:  Br J Radiol       Date:  1988-09       Impact factor: 3.039

8.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

9.  A flow velocity zeugmatographic interlace for NMR imaging in humans.

Authors:  P R Moran
Journal:  Magn Reson Imaging       Date:  1982       Impact factor: 2.546

10.  A novel k-space trajectory measurement technique.

Authors:  Y Zhang; H P Hetherington; E M Stokely; G F Mason; D B Twieg
Journal:  Magn Reson Med       Date:  1998-06       Impact factor: 4.668

View more
  3 in total

1.  Snapshot MR technique to measure OEF using rapid frequency mapping.

Authors:  Rajiv G Menon; Edward G Walsh; Donald B Twieg; Charles G Cantrell; Parmede Vakil; Sumeeth V Jonathan; Hunt H Batjer; Timothy J Carroll
Journal:  J Cereb Blood Flow Metab       Date:  2014-04-23       Impact factor: 6.200

2.  Basic properties of SS-PARSE parameter estimates.

Authors:  Donald B Twieg; Stanley J Reeves
Journal:  IEEE Trans Med Imaging       Date:  2010-03-18       Impact factor: 10.048

Review 3.  [Update: clinical imaging of cartilage-part 1 : Technical aspects].

Authors:  C Glaser; A Heuck; A Horng
Journal:  Radiologe       Date:  2019-08       Impact factor: 0.635

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.