Literature DB >> 12753868

Gentamicin coating of metallic implants reduces implant-related osteomyelitis in rats.

M Lucke1, G Schmidmaier, S Sadoni, B Wildemann, R Schiller, N P Haas, M Raschke.   

Abstract

Antibiotic prophylaxis is a routine procedure in orthopedic surgery. Various local antibiotic delivery techniques are used to reduce bone- and soft tissue-related infection. The objective of this study was to evaluate the efficacy of a new biodegradable, gentamicin-loaded poly(D,L-lactide) (PDLLA) coating of orthopedic devices in preventing implant-related osteomyelitis. The medullary cavities of tibiae in 30 Sprague Dawley rats were contaminated with Staphylococcus aureus (10(3) colony forming units). Simultaneously titanium Kirschner wires, uncoated (group II), coated with PDLLA (group III), or coated with PDLLA + 10% gentamicin (group IV), were implanted. Ten animals that received phosphate-buffered saline and uncoated Kirschner wires served as controls (group I). Follow-up was 6 weeks. In weekly intervals X-rays of the tibiae were performed, blood counts were taken, and body temperature and weight were determined. After sacrifice infection was evaluated by histological and microbiological analysis. All animals of groups II and III developed microbiological, histological, and radiological signs of infection, including osseous destruction and soft tissue swelling. All animals of the control group remained sterile. Cultures of implants of group IV showed significantly reduced bacterial growth compared to cultures of groups II and III, and three implants of group IV remained sterile. Further radiological and histological signs of infection were significantly reduced in the gentamicin-coated group compared to groups II and III. No significant differences in body weight, body temperature, and blood parameters between all groups were observed. Local application of antibiotic-coated orthopedic devices containing PDLLA and 10% gentamicin significantly reduced implant-related infection in this animal model.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12753868     DOI: 10.1016/s8756-3282(03)00050-4

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  62 in total

Review 1.  Nanoscale surface modifications of medically relevant metals: state-of-the art and perspectives.

Authors:  Fabio Variola; John B Brunski; Giovanna Orsini; Paulo Tambasco de Oliveira; Rima Wazen; Antonio Nanci
Journal:  Nanoscale       Date:  2010-10-26       Impact factor: 7.790

2.  An asymmetric coating composed of gelatin and hydroxyapatite for the delivery of water insoluble drug.

Authors:  Junwu Xiao; Yingchun Zhu; Yanyan Liu; Yi Zeng; Fangfang Xu
Journal:  J Mater Sci Mater Med       Date:  2008-11-20       Impact factor: 3.896

3.  Did local teicoplanin delivery systems inhibit or aggravate implant-related infection?

Authors:  Xun-Zi Cai; Ai-Dong Jin; Shi-Gui Yan
Journal:  Int Orthop       Date:  2009-06-18       Impact factor: 3.075

4.  Aminoglycoside-resistant staphylococci in Greece: prevalence and resistance mechanisms.

Authors:  A Liakopoulos; A Foka; S Vourli; L Zerva; F Tsiapara; E Protonotariou; Z Dailiana; M Economou; E Papoutsidou; C Koutsia-Carouzou; E D Anastassiou; E Diza; E Zintzaras; I Spiliopoulou; E Petinaki
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-01-09       Impact factor: 3.267

Review 5.  Infected animal models for tissue engineering.

Authors:  Alexander M Tatara; Sarita R Shah; Carissa E Livingston; Antonios G Mikos
Journal:  Methods       Date:  2015-04-02       Impact factor: 3.608

Review 6.  [Susceptibility to infections and behavior of stainless steel : Comparison with titanium implants in traumatology].

Authors:  Patrick Haubruck; Gerhard Schmidmaier
Journal:  Unfallchirurg       Date:  2017-02       Impact factor: 1.000

7.  The effects of farnesol on Staphylococcus aureus biofilms and osteoblasts. An in vitro study.

Authors:  Aasis Unnanuntana; Lindsay Bonsignore; Mark E Shirtliff; Edward M Greenfield
Journal:  J Bone Joint Surg Am       Date:  2009-11       Impact factor: 5.284

8.  The effectiveness of the controlled release of gentamicin from polyelectrolyte multilayers in the treatment of Staphylococcus aureus infection in a rabbit bone model.

Authors:  Joshua S Moskowitz; Michael R Blaisse; Raymond E Samuel; Hu-Ping Hsu; Mitchel B Harris; Scott D Martin; Jean C Lee; Myron Spector; Paula T Hammond
Journal:  Biomaterials       Date:  2010-05-21       Impact factor: 12.479

Review 9.  Therapeutics and delivery vehicles for local treatment of osteomyelitis.

Authors:  Leah H Cobb; Emily M McCabe; Lauren B Priddy
Journal:  J Orthop Res       Date:  2020-04-21       Impact factor: 3.494

10.  A mouse model of post-arthroplasty Staphylococcus aureus joint infection to evaluate in vivo the efficacy of antimicrobial implant coatings.

Authors:  Nicholas M Bernthal; Alexandra I Stavrakis; Fabrizio Billi; John S Cho; Thomas J Kremen; Scott I Simon; Ambrose L Cheung; Gerald A Finerman; Jay R Lieberman; John S Adams; Lloyd S Miller
Journal:  PLoS One       Date:  2010-09-07       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.