Literature DB >> 18227963

Intra-articular compressive stress of the elbow joint in extension: an experimental study using Fuji films.

C Chantelot1, G Wavreille, C Dos Remedios, B Landejerit, C Fontaine, H Hildebrand.   

Abstract

The use of Fuji films is simple but their manipulation and result interpretation seem to be difficult in the framework of medical research. The reliability and reproducibility of Fuji films have been proved by many previous studies. This study was undertaken to know precisely the articular zones of the elbow and to determine the compressive stress these areas undergo during different activities, in order to assess the importance of different articular contact areas. These data indicate the need for better-adapted elbow prosthesis and can be eventually used to design more durable prosthesis for the elbow. The compressive stress on the radial head was less than 25% in extension. The stress on the radial head varied from the neutral position (23% of the stress), to full pronation (11% of the stress) and to full supination (6% of the stress). The Humero-ulnar compartment had the maximum impact. Coronoid process seemed to be a fundamental element of the elbow joint in extension (60% of total compressive stress). The Medial humero-ulnar compartment was less stressed than the lateral compartment. The radial head does not seem to play a major role in the stability of the elbow in extension if the ulnar collateral ligament exists. The ulnar collateral ligament is essential to the elbow joint stability. The lifespan of a non-constrained prosthesis would depend on the existence of the couple: radial head/ulnar collateral ligament; the absence of radial head could compromise the humero-ulnar stability. This work paved the way for the designing of new non-constrained elbow prosthesis with the reconstruction of the radial head.

Mesh:

Substances:

Year:  2008        PMID: 18227963     DOI: 10.1007/s00276-007-0297-y

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  31 in total

1.  Fuji film and ultrasound measurement of total knee arthroplasty contact areas.

Authors:  R Zdero; P V Fenton; J Rudan; J T Bryant
Journal:  J Arthroplasty       Date:  2001-04       Impact factor: 4.757

2.  Biomechanical study of ligaments around the elbow joint.

Authors:  W D Regan; S L Korinek; B F Morrey; K N An
Journal:  Clin Orthop Relat Res       Date:  1991-10       Impact factor: 4.176

3.  A stereophotogrammetric method for determining in situ contact areas in diarthrodial joints, and a comparison with other methods.

Authors:  G A Ateshian; S D Kwak; L J Soslowsky; V C Mow
Journal:  J Biomech       Date:  1994-01       Impact factor: 2.712

4.  The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement.

Authors:  D L Bartel; V L Bicknell; T M Wright
Journal:  J Bone Joint Surg Am       Date:  1986-09       Impact factor: 5.284

5.  Stress distribution in the trochlear notch. A model of bicentric load transmission through joints.

Authors:  F Eckstein; F Löhe; M Müller-Gerbl; M Steinlechner; R Putz
Journal:  J Bone Joint Surg Br       Date:  1994-07

6.  In-vitro measurement of static pressure distribution in synovial joints--Part I: Tibial surface of the knee.

Authors:  A M Ahmed; D L Burke
Journal:  J Biomech Eng       Date:  1983-08       Impact factor: 2.097

7.  A new technique for measuring contact areas in human joints--the '3S technique'.

Authors:  J Q Yao; B B Seedhom
Journal:  Proc Inst Mech Eng H       Date:  1991       Impact factor: 1.617

8.  [Effect of anterior and posterior capsule release on elbow joint stability: an experimental study].

Authors:  C Dos Remedios; C Chantelot; H Migaud; D Le Nen; C Fontaine; B Landjerit
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2003-12

9.  Sterilization of Fuji pressure-sensitive film.

Authors:  A B Liggins; W R Hardie; J B Finlay
Journal:  Med Eng Phys       Date:  1994-11       Impact factor: 2.242

10.  Morphometric parameters of the radial neck: an anatomical study.

Authors:  T C Koslowsky; F Beyer; I Germund; K Mader; M Jergas; J Koebke
Journal:  Surg Radiol Anat       Date:  2007-05-10       Impact factor: 1.354

View more
  3 in total

1.  Experimental determination of the elbow's center of rotation using the VICON™ optoelectronic motion capture system.

Authors:  Elvire Guerre; Pascale Laronde; Jérôme Cussonneau; Christian Fontaine; Guillaume Wavreille
Journal:  Surg Radiol Anat       Date:  2015-11-20       Impact factor: 1.246

2.  Do the radial head prosthesis components fit with the anatomical structures of the proximal radioulnar joint?

Authors:  Kilian Wegmann; Moritz K Hain; Christian Ries; Wolfram F Neiss; Lars P Müller; Klaus J Burkhart
Journal:  Surg Radiol Anat       Date:  2014-12-28       Impact factor: 1.246

3.  Evaluation of the contact surface between vertebral endplate and 3D printed patient-specific cage vs commercial cage.

Authors:  Renan Jose Rodrigues Fernandes; Aaron Gee; Andrew James Kanawati; Fawaz Siddiqi; Parham Rasoulinejad; Radovan Zdero; Christopher Stewart Bailey
Journal:  Sci Rep       Date:  2022-07-22       Impact factor: 4.996

  3 in total