Literature DB >> 9339436

Real-time interactive MRI on a conventional scanner.

A B Kerr1, J M Pauly, B S Hu, K C Li, C J Hardy, C H Meyer, A Macovski, D G Nishimura.   

Abstract

A real-time interactive MRI system capable of localizing coronary arteries and imaging arrhythmic hearts in real-time is described. Non-2DFT acquisition strategies such as spiral-interleaf, spiral-ring, and circular echo-planar imaging provide short scan times on a conventional scanner. Real-time gridding reconstruction at 8-20 images/s is achieved by distributing the reconstruction on general-purpose UNIX workstations. An X-windows application provides interactive control. A six-interleaf spiral sequence is used for cardiac imaging and can acquire six images/s. A sliding window reconstruction achieves display rates of 16-20 images/s. This allows cardiac images to be acquired in real-time, with minimal motion and flow artifacts, and without breath holding or cardiac gating. Abdominal images are acquired at over 2.5 images/s with spiral-ring or circular echo-planar sequences. Reconstruction rates are 8-10 images/s. Rapid localization in the abdomen is demonstrated with the spiral-ring acquisition, whereas peristaltic motion in the small bowel is well visualized using the circular echo-planar sequence.

Entities:  

Mesh:

Year:  1997        PMID: 9339436     DOI: 10.1002/mrm.1910380303

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  26 in total

1.  Undersampled projection reconstruction for active catheter imaging with adaptable temporal resolution and catheter-only views.

Authors:  Dana C Peters; Robert J Lederman; Alexander J Dick; Venkatesh K Raman; Michael A Guttman; J Andrew Derbyshire; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

2.  Real-time volume rendered MRI for interventional guidance.

Authors:  Michael A Guttman; Robert J Lederman; Jonathan M Sorger; Elliot R McVeigh
Journal:  J Cardiovasc Magn Reson       Date:  2002       Impact factor: 5.364

3.  Real-time accelerated interactive MRI with adaptive TSENSE and UNFOLD.

Authors:  Michael A Guttman; Peter Kellman; Alexander J Dick; Robert J Lederman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-08       Impact factor: 4.668

4.  Large field-of-view real-time MRI with a 32-channel system.

Authors:  Christopher J Hardy; Robert D Darrow; Manojkumar Saranathan; Randy O Giaquinto; Yudong Zhu; Charles L Dumoulin; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2004-10       Impact factor: 4.668

5.  Improvements in spiral MR imaging.

Authors:  P Börnert; H Schomberg; B Aldefeld; J Groen
Journal:  MAGMA       Date:  1999-10       Impact factor: 2.310

Review 6.  The future of real-time cardiac magnetic resonance imaging.

Authors:  Krishna S Nayak; Bob S Hu
Journal:  Curr Cardiol Rep       Date:  2005-01       Impact factor: 2.931

7.  Real-time color-flow CMR in adults with congenital heart disease.

Authors:  Erasmo de la Pena; Patricia K Nguyen; Krishna S Nayak; Phillip C Yang; David N Rosenthal; Bob S Hu; John M Pauly; Michael V McConnell
Journal:  J Cardiovasc Magn Reson       Date:  2006       Impact factor: 5.364

8.  Validation of V-SS-PARSE for single-shot flow measurement.

Authors:  Jin Zuo; Mark Bolding; Donald B Twieg
Journal:  Magn Reson Imaging       Date:  2006-11-13       Impact factor: 2.546

9.  A circular echo planar sequence for fast volumetric fMRI.

Authors:  Christoph Rettenmeier; Danilo Maziero; Yongxian Qian; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2018-10-01       Impact factor: 4.668

10.  3-T navigator parallel-imaging coronary MR angiography: targeted-volume versus whole-heart acquisition.

Authors:  Shixin Chang; Matthew D Cham; Shuguang Hu; Yi Wang
Journal:  AJR Am J Roentgenol       Date:  2008-07       Impact factor: 3.959

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.