Literature DB >> 18727039

Improved calibration technique for in vivo proton MRS thermometry for brain temperature measurement.

M Zhu1, A Bashir, J J Ackerman, D A Yablonskiy.   

Abstract

The most common MR-based approach to noninvasively measure brain temperature relies on the linear relationship between the (1)H MR resonance frequency of tissue water and the tissue's temperature. Herein we provide the most accurate in vivo assessment existing thus far of such a relationship. It was derived by acquiring in vivo MR spectra from a rat brain using a high field (11.74 Tesla [T]) MRI scanner and a single-voxel MR spectroscopy technique based on a LASER pulse sequence. Data were analyzed using three different methods to estimate the (1)H resonance frequencies of water and the metabolites NAA, Cho, and Cr, which are used as temperature-independent internal (frequency) references. Standard modeling of frequency-domain data as composed of resonances characterized by Lorentzian line shapes gave the tightest resonance-frequency versus temperature correlation. An analysis of the uncertainty in temperature estimation has shown that the major limiting factor is an error in estimating the metabolite frequency. For example, for a metabolite resonance linewidth of 8 Hz, signal sampling rate of 2 Hz and SNR of 5, an accuracy of approximately 0.5 degrees C can be achieved at a magnetic field of 3T. For comparison, in the current study conducted at 11.74T, the temperature estimation error was approximately 0.1 degrees C.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18727039      PMCID: PMC2913520          DOI: 10.1002/mrm.21699

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  25 in total

1.  Coupling between changes in human brain temperature and oxidative metabolism during prolonged visual stimulation.

Authors:  D A Yablonskiy; J J Ackerman; M E Raichle
Journal:  Proc Natl Acad Sci U S A       Date:  2000-06-20       Impact factor: 11.205

2.  TmDOTA-: a sensitive probe for MR thermometry in vivo.

Authors:  C S Zuo; A Mahmood; A D Sherry
Journal:  J Magn Reson       Date:  2001-07       Impact factor: 2.229

3.  The return of the frequency sweep: designing adiabatic pulses for contemporary NMR.

Authors:  M Garwood; L DelaBarre
Journal:  J Magn Reson       Date:  2001-12       Impact factor: 2.229

4.  Inhomogeneity correction for in vivo spectroscopy by high-resolution water referencing.

Authors:  P Webb; D Spielman; A Macovski
Journal:  Magn Reson Med       Date:  1992-01       Impact factor: 4.668

5.  A 1H-NMR method for determining temperature in cell culture perfusion systems.

Authors:  N W Lutz; A C Kuesel; W E Hull
Journal:  Magn Reson Med       Date:  1993-01       Impact factor: 4.668

6.  Temperature distribution measurements in two-dimensional NMR imaging.

Authors:  D L Parker; V Smith; P Sheldon; L E Crooks; L Fussell
Journal:  Med Phys       Date:  1983 May-Jun       Impact factor: 4.071

7.  Non-invasive magnetic resonance thermometry using thulium-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetate (TmDOTA(-)).

Authors:  S K Hekmatyar; H Poptani; A Babsky; D B Leeper; N Bansal
Journal:  Int J Hyperthermia       Date:  2002 May-Jun       Impact factor: 3.914

8.  Assessment of human brain temperature by 1H MRS during visual stimulation and hypercapnia.

Authors:  Risto A Kauppinen; Rishma Vidyasagar; Charmaine Childs; George M Balanos; Yrjo Hiltunen
Journal:  NMR Biomed       Date:  2008-05       Impact factor: 4.044

9.  N-acetyl-L-aspartate and acetate 1H NMR signal overlapping under mild acidic pH conditions.

Authors:  M Martin; J Labouesse; P Canioni; M Merle
Journal:  Magn Reson Med       Date:  1993-05       Impact factor: 4.668

10.  Java-based graphical user interface for the MRUI quantitation package.

Authors:  A Naressi; C Couturier; J M Devos; M Janssen; C Mangeat; R de Beer; D Graveron-Demilly
Journal:  MAGMA       Date:  2001-05       Impact factor: 2.533

View more
  16 in total

1.  Compatibility of temporary pacemaker myocardial pacing leads with magnetic resonance imaging: an ex vivo tissue study.

