1H-spectroscopic imaging with read gradient during acquisition in inhomogeneous fields: analysis, measurement strategy, and data processing.

J Weis1, A Ericsson, A Hemmingsson.   

Abstract

The proton magnetic resonance spectroscopic imaging techniques that use read gradient during acquisition produce proton spectra with high spatial and moderately high spectroscopic resolution in a reasonable time for in vivo applications. These techniques suffer mainly from the spatial and spectral distortions caused by the convolution of spectral/spatial information (chemical-shift artifacts) and from the spectral shifts caused by static magnetic field inhomogeneities. The investigators analyze the chemical-shift artifacts in the presence of nonnegligible static magnetic field inhomogeneities and propose a postdetection processing scheme to correct for such effects. Spectral artifacts caused by chemical shifts, spectral line overlapping, streak broadening, and magnetic field inhomogeneities are discussed. The postdetection data processing scheme is demonstrated on measurements of a phantom as well as a human leg.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9351024     DOI: 10.1007/bf02594583

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  25 in total

1.  A fast spectroscopic imaging method using a blipped phase encode gradient.

Authors:  P Webb; D Spielman; A Macovski
Journal:  Magn Reson Med       Date:  1989-12       Impact factor: 4.668

2.  Simulation of the influence of magnetic field inhomogeneity and distortion correction in MR imaging.

Authors:  J Weis; L Budinský
Journal:  Magn Reson Imaging       Date:  1990       Impact factor: 2.546

3.  Three-dimensional spectroscopic imaging with time-varying gradients.

Authors:  E Adalsteinsson; P Irarrazabal; D M Spielman; A Macovski
Journal:  Magn Reson Med       Date:  1995-04       Impact factor: 4.668

4.  High speed 1H spectroscopic imaging in human brain by echo planar spatial-spectral encoding.

Authors:  S Posse; G Tedeschi; R Risinger; R Ogg; D Le Bihan
Journal:  Magn Reson Med       Date:  1995-01       Impact factor: 4.668

5.  A method for chemical shift imaging: demonstration of bone marrow involvement with proton chemical shift imaging.

Authors:  R E Sepponen; J T Sipponen; J I Tanttu
Journal:  J Comput Assist Tomogr       Date:  1984-08       Impact factor: 1.826

6.  Chemical-shift artifact correction scheme using echo-time encoding technique.

Authors:  Z H Cho; O Nalcioglu; H W Park; J B Ra; S K Hilal
Journal:  Magn Reson Med       Date:  1985-06       Impact factor: 4.668

7.  Water referencing for spectroscopic imaging.

Authors:  D Spielman; P Webb; A Macovski
Journal:  Magn Reson Med       Date:  1989-10       Impact factor: 4.668

8.  Measurements of magnetic field variations in the human brain using a 3D-FT multiple gradient echo technique.

Authors:  A Ericsson; J Weis; A Hemmingsson; M Wikström; G O Sperber
Journal:  Magn Reson Med       Date:  1995-02       Impact factor: 4.668

9.  Nickel-doped agarose gel phantoms in MR imaging.

Authors:  J O Christoffersson; L E Olsson; S Sjöberg
Journal:  Acta Radiol       Date:  1991-09       Impact factor: 1.990

10.  Comparison of localized proton NMR signals of skeletal muscle and fat tissue in vivo: two lipid compartments in muscle tissue.

Authors:  F Schick; B Eismann; W I Jung; H Bongers; M Bunse; O Lutz
Journal:  Magn Reson Med       Date:  1993-02       Impact factor: 4.668

View more
  3 in total

1.  Spectroscopic imaging of bone marrow composition in vertebral bodies.

Authors:  J Weis; I Ciray; A Ericsson; H Lindman; G Aström; H Ahlström; A Hemmingsson
Journal:  MAGMA       Date:  2001-08       Impact factor: 2.310

2.  A simple method for mapping the B1 field distribution of linear RF coils.

Authors:  Jan Weis; Peter Andris; Ivan Frollo; Håkan Ahlström
Journal:  MAGMA       Date:  2005-12-13       Impact factor: 2.310

3.  High-resolution echo-planar spectroscopic imaging of the human calf.

Authors:  Jan Weis; Morten Bruvold; Francisco Ortiz-Nieto; Håkan Ahlström
Journal:  PLoS One       Date:  2014-01-30       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.