Literature DB >> 17329581

Marginal bone levels measured in film and digital radiographs corrected for attenuation and visual response: an in vivo study.

G Li1, P E Engström, K Nasström, Z Y Lü, G Sanderink, U Welander.   

Abstract

OBJECTIVE: To compare the accuracy and precision of measurements on marginal bone levels in differently processed digital radiographs and in film-based radiographs.
METHODS: Twenty-one patients with a diagnosis of chronic periodontitis were included in this study. Periapical radiographs were exposed with the Dixi digital intraoral radiographic system (Planmeca Oy, Helsinki, Finland) and the F-speed Film (Insight, Eastman-Kodak Co., Rochester, NY), respectively. Digital radiographs were subsequently processed into two sets: (a) correction for attenuation and visual response and (b) the same correction but with an additional shift in grey levels. Patients had periodontal surgery immediately after the radiographs were exposed. The vertical distance from cementoenamel junction to the most apical part of the marginal bone was assessed. The measurements were then employed as reference standard and subtracted by the vertical distance from radiographs accordingly. Altogether, 47 sites were evaluated. Seven observers were employed for evaluation under the same viewing conditions. ANOVA was employed for statistical analysis.
RESULTS: No significant differences were found between the absolute differences of the vertical distance obtained from radiographs to their corresponding reference standards when comparing differently processed digital radiographs, but the absolute differences were significantly smaller in digital radiographs than in films. Interobserver variances were not significant.
CONCLUSION: Digital radiographs have a favourable measurement accuracy compared with film radiographs when assessing marginal bone levels.

Entities:  

Mesh:

Year:  2007        PMID: 17329581     DOI: 10.1259/dmfr/28315324

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  7 in total

1.  A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 1: the influence of X-ray generator on periodontal measurements using conventional and digital receptors.

Authors:  Bart Vandenberghe; Livia Corpas; Hilde Bosmans; Jie Yang; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2010-05-05       Impact factor: 3.573

2.  A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 2: the influence of intra-oral image receptor on periodontal measurements.

Authors:  Bart Vandenberghe; Hilde Bosmans; Jie Yang; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2010-05-12       Impact factor: 3.573

3.  Influence of individual brightness and contrast adjustment on accuracy of radiographic measurements of infrabony defects.

Authors:  D Tihanyi; I Gera; P Eickholz
Journal:  Dentomaxillofac Radiol       Date:  2011-03       Impact factor: 2.419

4.  Assessment of periodontal bone level revisited: a controlled study on the diagnostic accuracy of clinical evaluation methods and intra-oral radiography.

Authors:  Véronique Christiaens; Hugo De Bruyn; Eric Thevissen; Sebastiaan Koole; Melissa Dierens; Jan Cosyn
Journal:  Clin Oral Investig       Date:  2017-05-26       Impact factor: 3.573

5.  Comparison of diagnostic accuracy of conventional intraoral periapical and direct digital radiographs in detecting interdental bone loss.

Authors:  S R Ashwinirani; Girish Suragimath; H P Jaishankar; Prasad Kulkarni; Shobha C Bijjaragi; Varsha Ajit Sangle
Journal:  J Clin Diagn Res       Date:  2015-02-01

6.  The influence of tube potential on periodontal bone level measurements and subjective image quality using a digital photostimulable storage phosphor sensor.

Authors:  Bart Vandenberghe; Reinhilde Jacobs
Journal:  J Oral Maxillofac Res       Date:  2010-04-01

7.  Evaluation of diagnostic accuracy of conventional and digital periapical radiography, panoramic radiography, and cone-beam computed tomography in the assessment of alveolar bone loss.

Authors:  Wilton Mitsunari Takeshita; Lilian Cristina Vessoni Iwaki; Mariliani Chicarelli Da Silva; Renata Hernandes Tonin
Journal:  Contemp Clin Dent       Date:  2014-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.