Literature DB >> 19048346

Toward quantitative small animal pinhole SPECT: assessment of quantitation accuracy prior to image compensations.

Chia-Lin Chen1, Yuchuan Wang, Jason J S Lee, Benjamin M W Tsui.   

Abstract

PURPOSE: We assessed the quantitation accuracy of small animal pinhole single photon emission computed tomography (SPECT) under the current preclinical settings, where image compensations are not routinely applied. PROCEDURES: The effects of several common image-degrading factors and imaging parameters on quantitation accuracy were evaluated using Monte-Carlo simulation methods. Typical preclinical imaging configurations were modeled, and quantitative analyses were performed based on image reconstructions without compensating for attenuation, scatter, and limited system resolution.
RESULTS: Using mouse-sized phantom studies as examples, attenuation effects alone degraded quantitation accuracy by up to -18% (Tc-99m or In-111) or -41% (I-125). The inclusion of scatter effects changed the above numbers to -12% (Tc-99m or In-111) and -21% (I-125), respectively, indicating the significance of scatter in quantitative I-125 imaging. Region-of-interest (ROI) definitions have greater impacts on regional quantitation accuracy for small sphere sources as compared to attenuation and scatter effects. For the same ROI, SPECT acquisitions using pinhole apertures of different sizes could significantly affect the outcome, whereas the use of different radii-of-rotation yielded negligible differences in quantitation accuracy for the imaging configurations simulated.
CONCLUSIONS: We have systematically quantified the influence of several factors affecting the quantitation accuracy of small animal pinhole SPECT. In order to consistently achieve accurate quantitation within 5% of the truth, comprehensive image compensation methods are needed.

Entities:  

Mesh:

Year:  2008        PMID: 19048346      PMCID: PMC3085830          DOI: 10.1007/s11307-008-0181-0

Source DB:  PubMed          Journal:  Mol Imaging Biol        ISSN: 1536-1632            Impact factor:   3.488


  15 in total

Review 1.  Molecular imaging.

Authors:  R Weissleder; U Mahmood
Journal:  Radiology       Date:  2001-05       Impact factor: 11.105

2.  Evaluation of penetration and scattering components in conventional pinhole SPECT: phantom studies using Monte Carlo simulation.

Authors:  Hossain M Deloar; Hiroshi Watabe; Toshiyuki Aoi; Hidehiro Iida
Journal:  Phys Med Biol       Date:  2003-04-21       Impact factor: 3.609

Review 3.  Small animal SPECT and its place in the matrix of molecular imaging technologies.

Authors:  Steven R Meikle; Peter Kench; Michael Kassiou; Richard B Banati
Journal:  Phys Med Biol       Date:  2005-10-24       Impact factor: 3.609

4.  GATE: a simulation toolkit for PET and SPECT.

Authors:  S Jan; G Santin; D Strul; S Staelens; K Assié; D Autret; S Avner; R Barbier; M Bardiès; P M Bloomfield; D Brasse; V Breton; P Bruyndonckx; I Buvat; A F Chatziioannou; Y Choi; Y H Chung; C Comtat; D Donnarieix; L Ferrer; S J Glick; C J Groiselle; D Guez; P F Honore; S Kerhoas-Cavata; A S Kirov; V Kohli; M Koole; M Krieguer; D J van der Laan; F Lamare; G Largeron; C Lartizien; D Lazaro; M C Maas; L Maigne; F Mayet; F Melot; C Merheb; E Pennacchio; J Perez; U Pietrzyk; F R Rannou; M Rey; D R Schaart; C R Schmidtlein; L Simon; T Y Song; J M Vieira; D Visvikis; R Van de Walle; E Wieërs; C Morel
Journal:  Phys Med Biol       Date:  2004-10-07       Impact factor: 3.609

5.  The importance and implementation of accurate 3D compensation methods for quantitative SPECT.

Authors:  B M Tsui; E C Frey; X Zhao; D S Lalush; R E Johnston; W H McCartney
Journal:  Phys Med Biol       Date:  1994-03       Impact factor: 3.609

6.  Integration of SimSET photon history generator in GATE for efficient Monte Carlo simulations of pinhole SPECT.

Authors:  Chia-Lin Chen; Yuchuan Wang; Jason J S Lee; Benjamin M W Tsui
Journal:  Med Phys       Date:  2008-07       Impact factor: 4.071

Review 7.  Quantitative single-photon emission computed tomography: basics and clinical considerations.

