Literature DB >> 17285048

Clinical accuracy of cervicothoracic pedicle screw placement: a comparison of the "open" lamino-foraminotomy and computer-assisted techniques.

Gabriel Y F Lee1, Eric M Massicotte, Y Raja Rampersaud.   

Abstract

OBJECTIVE: Posterior transpedicular fixation at the cervicothoracic junction (CTJ) is increasing in popularity. However, the clinical accuracy of pedicle screw placement at the CTJ has not been specifically assessed.
METHODS: Between January 2000 and July 2004, 60 consecutive patients underwent a variety of posterior spinal procedures necessitating pedicle screw placement at C7, T1, and T2. Thirty-two patients had cervicothoracic screws (3.5 to 4.5 mm) placed by an "open" technique (laminectomies or lamino-foraminotomies) and 28 patients with either a closed (before any decompression) 2-dimensional (n=19, fluoroscopy) or 3-dimensional (n=9, CT) computer-assisted technique. Screws were independently assessed for pedicle breach on postoperative CT and scored using a points-based classification system.
RESULTS: The total number of screws placed was 86, 63 and 45 in the open, closed-2-dimensional and closed-3-dimensional groups, respectively. Overall, 61(70.9%), 51(81%), and 40(89%) screws were completely within the pedicle. In the open group, the majority of pedicle breaches were more than 2 mm [n=3 (<2 mm), n=20 (2-4 mm), n=2 (>4 mm)]. Screw violation occurred laterally 11/25(44%), medially 3/25(12%), inferiorly 7/25(28%), and superiorly 4/25(16%). In the closed technique, all breaches were lateral. Seventeen screws (n=11-2-dimensional, n=5-3-dimensional) breached the pedicle by a margin of less than 2 mm and 1 screw (2-dimensional) by 2 to 4 mm. Pedicle screw accuracy was significantly improved with computer-assisted techniques. However, there was no significant difference between the 2-dimensional and 3-dimensional techniques. For all patients, there were no clinically significant screw misplacements, nor any need for screw revision.
CONCLUSIONS: Computer-assisted surgery allows for more accurate placement of pedicle screws at the CTJ. Although a higher proportion of major pedicular breaches occurred in the "open lamina/lamino-foraminotomy" group, no screws required revision in either group.

Entities:  

Mesh:

Year:  2007        PMID: 17285048     DOI: 10.1097/01.bsd.0000211239.21835.ad

Source DB:  PubMed          Journal:  J Spinal Disord Tech        ISSN: 1536-0652


  19 in total

1.  The use of pedicle screw-rod system for the posterior fixation in cervico-thoracic junction.

Authors:  Wonik Cho; Ahmed Shawky Eid; Ung-Kyu Chang
Journal:  J Korean Neurosurg Soc       Date:  2010-07-31

Review 2.  Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies.

Authors:  Nai-Feng Tian; Qi-Shan Huang; Ping Zhou; Yang Zhou; Rui-Kai Wu; Yi Lou; Hua-Zi Xu
Journal:  Eur Spine J       Date:  2010-09-23       Impact factor: 3.134

3.  Pedicle screw fixation of the C7 vertebra using an anteroposterior fluoroscopic imaging technique.

Authors:  Shaunak Desai; Anil Sethi; Christopher C Ninh; Stephen Bartol; Rahul Vaidya
Journal:  Eur Spine J       Date:  2010-07-17       Impact factor: 3.134

4.  Image-guided pedicle screw insertion accuracy: a meta-analysis.

Authors:  Nai-Feng Tian; Hua-Zi Xu
Journal:  Int Orthop       Date:  2009-05-08       Impact factor: 3.075

Review 5.  Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5,992 pedicle screws.

Authors:  Rajeev Verma; Sonal Krishan; Kurt Haendlmayer; A Mohsen
Journal:  Eur Spine J       Date:  2010-01-06       Impact factor: 3.134

Review 6.  The evolution of image-guided lumbosacral spine surgery.

Authors:  Austin C Bourgeois; Austin R Faulkner; Alexander S Pasciak; Yong C Bradley
Journal:  Ann Transl Med       Date:  2015-04

7.  Application of a novel 3D drill template for cervical pedicle screw tunnel design: a cadaveric study.

Authors:  Zhengxi Yu; Guodong Zhang; Xuanhuang Chen; Xu Chen; Changfu Wu; Yijun Lin; Wenhua Huang; Haibin Lin
Journal:  Eur Spine J       Date:  2017-06-10       Impact factor: 3.134

8.  Morphologic evaluation of the thoracic vertebrae for safe free-hand pedicle screw placement in adolescent idiopathic scoliosis: a CT-based anatomical study.

Authors:  Guanyu Cui; Kota Watanabe; Naobumi Hosogane; Takashi Tsuji; Ken Ishii; Masaya Nakamura; Yoshiaki Toyama; Kazuhiro Chiba; Lawrence G Lenke; Morio Matsumoto
Journal:  Surg Radiol Anat       Date:  2011-07-08       Impact factor: 1.246

9.  The intraoperative portable CT scanner-based spinal navigation: a viable option for instrumentation in the region of cervico-thoracic junction.

Authors:  Pavel Barsa; Robert Frőhlich; Miroslav Šercl; Pavel Buchvald; Petr Suchomel
Journal:  Eur Spine J       Date:  2016-03-17       Impact factor: 3.134

10.  Cervical pedicle screw fixation in traumatic cervical subluxation after laminectomy using the pedicle axis view technique under fluoroscopy.

Authors:  Masaaki Machino; Yasutsugu Yukawa; Keigo Ito; Hiroaki Nakashima; Shunsuke Kanbara; Daigo Morita; Fumihiko Kato
Journal:  BMJ Case Rep       Date:  2012-10-10