Magnetic resonance imaging of the eye usually includes T2-weighted images both for screening purposes and for characterization of melanoma. Conventional T2-weighted spin-echo (SE) imaging suffers both from long acquisition times and incomplete recovery of the vitreous' signal. A fast SE sequence was therefore compared prospectively with conventional sequences in 29 consecutive patients with lesions of the eye. Fast SE images delineated melanoma and other lesions of the eye from vitreous better than conventional T2-weighted images. Image quality and lesion conspicuity were improved on the fast sequence. Whereas melanoma appeared hypointense to vitreous on both types of images, subretinal effusion was hypointense on fast images and hyperintense on conventional T2-weighted images. Ghosting of the globe, which, however, did not decrease diagnostic value, was more pronounced on fast images. Conventional T2-weighted images may be replaced by fast SE images in MR studies of the eye with a gain in lesion conspicuity and significant time saving.

Entities:  

Mesh:

Year:  1996        PMID: 8972329     DOI: 10.1007/bf00240700

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  10 in total

1.  Intracerebral lesion contrast with spin-echo and fast spin-echo pulse sequences.

Authors:  A M Norbash; G H Glover; D R Enzmann
Journal:  Radiology       Date:  1992-12       Impact factor: 11.105

2.  Brain hemorrhage: evaluation with fast spin-echo and conventional dual spin-echo images.

Authors:  K M Jones; R V Mulkern; M T Mantello; P S Melki; S S Ahn; P D Barnes; F A Jolesz
Journal:  Radiology       Date:  1992-01       Impact factor: 11.105

3.  Measuring signal-to-noise ratios in MR imaging.

Authors:  L Kaufman; D M Kramer; L E Crooks; D A Ortendahl
Journal:  Radiology       Date:  1989-10       Impact factor: 11.105

4.  Diagnosis of mesial temporal sclerosis with conventional versus fast spin-echo MR imaging.

Authors:  C R Jack; K N Krecke; P H Luetmer; G D Cascino; F W Sharbrough; P C O'Brien; J E Parisi
Journal:  Radiology       Date:  1994-07       Impact factor: 11.105

5.  Choroidal hematoma and effusion: evaluation with MR imaging.

Authors:  M F Mafee; B Linder; G A Peyman; B G Langer; K H Choi; V Capek
Journal:  Radiology       Date:  1988-09       Impact factor: 11.105

6.  Clinical evaluation of fast spin echo sequences for cranial magnetic resonance imaging at 0.5 tesla.

Authors:  J M Hawnaur; C E Hutchinson; I Isherwood
Journal:  Br J Radiol       Date:  1994-05       Impact factor: 3.039

7.  Shortcomings and pitfalls of ocular MRI.

Authors:  G Wilms; G Marchal; L Van Fraeyenhoven; P Demaerel; P Van Hecke; A L Baert; G Dralands
Journal:  Neuroradiology       Date:  1991       Impact factor: 2.804

8.  Malignant uveal melanoma and simulating lesions: MR imaging evaluation.

Authors:  M F Mafee; G A Peyman; J E Grisolano; M E Fletcher; D G Spigos; F W Wehrli; F Rasouli; V Capek
Journal:  Radiology       Date:  1986-09       Impact factor: 11.105

9.  Magnetic resonance imaging in the evaluation and differentiation of uveal melanoma.

Authors:  M F Mafee; G A Peyman; J H Peace; S B Cohen; M W Mitchell
Journal:  Ophthalmology       Date:  1987-04       Impact factor: 12.079

10.  Fast spin-echo imaging in the evaluation of intradural disease of the spine.

Authors:  G Sze; M Merriam; K Oshio; F A Jolesz
Journal:  AJNR Am J Neuroradiol       Date:  1992 Sep-Oct       Impact factor: 3.825

  10 in total
  4 in total

Review 1.  Imaging of orbital disorders in pediatric patients.

Authors:  Luis Gorospe; Aránzazu Royo; Teresa Berrocal; Pilar García-Raya; Pilar Moreno; José Abelairas
Journal:  Eur Radiol       Date:  2002-11-19       Impact factor: 5.315

2.  High resolution magnetic resonance imaging of retinoblastoma.

Authors:  A O Schueler; N Hosten; N E Bechrakis; A J Lemke; P Foerster; R Felix; M H Foerster; N Bornfeld
Journal:  Br J Ophthalmol       Date:  2003-03       Impact factor: 4.638

Review 3.  Imaging of Uveal Melanoma-Current Standard and Methods in Development.

Authors:  Małgorzata Solnik; Natalia Paduszyńska; Anna M Czarnecka; Kamil J Synoradzki; Yacoub A Yousef; Tomasz Chorągiewicz; Robert Rejdak; Mario Damiano Toro; Sandrine Zweifel; Katarzyna Dyndor; Michał Fiedorowicz
Journal:  Cancers (Basel)       Date:  2022-06-27       Impact factor: 6.575

Review 4.  Imaging systems of human eye: a review.

Authors:  Rajendra U Acharya; Wong Li Yun; E Y K Ng; Wenwei Yu; Jasjit S Suri
Journal:  J Med Syst       Date:  2008-08       Impact factor: 4.460