Literature DB >> 17278498

Optimization of dual-energy imaging systems using generalized NEQ and imaging task.

S Richard1, J H Siewerdsen.   

Abstract

Dual-energy (DE) imaging is a promising advanced application of flat-panel detectors (FPDs) with a potential host of applications ranging from thoracic and cardiac imaging to interventional procedures. The performance of FPD-based DE imaging systems is investigated in this work by incorporating the noise-power spectrum associated with overlying anatomical structures ("anatomical noise" modeled according to a 1/f characteristic) into descriptions of noise-equivalent quanta (NEQ) to yield the generalized NEQ (GNEQ). Signal and noise propagation in the DE imaging chain is modeled by cascaded systems analysis. A Fourier-based description of the imaging task is integrated with the GNEQ to yield a detectability index used as an objective function for optimizing DE image reconstruction, allocation of dose between low- and high-energy images, and selection of low- and high-kVp. Optimal reconstruction and acquisition parameters were found to depend on dose; for example, optimal kVp varied from [60/150] kVp at typical radiographic dose levels (approximately 0.5 mGy entrance surface dose, ESD) but increased to [90/150] kVp at high dose (ESD approximately 5.0 mGy). At very low dose (ESD approximately 0.05 mGy), detectability index indicates an optimal low-energy technique of 60 kVp but was largely insensitive to the choice of high-kVp in the range 120-150 kVp. Similarly, optimal dose allocation, defined as the ratio of low-energy ESD and the total ESD, varied from 0.2 to 0.4 over the range ESD=(0.05-5.0) mGy. Furthermore, two applications of the theoretical framework were explored: (i) the increase in detectability for DE imaging compared to conventional radiography; and (ii) the performance of single-shot vs double-shot DE imaging, wherein the latter is found to have a DQE approximately twice that of the former. Experimental and theoretical analysis of GNEQ and task-based detectability index provides a fundamental understanding of the factors governing DE imaging performance and offers a framework for system design and optimization.

Mesh:

Year:  2007        PMID: 17278498     DOI: 10.1118/1.2400620

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  20 in total

1.  Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging.

Authors:  P Prakash; W Zbijewski; G J Gang; Y Ding; J W Stayman; J Yorkston; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  Anatomical background and generalized detectability in tomosynthesis and cone-beam CT.

Authors:  G J Gang; D J Tward; J Lee; J H Siewerdsen
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

3.  A Statistical Model for Rigid Image Registration Performance: The Influence of Soft-Tissue Deformation as a Confounding Noise Source.

Authors:  Michael D Ketcha; Tharindu De Silva; Runze Han; Ali Uneri; Sebastian Vogt; Gerhard Kleinszig; Jeffrey H Siewerdsen
Journal:  IEEE Trans Med Imaging       Date:  2019-03-27       Impact factor: 10.048

4.  Comparison of model and human observer performance for detection and discrimination tasks using dual-energy x-ray images.

Authors:  Samuel Richard; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

5.  Multiscale deformable registration for dual-energy x-ray imaging.

Authors:  G J Gang; C A Varon; H Kashani; S Richard; N S Paul; R Van Metter; J Yorkston; J H Siewerdsen
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

6.  Cascaded systems analysis of noise and detectability in dual-energy cone-beam CT.

Authors:  Grace J Gang; Wojciech Zbijewski; J Webster Stayman; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

7.  Noise aliasing and the 3D NEQ of flat-panel cone-beam CT: effect of 2D/3D apertures and sampling.

Authors:  Daniel J Tward; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

8.  The effect of amorphous selenium detector thickness on dual-energy digital breast imaging.

Authors:  Yue-Houng Hu; Wei Zhao
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

9.  Physics considerations in MV-CBCT multi-layer imager design.

Authors:  Yue-Houng Hu; Rony Fueglistaller; Marios Myronakis; Joerg Rottmann; Adam Wang; Daniel Shedlock; Daniel Morf; Paul Baturin; Pascal Huber; Josh Star-Lack; Ross Berbeco
Journal:  Phys Med Biol       Date:  2018-06-20       Impact factor: 3.609

10.  Dual-energy cone-beam CT with a flat-panel detector: effect of reconstruction algorithm on material classification.

Authors:  W Zbijewski; G J Gang; J Xu; A S Wang; J W Stayman; K Taguchi; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.