Literature DB >> 17268867

Staphylococcus aureus adhesion to standard micro-rough and electropolished implant materials.

Llinos G Harris1, D Osian Meredith, Lukas Eschbach, R Geoff Richards.   

Abstract

Implant-associated infections can cause serious complications including osteomyelitis and soft tissue damage, and are a great problem due to the emergence of antibiotic resistant bacteria such as methicillin-resistant Staphylococcus aureus (MRSA). In some cases, antibiotic-loaded beads which release the antibiotic locally have been used, however such systems may lead to the development of antibiotic-resistant bacteria, as seen with gentamicin-loaded beads. Hence modifying the actual metal implant surface to inhibit or reduce initial bacterial adhesion may be an alternative option. This study describes the visualisation and quantification of S. aureus adhering to standard micro-rough 'commercially pure' titanium (TS) and Ti-6Al-7Nb (NS) surfaces, electropolished titanium (TE) and Ti-6Al-7Nb (NE) surfaces, and standard electropolished stainless steel (SS). Qualitative and quantitative results of S. aureus on the different surfaces correlated with each other, and showed significantly more live bacteria on NS than on the other surfaces, whilst there was no significant difference between the amount of bacteria on TS, TE, NE and SS surfaces. The results showed a significant decrease in the amount of bacteria adhering to the NE compared to standard NS surfaces. Such an observation suggests that the NS surface encouraged S. aureus adhesion, and could lead to higher infection rates in vivo. Hence electropolishing Ti-6Al-7Nb surfaces could be advantageous in osteosynthesis areas in minimising bacterial adhesion and lowering the rate of infection.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17268867     DOI: 10.1007/s10856-007-0143-0

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   4.727


  28 in total

1.  Infection after intramedullary nailing of the tibia. Incidence and protocol for management.

Authors:  C M Court-Brown; J F Keating; M M McQueen
Journal:  J Bone Joint Surg Br       Date:  1992-09

Review 2.  Staphylococcus aureus infections.

Authors:  F D Lowy
Journal:  N Engl J Med       Date:  1998-08-20       Impact factor: 91.245

3.  Preventing bacterial adhesion onto surfaces: the low-surface-energy approach.

Authors:  J Tsibouklis; M Stone; A A Thorpe; P Graham; V Peters; R Heerlien; J R Smith; K L Green; T G Nevell
Journal:  Biomaterials       Date:  1999-07       Impact factor: 12.479

4.  Adhesive colonization of biomaterials and antibiotic resistance.

Authors:  A G Gristina; C D Hobgood; L X Webb; Q N Myrvik
Journal:  Biomaterials       Date:  1987-11       Impact factor: 12.479

Review 5.  The influence of surface roughness and surface-free energy on supra- and subgingival plaque formation in man. A review of the literature.

Authors:  M Quirynen; C M Bollen
Journal:  J Clin Periodontol       Date:  1995-01       Impact factor: 8.728

6.  Physical and biological effects of a surface coating procedure on polyurethane catheters.

Authors:  P Francois; P Vaudaux; N Nurdin; H J Mathieu; P Descouts; D P Lew
Journal:  Biomaterials       Date:  1996-04       Impact factor: 12.479

7.  Surface characterization of implant materials c.p. Ti, Ti-6Al-7Nb and Ti-6Al-4V with different pretreatments.

Authors:  C Sittig; M Textor; N D Spencer; M Wieland; P H Vallotton
Journal:  J Mater Sci Mater Med       Date:  1999-01       Impact factor: 3.896

8.  Gentamicin coating of metallic implants reduces implant-related osteomyelitis in rats.

Authors:  M Lucke; G Schmidmaier; S Sadoni; B Wildemann; R Schiller; N P Haas; M Raschke
Journal:  Bone       Date:  2003-05       Impact factor: 4.398

9.  Staphylococcus aureus adhesion to titanium oxide surfaces coated with non-functionalized and peptide-functionalized poly(L-lysine)-grafted-poly(ethylene glycol) copolymers.

