On- and off-resonance T(1rho) MRI in acute cerebral ischemia of the rat.

Olli H J Gröhn1, Heidi I Mäkelä, Jouko A Lukkarinen, Lance DelaBarre, Joseph Lin, Michael Garwood, Risto A Kauppinen.   

Abstract

The ability of on-resonance T(1rho) (T(1rho)) and off-resonance T(1rho) (T(1rho)(off)) measurements to indicate acute cerebral ischemia in a rat model of transient middle cerebral artery (MCA) occlusion was investigated at 4.7 T. T(1rho) was determined with B(1) fields of 0.4, 0.8, and 1.6 G, and T(1rho)(off) with five offset frequencies ((Delta)omega) ranging from 0-7.5 kHz at B(1) of 0.4 G, yielding effective B(1) (B(eff)) from 0.4 to 1.8 G. Diffusion, T(1), and T(2) were also quantified. Both T(1rho) and T(1rho)(off) acquired with (Delta)(o)< 2.5 kHz showed positive contrast during the first hours of MCA occlusion in the ischemic tissue delineated by low diffusion. Interestingly, T(1rho)(off) contrast acquired with (Delta)omega > 2.5 kHz was clearly less sensitive to ischemic alterations, and developed with a delayed time course. This discrepancy is thought to be a consequence of the frequency dependency of cross-relaxation during irradiation with spin-lock pulses. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2003        PMID: 12509834     DOI: 10.1002/mrm.10356

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  14 in total

Review 1.  Errors in quantitative T1rho imaging and the correction methods.

Authors:  Weitian Chen
Journal:  Quant Imaging Med Surg       Date:  2015-08

2.  Compensation for spin-lock artifacts using an off-resonance rotary echo in T1rhooff-weighted imaging.

Authors:  Walter R T Witschey; Arijitt Borthakur; Mark A Elliott; Eric Mellon; Sampreet Niyogi; Chenyang Wang; Ravinder Reddy
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

3.  Artifacts in T1 rho-weighted imaging: compensation for B(1) and B(0) field imperfections.

Authors:  Walter R T Witschey; Arijitt Borthakur; Mark A Elliott; Eric Mellon; Sampreet Niyogi; Daniel J Wallman; Chenyang Wang; Ravinder Reddy
Journal:  J Magn Reson       Date:  2007-01-26       Impact factor: 2.229

4.  Quantitative prediction of ischemic stroke tissue fate.

Authors:  Qiang Shen; Timothy Q Duong
Journal:  NMR Biomed       Date:  2008-10       Impact factor: 4.044

5.  Spin-lock imaging of early tissue pH changes in ischemic rat brain.

Authors:  Zhongliang Zu; Aqeela Afzal; Hua Li; Jingping Xie; John C Gore
Journal:  NMR Biomed       Date:  2018-02-09       Impact factor: 4.044

6.  Quantitative assessment of water pools by T 1 rho and T 2 rho MRI in acute cerebral ischemia of the rat.

Authors:  Kimmo T Jokivarsi; Juha-Pekka Niskanen; Shalom Michaeli; Heidi I Gröhn; Michael Garwood; Risto A Kauppinen; Olli H Gröhn
Journal:  J Cereb Blood Flow Metab       Date:  2008-10-01       Impact factor: 6.200

7.  Quantitative chemical exchange sensitive MRI using irradiation with toggling inversion preparation.

Authors:  Tao Jin; Seong-Gi Kim
Journal:  Magn Reson Med       Date:  2012-08-06       Impact factor: 4.668

8.  Water spin dynamics during apoptotic cell death in glioma gene therapy probed by T1rho and T2rho.

Authors:  A Sierra; S Michaeli; J-P Niskanen; P K Valonen; H I Gröhn; S Ylä-Herttuala; M Garwood; O H Gröhn
Journal:  Magn Reson Med       Date:  2008-06       Impact factor: 4.668

9.  Spin-locked balanced steady-state free-precession (slSSFP).

Authors:  Walter R T Witschey; Ari Borthakur; Mark A Elliott; Jeremy Magland; Erin L McArdle; Andrew Wheaton; Ravinder Reddy
Journal:  Magn Reson Med       Date:  2009-10       Impact factor: 4.668

10.  T1rho-prepared balanced gradient echo for rapid 3D T1rho MRI.

Authors:  Walter R T Witschey; Arijitt Borthakur; Mark A Elliott; Matthew Fenty; Matthew A Sochor; Chenyang Wang; Ravinder Reddy
Journal:  J Magn Reson Imaging       Date:  2008-09       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.