Literature DB >> 17309875

Dose-area product measurements and determination of conversion coefficients for the estimation of effective dose in dental lateral cephalometric radiology.

H K Looe1, F Eenboom, N Chofor, A Pfaffenberger, M Sering, A Rühmann, A Poplawski, K Willborn, B Poppe.   

Abstract

A study has been carried out to propose diagnostic reference levels (DRLs) for lateral cephalometric radiology in Germany based on the dose-area product (DAP). DRLs were proposed separately for child and adult exposure settings which are 26.4 and 32.6 mGy cm2, respectively. Organ absorbed doses from lateral cephalometric radiology were also measured using thermoluminescence detectors (TLDs) and an adult anthropomorphic phantom specially design for dosimetric study in dental radiology. Effective doses were then calculated using three different techniques where the salivary gland and brain tissue were given different weighting factors. Conversion coefficients for estimating effective dose from DAP value derived in this study range from 0.042 to 0.149 microSv/mGy cm2.

Entities:  

Mesh:

Year:  2007        PMID: 17309875     DOI: 10.1093/rpd/ncm143

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  7 in total

1.  Necessity of 3D visualization for the removal of lower wisdom teeth: required sample size to prove non-inferiority of panoramic radiography compared to CBCT.

Authors:  Felix Roeder; Daniel Wachtlin; Ralf Schulze
Journal:  Clin Oral Investig       Date:  2011-04-26       Impact factor: 3.573

2.  National reference doses for dental cephalometric radiography.

Authors:  J R Holroyd
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

3.  Dose distribution for dental cone beam CT and its implication for defining a dose index.

Authors:  R Pauwels; C Theodorakou; A Walker; H Bosmans; R Jacobs; K Horner; R Bogaerts
Journal:  Dentomaxillofac Radiol       Date:  2012-06-29       Impact factor: 2.419

4.  Assessment of Regional Diagnostic Reference Levels in Dental Radiography in Tamil Nadu.

Authors:  Amal Jose; A Saravana Kumar; K N Govindarajan; Sunil Dutt Sharma
Journal:  J Med Phys       Date:  2022-03-31

5.  Assessing anteroposterior basal bone discrepancy with the Dental Aesthetic Index.

Authors:  Boyen Huang; Katsu Takahashi; Toru Yamazaki; Kazuyuki Saito; Masashi Yamori; Keita Asai; Yusuke Yoshikawa; Hiroshi Kamioka; Takashi Yamashiro; Kazuhisa Bessho
Journal:  Angle Orthod       Date:  2012-10-18       Impact factor: 2.079

6.  Diagnostic reference levels in intraoral dental radiography in Korea.

Authors:  Eun-Kyung Kim; Won-Jeong Han; Jin-Woo Choi; Yun-Hoa Jung; Suk-Ja Yoon; Jae-Seo Lee
Journal:  Imaging Sci Dent       Date:  2012-12-23

7.  Conversion coefficients for the estimation of effective dose in cone-beam CT.

Authors:  Dong-Soo Kim; Oyuntugs Rashsuren; Eun-Kyung Kim
Journal:  Imaging Sci Dent       Date:  2014-03-19
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.