Literature DB >> 17364179

Radiolucent lines below the tibial component of a total knee replacement (TKR)--a comparison between single-and two-stage cementation techniques.

Abhijit Ranjan Guha1, Ujjwal Kanti Debnath, Niall McKenzie Graham.   

Abstract

Early non-progressive horizontal radiolucent lines (RLLs) (<2 mm) under the tibial component following cemented total knee replacement (TKR) are considered to result from poor cement injection into cancellous bone. These RLLs may facilitate the entry of joint fluid and wear debris into the interface, which may proceed to ballooning osteolysis. There is currently no consensus on the preferred cementing technique (single- versus two-stage cementation) in TKR. We have prospectively analysed postoperative radiographs in 50 consecutive TKRs to compare the RLLs following single- (25 TKRs) and two-stage (25 TKRs) cementation techniques. Of the TKR radiographs studied, 26 (52%) had RLLs; nine (36%) of these were single-stage TKRs, and 17 (68%) were two-stage TKRs. This study demonstrates that single-stage cementing may be superior to the two-stage technique in terms of avoiding RLLs in immediate postoperative TKRs.

Entities:  

Mesh:

Year:  2007        PMID: 17364179      PMCID: PMC2532273          DOI: 10.1007/s00264-007-0345-6

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  13 in total

1.  Suction technique to improve cement penetration under the tibial component in total knee arthroplasty.

Authors:  Kate Stannage; David Shakespeare; Max Bulsara
Journal:  Knee       Date:  2003-03       Impact factor: 2.199

2.  Reproducible assessment of radiolucent lines in total knee arthroplasty.

Authors:  Christian Michael Bach; Rainer Biedermann; Georg Goebel; Ekard Mayer; Franz Rachbauer
Journal:  Clin Orthop Relat Res       Date:  2005-05       Impact factor: 4.176

3.  The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system.

Authors:  F C Ewald
Journal:  Clin Orthop Relat Res       Date:  1989-11       Impact factor: 4.176

4.  A longitudinal study of the radiolucent line at the bone-cement interface following total joint-replacement procedures.

Authors:  F W Reckling; M A Asher; W L Dillon
Journal:  J Bone Joint Surg Am       Date:  1977-04       Impact factor: 5.284

5.  Control of cement penetration in total knee arthroplasty.

Authors:  P S Walker; M Soudry; F C Ewald; H McVickar
Journal:  Clin Orthop Relat Res       Date:  1984-05       Impact factor: 4.176

6.  Strength of the cement-bone interface.

Authors:  W R Krause; W Krug; J Miller
Journal:  Clin Orthop Relat Res       Date:  1982-03       Impact factor: 4.176

7.  Radiologic evaluation of knee arthroplasty.

Authors:  R Schneider; R W Hood; C S Ranawat
Journal:  Orthop Clin North Am       Date:  1982-01       Impact factor: 2.472

8.  The radiolucent zone in arthroplasty of the knee.

Authors:  A Ahlberg; B Lindén
Journal:  Acta Orthop Scand       Date:  1977

9.  Long-term results after total condylar knee arthroplasty. Significance of radiolucent lines.

Authors:  M L Ecker; P A Lotke; R E Windsor; J P Cella
Journal:  Clin Orthop Relat Res       Date:  1987-03       Impact factor: 4.176

Review 10.  The science of bone cement: a historical review.

Authors:  Frank R DiMaio
Journal:  Orthopedics       Date:  2002-12       Impact factor: 1.390

View more
  14 in total

1.  Pulsed lavage improves fixation strength of cemented tibial components.

Authors:  Ulf J Schlegel; Jan Siewe; Karl S Delank; Peer Eysel; Klaus Püschel; Michael M Morlock; Anne Gebert de Uhlenbrock
Journal:  Int Orthop       Date:  2010-10-16       Impact factor: 3.075

2.  Pulsed lavage reduces the incidence of radiolucent lines under the tibial tray of Oxford unicompartmental knee arthroplasty: pulsed lavage versus syringe lavage.

Authors:  Michael Clarius; Christian Hauck; Joern B Seeger; Andrew James; David W Murray; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-02-14       Impact factor: 3.075

3.  Does negative pressure intrusion cementing technique improve the cement penetration under the tibial component? A comparative retrospective study.

Authors:  Giorgio Cacciola; Federico De Meo; Pietro Cavaliere
Journal:  J Orthop       Date:  2019-11-27

4.  Increased initial cement-bone interlock correlates with reduced total knee arthroplasty micro-motion following in vivo service.

Authors:  Mark A Miller; Matthew J Terbush; Jacklyn R Goodheart; Timothy H Izant; Kenneth A Mann
Journal:  J Biomech       Date:  2014-04-16       Impact factor: 2.712

5.  Long-term follow-up of a non-randomised prospective cohort of one hundred and ninety two total knee arthroplasties using the NexGen implant.

Authors:  Alfredo Schiavone Panni; Franceso Falez; Rocco D'Apolito; Katia Corona; Carlo Perisano; Michele Vasso
Journal:  Int Orthop       Date:  2017-03-22       Impact factor: 3.075

6.  The effect of multiple drilling on a sclerotic proximal tibia during total knee arthroplasty.

Authors:  Ji Hyun Ahn; Seung Hyo Jeong; Sung Hyun Lee
Journal:  Int Orthop       Date:  2014-10-11       Impact factor: 3.075

Review 7.  Highly cross-linked polyethylene in primary total knee arthroplasty is associated with a lower rate of revision for aseptic loosening: a meta-analysis of 962,467 cases.

Authors:  Ioannis Gkiatas; Theofilos Karasavvidis; Abhinav K Sharma; William Xiang; Michael-Alexander Malahias; Brian P Chalmers; Peter K Sculco
Journal:  Arch Orthop Trauma Surg       Date:  2021-04-13       Impact factor: 3.067

8.  Progressive loss of implant fixation in a preclinical rat model of cemented knee arthroplasty.

Authors:  Kenneth A Mann; Mark A Miller; Jeffrey K Rossow; Megan E Tatusko; Jason A Horton; Timothy A Damron; Megan E Oest
Journal:  J Orthop Res       Date:  2021-02-24       Impact factor: 3.494

9.  First clinical study of a novel complete metal-free ceramic total knee replacement system.

Authors:  E Meier; K Gelse; K Trieb; M Pachowsky; F F Hennig; A Mauerer
Journal:  J Orthop Surg Res       Date:  2016-02-08       Impact factor: 2.359

10.  Metal block augmentation for bone defects of the medial tibia during primary total knee arthroplasty.

Authors:  Sachiyuki Tsukada; Motohiro Wakui; Munenori Matsueda
Journal:  J Orthop Surg Res       Date:  2013-10-20       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.