Literature DB >> 17304413

Benign and malignant breast lesions: efficacy of real time contrast-enhanced ultrasound vs. magnetic resonance imaging.

P Ricci1, V Cantisani, L Ballesio, E Pagliara, E Sallusti, F M Drudi, F Trippa, F Calascibetta, S M Erturk, M Modesti, R Passariello.   

Abstract

PURPOSE: To assess the efficacy of low mechanical index (MI) real time grey scale contrast-enhanced US (CEUS) in the differentiation of breast lesions in comparison to Magnetic Resonance Imaging (MRI).
MATERIALS AND METHODS: 50 lesions previously detected at mammography or conventional US were evaluated by means of CEUS and MRI. Contrast-enhanced examinations were performed with a dedicated equipment (Esatune, Esaote, Genoa, Italy), before and after injection of 4.8 ml of Sonovue (Bracco, Milan, Italy). MRI was conducted with a 1.5 T equipment (Siemens Vision Plus, Erlangen, Germany) with bilateral dedicated superficial coil, on T2w STIR and 3D Flash T1w before and 1, 2, 3, 4, 5 minutes after the administration of contrast agent (Gd-DTPA, 1.5 ml/kg). Wash-in and wash-out curves were assessed for both procedures. A specific sonographic quantification software (Qontrast, Bracco, Milan, Italy), based on pixel by pixel signal intensity over time, was used to obtain contrast-enhanced sonographic perfusion maps for each lesion. Mc Nemar test was then calculated.
RESULTS: 24 invasive ductal carcinomas, 18 fibroadenomas, 4 fibro-cystic dysplasias, 1 mucinous carcinoma, 1 invasive ducto-lobular carcinoma, 1 intraductal florid papillomatosis and 1 phylloides tumour were diagnosed. Contrast-enhanced sonographic patterns correlated well with those provided by MRI. Sensitivity, specificity, and accuracy of US were: 69.2 %, 66.7 %, and 68 %, respectively. According to the different contrast enhancement patterns and the resulting perfusion maps, all the malignant lesions and 9 out of 12 benign lesions were correctly diagnosed, thus resulting in 87.5 % of specificity and 100 % of sensitivity. Regarding the specificity, there is no difference between US and CEUS with McNemar (p = 0.18). Regarding sensitivity, the difference between contrast-enhanced US and US is significant as calculated with McNemar test (p = 0.013). The three lesions which were incorrectly classified as malignant were two hypervascularised fibroadenomas in young women and a phylloides tumour.
CONCLUSION: CEUS seems to be a reliable method to differentiate breast lesions, since it provides typical enhancement patterns. Contrast sonographic perfusion curves correlate well with MRI wash in--wash out curves.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17304413     DOI: 10.1055/s-2006-927226

Source DB:  PubMed          Journal:  Ultraschall Med        ISSN: 0172-4614            Impact factor:   6.548


  22 in total

1.  Study of neurinomas with ultrasound contrast media: review of a case series to identify characteristic imaging patterns.

Authors:  A De Marchi; S Pozza; R Sutera; E M Brach del Prever; M Petraz; C Sena; A Linari; C Faletti
Journal:  Radiol Med       Date:  2011-03-07       Impact factor: 3.469

2.  Tumor size of breast invasive ductal cancer measured with contrast-enhanced ultrasound predicts regional lymph node metastasis and N stage.

Authors:  Zhiyuan Wang; Qichang Zhou; Jun Liu; Shichu Tang; Xia Liang; Zhengyu Zhou; Ying He; Hui Peng; Yuanming Xiao
Journal:  Int J Clin Exp Pathol       Date:  2014-09-15

3.  Predictive model for contrast-enhanced ultrasound of the breast: Is it feasible in malignant risk assessment of breast imaging reporting and data system 4 lesions?

Authors:  Jun Luo; Ji-Dong Chen; Qing Chen; Lin-Xian Yue; Guo Zhou; Cheng Lan; Yi Li; Chi-Hua Wu; Jing-Qiao Lu
Journal:  World J Radiol       Date:  2016-06-28

Review 4.  Ultrasound Imaging Technologies for Breast Cancer Detection and Management: A Review.

Authors:  Rongrong Guo; Guolan Lu; Binjie Qin; Baowei Fei
Journal:  Ultrasound Med Biol       Date:  2017-10-26       Impact factor: 2.998

5.  Hollow silica and silica-boron nano/microparticles for contrast-enhanced ultrasound to detect small tumors.

Authors:  Alexander Liberman; H Paul Martinez; Casey N Ta; Christopher V Barback; Robert F Mattrey; Yuko Kono; Sarah L Blair; William C Trogler; Andrew C Kummel; Zhe Wu
Journal:  Biomaterials       Date:  2012-04-11       Impact factor: 12.479

6.  Power Doppler ultrasonography with time-signal intensity curves in monitoring hepatocellular carcinoma and liver metastases after intralesional therapy.

Authors:  R Farina; F Pennisi; G Mazzone; M Pennisi; G Riva; P V Foti; C Puglisi; G C Ettorre
Journal:  Radiol Med       Date:  2008-09-26       Impact factor: 3.469

Review 7.  Developments in musculoskeletal ultrasound and clinical applications.

Authors:  Andrea S Klauser; Philippe Peetrons
Journal:  Skeletal Radiol       Date:  2010-11       Impact factor: 2.199

8.  Contrast-enhanced US and MRI for assessing the response of breast cancer to neoadjuvant chemotherapy().

Authors:  B Corcioni; L Santilli; S Quercia; C Zamagni; D Santini; M Taffurelli; S Mignani
Journal:  J Ultrasound       Date:  2008-11-14

9.  First-in-Human Study of Acoustic Angiography in the Breast and Peripheral Vasculature.

Authors:  Sarah E Shelton; Brooks D Lindsey; Paul A Dayton; Yueh Z Lee
Journal:  Ultrasound Med Biol       Date:  2017-10-02       Impact factor: 2.998

10.  Diagnostic value of contrast-enhanced ultrasound parametric imaging in breast tumors.

Authors:  Zhang Yuan; Jiang Quan; Zhang Yunxiao; Chen Jian; He Zhu; Gong Liping
Journal:  J Breast Cancer       Date:  2013-06-28       Impact factor: 3.588

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.