Literature DB >> 12955369

Enhancing accuracy of magnetic resonance image fusion by defining a volume of interest.

B M Hoelper1, F Soldner, R Lachner, R Behr.   

Abstract

We compared the registration accuracy for corresponding anatomical landmarks in two MR images after fusing the complete volume (CV) and a defined volume of interest (VOI) of both MRI data sets. We carried out contrast-enhanced T1-weighted gradient-echo and T2-weighted fast spin-echo MRI (matrix 256 x 256) in 39 cases. The CV and a defined VOI data set were each fused using prototype software. We measured and analysed the distance between 25 anatomical landmarks in predefined areas identified at levels L(1)-L(5) corresponding to defined axial sections. Fusion technique, landmark areas and level of fusion were further processed using a feed-forward neural network to calculate the difference which can be expected based on the measurements. We identified 975 landmarks for both T1- and T2-weighted images and found a significant difference in registration accuracy ( P<0.01) for all landmarks between CV (1.6+/-1.2 mm) and VOI (0.7+/-1.0 mm). From cranial (L(1)) to caudal (L(5)), mean deviations were: L(1) CV 1.5 mm, VOI 0.5 mm; L(2) CV 1.8 mm, VOI 0.4 mm; L(3) CV 1.7 mm, VOI 0.4 mm; L(4) CV 1.6 mm, VOI 0.6 mm; and L(5) CV 1.6 mm, VOI 1.6 mm. Neural network analysis predicted a higher accuracy for VOI (0.05-0.15 mm) than for CV fusion (0.9-1.6 mm). Deviations due to magnetic susceptibility changes between air and tissue seen on gradient-echo images can decrease fusion accuracy. Our VOI fusion technique improves image fusion accuracy to <0.5 mm by excluding areas with marked susceptibility changes.

Mesh:

Year:  2003        PMID: 12955369     DOI: 10.1007/s00234-003-1071-4

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  20 in total

1.  The application of image fusion in stereotactic brachytherapy of brain tumours.

Authors:  J Julow; T Major; M Emri; I Valálik; S Sági; L Mangel; G Németh; L Trón; G Várallyay; D Solymosi; J Hável; T Kiss
Journal:  Acta Neurochir (Wien)       Date:  2000       Impact factor: 2.216

2.  A versatile functional-anatomic image fusion method for volume data sets.

Authors:  M E Noz; G Q Maguire; M P Zeleznik; E L Kramer; F Mahmoud; J Crafoord
Journal:  J Med Syst       Date:  2001-10       Impact factor: 4.460

3.  Demonstration of accuracy and clinical versatility of mutual information for automatic multimodality image fusion using affine and thin-plate spline warped geometric deformations.

Authors:  C R Meyer; J L Boes; B Kim; P H Bland; K R Zasadny; P V Kison; K Koral; K A Frey; R L Wahl
Journal:  Med Image Anal       Date:  1997-04       Impact factor: 8.545

4.  Automated 3-D registration of MR and CT images of the head.

Authors:  C Studholme; D L Hill; D J Hawkes
Journal:  Med Image Anal       Date:  1996-06       Impact factor: 8.545

5.  Multi-modal volume registration by maximization of mutual information.

Authors:  W M Wells; P Viola; H Atsumi; S Nakajima; R Kikinis
Journal:  Med Image Anal       Date:  1996-03       Impact factor: 8.545

6.  Anatomic localization and quantitative analysis of gradient refocused echo-planar fMRI susceptibility artifacts.

Authors:  J G Ojemann; E Akbudak; A Z Snyder; R C McKinstry; M E Raichle; T E Conturo
Journal:  Neuroimage       Date:  1997-10       Impact factor: 6.556

7.  Registration error quantification of a surface-based multimodality image fusion system.

Authors:  P F Hemler; S Napel; T S Sumanaweera; R Pichumani; P A van den Elsen; D Martin; J Drace; J R Adler; I Perkash
Journal:  Med Phys       Date:  1995-07       Impact factor: 4.071

8.  Magnetic susceptibility artifacts on high-resolution MR of the temporal bone.

Authors:  M C Oehler; P Schmalbrock; D Chakeres; S Kurucay
Journal:  AJNR Am J Neuroradiol       Date:  1995-05       Impact factor: 3.825

9.  Data fusion in medical imaging: merging multimodal and multipatient images, identification of structures and 3D display aspects.

Authors:  C Barillot; D Lemoine; L Le Briquer; F Lachmann; B Gibaud
Journal:  Eur J Radiol       Date:  1993-06       Impact factor: 3.528

10.  Multimodal cranial neuronavigation: direct integration of functional magnetic resonance imaging and positron emission tomography data: technical note.

Authors:  V Braun; S Dempf; R Tomczak; A Wunderlich; R Weller; H P Richter
Journal:  Neurosurgery       Date:  2001-05       Impact factor: 4.654

View more
  1 in total

1.  A technique for achieving submillimeter accuracy of volume-staged stereotactic radiosurgery.

Authors:  Lijun Ma; Shannon Fogh; Nalin Gupta; Andrew Hwang; Dilini Pinnaduwage; Jean Nakamura; Igor Barani; Michael McDermott; Penny K Sneed; David A Larson; Arjun Sahgal
Journal:  J Radiosurg SBRT       Date:  2012
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.