Literature DB >> 22101581

National reference doses for dental cephalometric radiography.

J R Holroyd1.   

Abstract

OBJECTIVES: Diagnostic reference levels (DRLs) are an important tool in the optimisation of clinical radiography. Although national DRLs are provided for many diagnostic procedures including dental intra-oral radiography, there are currently no national DRLs set for cephalometric radiography. In the absence of formal national DRLs, the Health Protection Agency (HPA) has previously published National Reference Doses (NRDs) covering a wide range of diagnostic X-ray examinations. The aim of this study was to determine provisional NRDs for cephalometric radiography.
METHODS: Measurements made by the Dental X-ray Protection Service (DXPS) of the HPA, as part of the cephalometric X-ray equipment testing service provided to dentists and dental trade companies throughout the UK, were used to derive provisional NRDs.
RESULTS: Dose-area product measurements were made on 42 X-ray sets. Third quartile dose-area product values for adult and child lateral cephalometric radiography were found to be 41 mGy cm² and 25 mGy cm², respectively, with individual measurements ranging from 3 mGy cm² to 108 mGy cm².
CONCLUSION: This report proposes provisional NRDs of 40 mGy cm² and 25 mGy cm² for adult and child lateral cephalometric radiographs, respectively; these doses could be considered by employers when establishing their local DRLs.

Entities:  

Mesh:

Year:  2011        PMID: 22101581      PMCID: PMC3473818          DOI: 10.1259/bjr/26420990

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  5 in total

1.  Reference doses for dental radiography.

Authors:  I D Napier
Journal:  Br Dent J       Date:  1999-04-24       Impact factor: 1.626

2.  Reference values for diagnostic radiology: application and impact.

Authors:  Joel E Gray; Benjamin R Archer; Priscilla F Butler; Barry B Hobbs; Fred A Mettler; Robert J Pizzutiello; Beth A Schueler; Keith J Strauss; Orhan H Suleiman; Martin J Yaffe
Journal:  Radiology       Date:  2005-03-09       Impact factor: 11.105

3.  Dose-area product measurements and determination of conversion coefficients for the estimation of effective dose in dental lateral cephalometric radiology.

Authors:  H K Looe; F Eenboom; N Chofor; A Pfaffenberger; M Sering; A Rühmann; A Poplawski; K Willborn; B Poppe
Journal:  Radiat Prot Dosimetry       Date:  2007-02-18       Impact factor: 0.972

4.  Reference level for patient dose in dental skull lateral teleradiography.

Authors:  L Gonzalez; R Fernandez; V Ziraldo; E Vano; R Ortega
Journal:  Br J Radiol       Date:  2004-09       Impact factor: 3.039

5.  Radiation doses of collimated vs non-collimated cephalometric exposures.

Authors:  F Gijbels; G Sanderink; J Wyatt; J Van Dam; B Nowak; R Jacobs
Journal:  Dentomaxillofac Radiol       Date:  2003-03       Impact factor: 2.419

  5 in total
  2 in total

1.  Korean dentists' perceptions and attitudes regarding radiation safety and protection.

Authors:  Seo-Young An; Kyung-Min Lee; Jae-Seo Lee
Journal:  Dentomaxillofac Radiol       Date:  2018-01-31       Impact factor: 2.419

2.  Assessment of Regional Diagnostic Reference Levels in Dental Radiography in Tamil Nadu.

Authors:  Amal Jose; A Saravana Kumar; K N Govindarajan; Sunil Dutt Sharma
Journal:  J Med Phys       Date:  2022-03-31
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.