Authors:  L G Harris; S Tosatti; M Wieland; M Textor; R G Richards
Journal:  Biomaterials       Date:  2004-08       Impact factor: 12.479

10.  Adherence to a metal, polymer and composite by Staphylococcus aureus and Staphylococcus epidermidis.

Authors:  C C Verheyen; W J Dhert; J M de Blieck-Hogervorst; T J van der Reijden; P L Petit; K de Groot
Journal:  Biomaterials       Date:  1993-04       Impact factor: 12.479

View more
  21 in total

Review 1.  Nanostructured platforms for the sustained and local delivery of antibiotics in the treatment of osteomyelitis.

Authors:  Vuk Uskokovic
Journal:  Crit Rev Ther Drug Carrier Syst       Date:  2015       Impact factor: 4.889

Review 2.  [Susceptibility to infections and behavior of stainless steel : Comparison with titanium implants in traumatology].

Authors:  Patrick Haubruck; Gerhard Schmidmaier
Journal:  Unfallchirurg       Date:  2017-02       Impact factor: 1.000

3.  Bacterial adhesion characteristics on implant materials for intervertebral cages: titanium or PEEK for spinal infections?

Authors:  Samira Weisselberg; Sven Oliver Eicker; Theresa Krätzig; Klaus Christian Mende; Malte Mohme; Simon von Kroge; Martin Stangenberg; Marc Dreimann; Manfred Westphal
Journal:  Eur Spine J       Date:  2021-01-09       Impact factor: 3.134

Review 4.  Mechano-bactericidal actions of nanostructured surfaces.

Authors:  Denver P Linklater; Vladimir A Baulin; Saulius Juodkazis; Russell J Crawford; Paul Stoodley; Elena P Ivanova
Journal:  Nat Rev Microbiol       Date:  2020-08-17       Impact factor: 60.633

5.  Infection in fracture fixation: can we influence infection rates through implant design?

Authors:  T Fintan Moriarty; U Schlegel; S Perren; R Geoff Richards
Journal:  J Mater Sci Mater Med       Date:  2009-10-20       Impact factor: 3.896

6.  Osteosarcoma of the proximal tibia in a dog 6 years after tibial tuberosity advancement.

Authors:  Surabhi Sharma; Sarah E Boston; Douglas Riddle; Kevin Isakow
Journal:  Can Vet J       Date:  2020-09       Impact factor: 1.008

7.  The influence of maggot excretions on PAO1 biofilm formation on different biomaterials.

Authors:  Gwendolyn Cazander; Kiril E B van Veen; Lee H Bouwman; Alexandra T Bernards; Gerrolt N Jukema
Journal:  Clin Orthop Relat Res       Date:  2008-10-16       Impact factor: 4.176

8.  Material and biofilm load of K wires in toe surgery: titanium versus stainless steel.

Authors:  Martin Clauss; Susanne Graf; Silke Gersbach; Beat Hintermann; Thomas Ilchmann; Markus Knupp
Journal:  Clin Orthop Relat Res       Date:  2013-03-16       Impact factor: 4.176

9.  Staphylococcal biofilm formation on the surface of three different calcium phosphate bone grafts: a qualitative and quantitative in vivo analysis.

Authors:  Ulrika Furustrand Tafin; Bertrand Betrisey; Marc Bohner; Thomas Ilchmann; Andrej Trampuz; Martin Clauss
Journal:  J Mater Sci Mater Med       Date:  2015-02-19       Impact factor: 3.896

10.  Dormant cells of Staphylococcus aureus are resuscitated by spent culture supernatant.

Authors:  Ben Pascoe; Lucy Dams; Tom S Wilkinson; Llinos G Harris; Owen Bodger; Dietrich Mack; Angharad P Davies
Journal:  PLoS One       Date:  2014-02-11       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.