Literature DB >> 1732274

Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses.

G A Engh1, K A Dwyer, C K Hanes.   

Abstract

We examined 86 polyethylene inserts, retrieved from total and unicompartmental knee prostheses after an average of 39.5 months in situ, grading them from 0 to 3 for seven modes of polyethylene degradation. Severe wear, with delamination or deformation, was observed in 51% of the implants, and was associated with time in situ, lack of congruency, thin polyethylene, third-body wear debris, and heat-pressed polyethylene. Significant under-surface cold flow was identified in some areas of unsupported polyethylene, and was associated with delamination in the load-bearing areas of thin inserts above screw holes in the underlying metal tray. We recommend the use of thicker polyethylene inserts, particularly in young, active patients and in designs with screw holes in the tibial baseplate. Thin polyethylene inserts which are at risk for accelerated wear and premature failure should be monitored radiographically at annual intervals.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1732274

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  41 in total

1.  Durability of a cruciate-retaining TKA with modular tibial trays at 20 years.

Authors:  John J Callaghan; Mitchell W Beckert; David W Hennessy; Devon D Goetz; Scott S Kelley
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

2.  Finite element analysis: a comparison of an all-polyethylene tibial implant and its metal-backed equivalent.

Authors:  S M Thompson; D Yohuno; W N Bradley; A D Crocombe
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-12-22       Impact factor: 4.342

3.  Posteromedial compartment cement extrusion after unicompartmental knee arthroplasty treated by arthroscopy: a case report.

Authors:  Weon Yoo Kim; Mohamed Shafi; Young Yul Kim; Jin Young Kim; Yun Kyoung Cho; Chang Whan Han
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-05-05       Impact factor: 4.342

4.  Severe metallosis after unicompartmental knee arthroplasty.

Authors:  Vicente Sanchis-Alfonso
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-10-07       Impact factor: 4.342

5.  International multi-centre survivorship analysis of mobile bearing total knee arthroplasty.

Authors:  James B Stiehl; Karel J Hamelynck; Paul E Voorhorst
Journal:  Int Orthop       Date:  2006-03-18       Impact factor: 3.075

6.  Hybrid total knee arthroplasty: 13-year survivorship of AGC total knee systems with average 7 years followup.

Authors:  Philip M Faris; E Michael Keating; Alex Farris; John B Meding; Merrill A Ritter
Journal:  Clin Orthop Relat Res       Date:  2008-03-07       Impact factor: 4.176

7.  The Self-Aligning knee prosthesis: clinical and radiological outcome and survival analysis at 5-year follow up.

Authors:  M J F Diks; P G Anderson; J C A D Janssen; G van Stralen; A B Wymenga
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-11-14       Impact factor: 4.342

8.  Early failure of a mobile-bearing unicompartmental knee replacement.

Authors:  Mateen H Arastu; J Vijayaraghavan; H Chissell; J B Hull; J H Newman; J R Robinson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-03-31       Impact factor: 4.342

9.  Improved positioning of the tibial component in unicompartmental knee arthroplasty with patient-specific cutting blocks.

Authors:  M L Dao Trong; C Diezi; G Goerres; N Helmy
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-01-17       Impact factor: 4.342

10.  Current Total Knee Designs: Does Baseplate Roughness or Locking Mechanism Design Affect Polyethylene Backside Wear?

Authors:  Zachary W Sisko; Matthew G Teeter; Brent A Lanting; James L Howard; Richard W McCalden; Douglas D Naudie; Steven J MacDonald; Edward M Vasarhelyi
Journal:  Clin Orthop Relat Res       Date:  2017-09-13       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.