Authors:  Alexander Pfeil; Stefanie Drobnik; Reinhard Rzanny; Anas Aboud; Joachim Böttcher; Peter Schmidt; Christian Ortmann; Gita Mall; Khosro Hekmat; Bernhard Brehm; Juergen Reichenbach; Thomas E Mayer; Gunter Wolf; Andreas Hansch
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-24       Impact factor: 2.357

2.  The brain is hypothermic in patients with mitochondrial diseases.

Authors:  Mario Rango; Andrea Arighi; Cristiana Bonifati; Roberto Del Bo; Giacomo Comi; Nereo Bresolin
Journal:  J Cereb Blood Flow Metab       Date:  2014-03-12       Impact factor: 6.200

Review 3.  Image-guided thermal ablation with MR-based thermometry.

Authors:  Mingming Zhu; Ziqi Sun; Chin K Ng
Journal:  Quant Imaging Med Surg       Date:  2017-06

4.  Simian immunodeficiency virus transiently increases brain temperature in rhesus monkeys: detection with magnetic resonance spectroscopy thermometry.

Authors:  Dionyssios Mintzopoulos; Eva-Maria Ratai; Julian He; Ramon Gilberto Gonzalez; Marc J Kaufman
Journal:  Magn Reson Med       Date:  2019-01-16       Impact factor: 4.668

5.  Application of mixed spin iMQCs for temperature and chemical-selective imaging.

Authors:  Elizabeth R Jenista; Gigi Galiana; Rosa T Branca; Pavel S Yarmolenko; Ashley M Stokes; Mark W Dewhirst; Warren S Warren
Journal:  J Magn Reson       Date:  2010-02-25       Impact factor: 2.229

6.  Optimization of Single Voxel MR Spectroscopy Sequence Parameters and Data Analysis Methods for Thermometry in Deep Hyperthermia Treatments.

Authors:  J Hartmann; J Gellermann; T Brandt; M Schmidt; S Pyatykh; J Hesser; O Ott; R Fietkau; C Bert
Journal:  Technol Cancer Res Treat       Date:  2016-07-14

7.  Conditional Human Immunodeficiency Virus Transactivator of Transcription Protein Expression Induces Depression-like Effects and Oxidative Stress.

Authors:  Jay P McLaughlin; Jason J Paris; Dionyssios Mintzopoulos; Kristen A Hymel; Jae K Kim; Thomas J Cirino; Timothy E Gillis; Shainnel O Eans; Gordana D Vitaliano; Jessica M Medina; Richard C Krapf; Heather M Stacy; Marc J Kaufman
Journal:  Biol Psychiatry Cogn Neurosci Neuroimaging       Date:  2017-04-20

8.  An In Vivo Assessment of Regional Brain Temperature during Whole-Body Cooling for Neonatal Encephalopathy.

Authors:  Tai-Wei Wu; Jessica L Wisnowski; Robert F Geisler; Aaron Reitman; Eugenia Ho; Benita Tamrazi; Rachel Chapman; Stefan Blüml
Journal:  J Pediatr       Date:  2020-02-20       Impact factor: 4.406

9.  Lipid-shelled vehicles: engineering for ultrasound molecular imaging and drug delivery.

Authors:  Katherine W Ferrara; Mark A Borden; Hua Zhang
Journal:  Acc Chem Res       Date:  2009-07-21       Impact factor: 22.384

Review 10.  Magnetic resonance spectroscopy studies of substance use disorders: Current landscape and potential future directions.

Authors:  Stephen J Kohut; Marc J Kaufman
Journal:  Pharmacol Biochem Behav       Date:  2020-12-14       Impact factor: 3.533

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.