Literature DB >> 1732260

The morphology of the proximal femur. A three-dimensional radiographic analysis.

P J Rubin1, P F Leyvraz, J M Aubaniac, J N Argenson, P Estève, B de Roguin.   

Abstract

Biological fixation of cementless femoral implants requires primary stability by optimal fit in the proximal femur. The anatomy of the bone must then be known precisely. We analysed in vitro the accuracy of bone measurements of 32 femurs and compared the dimensions obtained from radiographs and CT scans with the true anatomical dimensions. Standard radiographs gave only a rough approximation of femoral geometry (mean difference: 2.4 +/- 1.4 mm) insufficiently accurate to allow selection of the best fitting prosthesis from a range of sizes and altogether inadequate to design a custom-made prosthesis. CT scans give greater accuracy (mean difference: 0.8 +/- 0.7 mm) in our experimental conditions, but in clinical practice additional sources of error exist.

Entities:  

Mesh:

Year:  1992        PMID: 1732260

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  47 in total

1.  Re: Increased anteversion of press-fit femoral stems compared with anatomic femur.

Authors:  Michael Wettstein; Elyazid Mouhsine
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

Review 2.  The femoral neck-shaft angle on plain radiographs: a systematic review.

Authors:  Christoph Kolja Boese; Jens Dargel; Johannes Oppermann; Peer Eysel; Max Joseph Scheyerer; Jan Bredow; Philipp Lechler
Journal:  Skeletal Radiol       Date:  2015-08-25       Impact factor: 2.199

3.  Usefullness of three-dimensional templating software to quantify the contact state between implant and femur in total hip arthroplasty.

Authors:  Daisuke Inoue; Tamon Kabata; Toru Maeda; Yoshitomo Kajino; Kenji Fujita; Kazuhiro Hasegawa; Takashi Yamamoto; Tomoharu Takagi; Takaaki Ohmori; Hiroyuki Tsuchiya
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-11-05

4.  Radiograph-based femur morphing method.

Authors:  E M Zanetti; V Crupi; C Bignardi; P M Calderale
Journal:  Med Biol Eng Comput       Date:  2005-03       Impact factor: 2.602

5.  Evaluation of proximal femoral geometry in plain anterior-posterior radiograph in eastern-Indian population.

Authors:  Sanchita Roy; Rajib Kundu; Shyamalendu Medda; Avanish Gupta; Baljit Kaur Nanrah
Journal:  J Clin Diagn Res       Date:  2014-09-20

6.  Morphometry of Proximal Femur in Indian Population.

Authors:  Minakshi Verma; Sheetal Joshi; Anita Tuli; Shashi Raheja; Priyanka Jain; Priyanka Srivastava
Journal:  J Clin Diagn Res       Date:  2017-02-01

7.  [Custom made hip prostheses : principles and design].

Authors:  J -N Argenson; J -M Aubaniac
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-03-10

8.  A surrogate long-bone model with osteoporotic material properties for biomechanical testing of fracture implants.

Authors:  Mark B Sommers; Daniel C Fitzpatrick; Steven M Madey; Corey Vande Zanderschulp; Michael Bottlang
Journal:  J Biomech       Date:  2007-06-18       Impact factor: 2.712

9.  Basic science considerations in primary total hip replacement arthroplasty.

Authors:  Saqeb B Mirza; Douglas G Dunlop; Sukhmeet S Panesar; Syed G Naqvi; Shafat Gangoo; Saif Salih
Journal:  Open Orthop J       Date:  2010-05-11

10.  Uncemented custom femoral components in hip arthroplasty. A prospective clinical study of 191 hips followed for at least 7 years.

Authors:  Pål Benum; Arild Aamodt
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.