Literature DB >> 17290023

An evaluation of the errors in cephalometric measurements on scanned cephalometric images and conventional tracings.

Korkmaz Sayinsu1, Fulya Isik, Göksu Trakyali, Tülin Arun.   

Abstract

The aim of this investigation was to compare the classic method of tracing by hand with a computerized method, where the lateral cephalograms were scanned at 300 dpi and digitized onscreen. The inter- and intra-observer errors were investigated for tracing and digitizing errors. Thirty lateral cephalograms were scanned into digital format at 300 dpi, displayed on a high-resolution monitor, and processed twice by two operators using Dolphin Imaging Software 9.0. The same radiographs were then traced and measured manually by the same two operators. Intraclass correlation coefficients (ICC) were used for detecting intra- and inter-rater agreement for each cephalometric variable. The results showed that each operator was consistent in the repeated measurements; all ICC were greater than or equal to 0.90 and none of the 95 per cent confidence limits on these ICC had a lower boundary less than 0.84. Inter-rater agreement also showed correlation coefficients greater than 0.75. The angles, maxillary height, maxillary depth, y-axis, FMA, and nasolabial, and the distance N perpendicular point A had a wider reliability interval and lower correlation than the other parameters tested. The findings demonstrated that the use of computer software for cephalometric analysis carried out on scanned images does not increase the measurement error when compared with hand tracing.

Entities:  

Mesh:

Year:  2007        PMID: 17290023     DOI: 10.1093/ejo/cjl065

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  20 in total

1.  The reliability and reproducibility of cephalometric measurements: a comparison of conventional and digital methods.

Authors:  S F Albarakati; K S Kula; A A Ghoneima
Journal:  Dentomaxillofac Radiol       Date:  2012-01       Impact factor: 2.419

2.  Influence of a programme of professional calibration in the variability of landmark identification using cone beam computed tomography-synthesized and conventional radiographic cephalograms.

Authors:  E L Delamare; G S Liedke; M B Vizzotto; H L D da Silveira; J L D Ribeiro; H E D Silveira
Journal:  Dentomaxillofac Radiol       Date:  2010-10       Impact factor: 2.419

3.  The effect of premolar extractions on incisor position and soft tissue profile in patients with Class II, Division 1 malocclusion.

Authors:  Catharina Weyrich; Jörg A Lisson
Journal:  J Orofac Orthop       Date:  2009-03-26       Impact factor: 1.938

4.  The applicability of a non-anatomical soft and hard tissue centroid line (S&H centroid) in cephalometrics.

Authors:  Ibrahim S Al-Shahrani; Khalid M Al-Balkhi; Abdulaziz Al-Madi
Journal:  Saudi Dent J       Date:  2010-02-06

5.  Comparative evaluation of cephalometric measurements of monitor-displayed images by Nemoceph software and its hard copy by manual tracing.

Authors:  Tripti Tikku; Rohit Khanna; R P Maurya; Kamna Srivastava; Rastra Bhushan
Journal:  J Oral Biol Craniofac Res       Date:  2014-01-08

6.  The reliability and reproducibility of an Android cephalometric smartphone application in comparison with the conventional method.

Authors:  Obada M Zamrik; Haluk İşeri
Journal:  Angle Orthod       Date:  2021-03-01       Impact factor: 2.079

7.  Assessing the Reliability of Digitalized Cephalometric Analysis in Comparison with Manual Cephalometric Analysis.

Authors:  Mohammed Umar Farooq; Mohd Asadullah Khan; Shahid Imran; Ayesha Sameera; Arshad Qureshi; Syed Afroz Ahmed; Sujan Kumar; Mohd Aziz Ur Rahman
Journal:  J Clin Diagn Res       Date:  2016-10-01

8.  Quantitative evaluation of patient movement during simulated acquisition of cephalometric radiographs.

Authors:  Kyung-Hoe Huh; Erika Benavides; Young-Tak Jo; Bo-Ram Choi; Won-Jin Yi; Min-Suk Heo; Sam-Sun Lee; Soon-Chul Choi
Journal:  J Digit Imaging       Date:  2011-06       Impact factor: 4.056

9.  Comparison of manual, digital and lateral CBCT cephalometric analyses.

Authors:  Ricardo de Lima Navarro; Paula Vanessa Pedron Oltramari-Navarro; Thais Maria Freire Fernandes; Giovani Fidelis de Oliveira; Ana Cláudia de Castro Ferreira Conti; Marcio Rodrigues de Almeida; Renato Rodrigues de Almeida
Journal:  J Appl Oral Sci       Date:  2013 Mar-Apr       Impact factor: 2.698

10.  Comparative Evaluation of Conventional and OnyxCeph™ Dental Software Measurements on Cephalometric Radiography.

Authors:  Elif İzgi; Filiz Namdar Pekiner
Journal:  Turk J Orthod       Date:  2019-06-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.