Authors:  B M Tsui; X Zhao; E C Frey; W H McCartney
Journal:  Semin Nucl Med       Date:  1994-01       Impact factor: 4.446

8.  Quantification of dopamine transporters in the mouse brain using ultra-high resolution single-photon emission tomography.

Authors:  Paul D Acton; Seok-Rye Choi; Karl Plössl; Hank F Kung
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-03-07       Impact factor: 9.236

9.  Development of a 4-D digital mouse phantom for molecular imaging research.

Authors:  William P Segars; Benjamin M W Tsui; Eric C Frey; G Allan Johnson; Stuart S Berr
Journal:  Mol Imaging Biol       Date:  2004 May-Jun       Impact factor: 3.488

10.  Quantitative analysis of acute myocardial infarct in rat hearts with ischemia-reperfusion using a high-resolution stationary SPECT system.

Authors:  Zhonglin Liu; George A Kastis; Gail D Stevenson; Harrison H Barrett; Lars R Furenlid; Matthew A Kupinski; Dennis D Patton; Donald W Wilson
Journal:  J Nucl Med       Date:  2002-07       Impact factor: 10.057

View more
  9 in total

1.  Filled and glycosylated carbon nanotubes for in vivo radioemitter localization and imaging.

Authors:  Sung You Hong; Gerard Tobias; Khuloud T Al-Jamal; Belén Ballesteros; Hanene Ali-Boucetta; Sergio Lozano-Perez; Peter D Nellist; Robert B Sim; Ciara Finucane; Stephen J Mather; Malcolm L H Green; Kostas Kostarelos; Benjamin G Davis
Journal:  Nat Mater       Date:  2010-05-16       Impact factor: 43.841

2.  Comparative analysis of peptide p5 and serum amyloid P component for imaging AA amyloid in mice using dual-isotope SPECT.

Authors:  Jonathan S Wall; Tina Richey; Angela Williams; Alan Stuckey; Dustin Osborne; Emily Martin; Stephen J Kennel
Journal:  Mol Imaging Biol       Date:  2012-08       Impact factor: 3.488

3.  Characterization of a high-purity germanium detector for small-animal SPECT.

Authors:  Lindsay C Johnson; Desmond L Campbell; Ethan L Hull; Todd E Peterson
Journal:  Phys Med Biol       Date:  2011-08-18       Impact factor: 3.609

4.  Advances in preclinical SPECT instrumentation.

Authors:  Todd E Peterson; Sepideh Shokouhi
Journal:  J Nucl Med       Date:  2012-05-14       Impact factor: 10.057

5.  Molecular SPECT Imaging: An Overview.

Authors:  Magdy M Khalil; Jordi L Tremoleda; Tamer B Bayomy; Willy Gsell
Journal:  Int J Mol Imaging       Date:  2011-04-05

6.  Quantitative Accuracy of Low-Count SPECT Imaging in Phantom and In Vivo Mouse Studies.

Authors:  Ciara M Finucane; Iain Murray; Jane K Sosabowski; Julie M Foster; Stephen J Mather
Journal:  Int J Mol Imaging       Date:  2011-03-16

Review 7.  Molecular Imaging of Pancreatic Cancer with Antibodies.

Authors:  Christopher G England; Reinier Hernandez; Savo Bou Zein Eddine; Weibo Cai
Journal:  Mol Pharm       Date:  2015-12-10       Impact factor: 4.939

8.  Pre-clinical quantitative imaging and mouse-specific dosimetry for 111In-labelled radiotracers.

Authors:  Ana M Denis-Bacelar; Sarah E Cronin; Chiara Da Pieve; Rowena L Paul; Sue A Eccles; Terence J Spinks; Carol Box; Adrian Hall; Jane K Sosabowski; Gabriela Kramer-Marek; Glenn D Flux
Journal:  EJNMMI Res       Date:  2016-11-25       Impact factor: 3.138

Review 9.  The role of preclinical SPECT in oncological and neurological research in combination with either CT or MRI.

Authors:  Monique R Bernsen; Pieter E B Vaissier; Roel Van Holen; Jan Booij; Freek J Beekman; Marion de Jong
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-05       Impact factor: 9.236

  9 in total