Literature DB >> 16092337

A comparison of a similarity-based and a feature-based 2-D-3-D registration method for neurointerventional use.

Robert A McLaughlin1, John Hipwell, David J Hawkes, J Alison Noble, James V Byrne, Tim C Cox.   

Abstract

Two-dimensional (2-D)-to-three-dimensional (3-D) registration can improve visualization which may aid minimally invasive neurointerventions. Using clinical and phantom studies, two state-of-the-art approaches to rigid registration are compared quantitatively: an intensity-based algorithm using the gradient difference similarity measure; and an iterative closest point (ICP)-based algorithm. The gradient difference approach was found to be more accurate, with an average registration accuracy of 1.7 mm for clinical data, compared to the ICP-based algorithm with an average accuracy of 2.8 mm. In phantom studies, the ICP-based algorithm proved more reliable, but with more complicated clinical data, the gradient difference algorithm was more robust. Average computation time for the ICP-based algorithm was 20 s per registration, compared with 14 min and 50 s for the gradient difference algorithm.

Entities:  

Mesh:

Year:  2005        PMID: 16092337     DOI: 10.1109/TMI.2005.852067

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  13 in total

1.  Rigid registration of medical images using 1D and 2D binary projections.

Authors:  Panayiotis Kotsas; Tony Dodd
Journal:  J Digit Imaging       Date:  2011-10       Impact factor: 4.056

2.  3D/2D model-to-image registration applied to TIPS surgery.

Authors:  Julien Jomier; Elizabeth Bullitt; Mark Van Horn; Chetna Pathak; Stephen R Aylward
Journal:  Med Image Comput Comput Assist Interv       Date:  2006

3.  Automatic registration of CT volumes and dual-energy digital radiography for detection of cardiac and lung diseases.

Authors:  Baowei Fei; Xiang Chen; Hesheng Wang; John M Sabol; Elena DuPont; Robert C Gilkeson
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

4.  Automatic 3D-to-2D registration for CT and dual-energy digital radiography for calcification detection.

Authors:  Xiang Chen; Robert C Gilkeson; Baowei Fei
Journal:  Med Phys       Date:  2007-12       Impact factor: 4.071

5.  Two-stage point-based registration method between ultrasound and CT imaging of the liver based on ICP and unscented Kalman filter: a phantom study.

Authors:  F Nazem; A Ahmadian; N Dadashi Seraj; M Giti
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-06-20       Impact factor: 2.924

6.  Validation for 2D/3D registration. II: The comparison of intensity- and gradient-based merit functions using a new gold standard data set.

Authors:  Christelle Gendrin; Primoz Markelj; Supriyanto Ardjo Pawiro; Jakob Spoerk; Christoph Bloch; Christoph Weber; Michael Figl; Helmar Bergmann; Wolfgang Birkfellner; Bostjan Likar; Franjo Pernus
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

7.  3D-2D image registration for target localization in spine surgery: investigation of similarity metrics providing robustness to content mismatch.

Authors:  T De Silva; A Uneri; M D Ketcha; S Reaungamornrat; G Kleinszig; S Vogt; N Aygun; S-F Lo; J-P Wolinsky; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2016-03-18       Impact factor: 3.609

8.  Automatic localization of vertebral levels in x-ray fluoroscopy using 3D-2D registration: a tool to reduce wrong-site surgery.

Authors:  Y Otake; S Schafer; J W Stayman; W Zbijewski; G Kleinszig; R Graumann; A J Khanna; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2012-08-03       Impact factor: 3.609

9.  Robust 3D-2D image registration: application to spine interventions and vertebral labeling in the presence of anatomical deformation.

Authors:  Yoshito Otake; Adam S Wang; J Webster Stayman; Ali Uneri; Gerhard Kleinszig; Sebastian Vogt; A Jay Khanna; Ziya L Gokaslan; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2013-11-18       Impact factor: 3.609

10.  Motion correction of in vivo three-dimensional optical coherence tomography of human skin using a fiducial marker.

Authors:  Yih Miin Liew; Robert A McLaughlin; Fiona M Wood; David D Sampson
Journal:  Biomed Opt Express       Date:  2012-06-29       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.