Literature DB >> 1723197

Radiation-induced effects in multiprogrammable pacemakers and implantable defibrillators.

F Rodriguez1, A Filimonov, A Henning, C Coughlin, M Greenberg.   

Abstract

Twenty-three multiprogrammable pacemakers and four implantable cardioverter defibrillators (ICDs) containing either complementary metal-oxide semiconductor (CMOS) or CMOS/Bipolar integrated circuit (IC) technology were exposed to 6-MV photon and 18-MeV electron radiation at various dose levels. Of the 17 pacemakers exposed to photon radiation eight failed before 50 Gy, whereas four of the six pacemakers exposed to electron radiation failed before 70 Gy. Photon scatter doses were well tolerated. For the ICDs detection and charging time increased with accumulated radiation dose, the charging time increased catastrophically at less than 50 total pulses delivered when compared with the charging time of six implanted ICDs. Sensitivity and output energy delivered by the ICD pulse were constant during the test. It was found that devices using the shorter channel length IC technology (i.e., 3 microns CMOS) were per se harder to ionizing radiation than the devices using larger channel length IC technologies (i.e., either 8 microns CMOS or combined 5 microM CMOS/20 V Bipolar). In fact, none of the devices based on 3 microns CMOS IC technology failed before 76 Gy, which is above the highest dose level (70 Gy) normally used in radiation oncology treatments.

Entities:  

Mesh:

Year:  1991        PMID: 1723197     DOI: 10.1111/j.1540-8159.1991.tb06485.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  14 in total

1.  Radiation tolerance of contemporary implantable cardioverter-defibrillators.

Authors:  Michael Mollerus; Leslee Naslund; Margaret Lipinski; Anne Meyer; Bruce Libey; Ken Dornfeld
Journal:  J Interv Card Electrophysiol       Date:  2013-12-07       Impact factor: 1.900

Review 2.  Arrhythmias and Other Electrophysiology Issues in Cancer Patients Receiving Chemotherapy or Radiation.

Authors:  Federico Viganego; Robin Singh; Michael G Fradley
Journal:  Curr Cardiol Rep       Date:  2016-06       Impact factor: 2.931

3.  Experimental study of neutron-induced soft errors in modern cardiac pacemakers.

Authors:  Alexandre Trigano; Guillaume Hubert; Jannie Marfaing; Karine Castellani
Journal:  J Interv Card Electrophysiol       Date:  2011-08-24       Impact factor: 1.900

4.  Effect of X-ray dose rates higher than 8 Gy/min on the functioning of cardiac implantable electronic devices.

Authors:  Kazuhiko Nakamura; Takahiro Aoyama; Naoki Kaneda; Masashi Otsuji; Yoshitaka Minami; Ami Sakuragi; Masaru Nakamura
Journal:  J Radiat Res       Date:  2020-05-22       Impact factor: 2.724

5.  Interference detection in implantable defibrillators induced by therapeutic radiation therapy.

Authors:  G J Uiterwaal; B G F Springorum; E Scheepers; G S de Ruiter; C W Hurkmans
Journal:  Neth Heart J       Date:  2006-10       Impact factor: 2.380

6.  Electromagnetic interference in patients with implanted cardioverter-defibrillators and implantable loop recorders.

Authors:  Marcos de Sousa; Gunnar Klein; Thomas Korte; Michael Niehaus
Journal:  Indian Pacing Electrophysiol J       Date:  2002-07-01

7.  Effects of external electrical and magnetic fields on pacemakers and defibrillators: from engineering principles to clinical practice.

Authors:  Roy Beinart; Saman Nazarian
Journal:  Circulation       Date:  2013-12-24       Impact factor: 29.690

8.  PAIDEIA: pacemaker and implanted cardioverter defibrillator management in radiation therapy-a survey by the Young Group of the Italian Association of Radiotherapy and Clinical Oncology (AIRO).

Authors:  Anna Rita Alitto; Silvia Chiesa; Pierfrancesco Franco; Michele Fiore; Lorenza Marino; Paolo Borghetti; Isacco Desideri; Daniela Greto; Alba Fiorentino
Journal:  Radiol Med       Date:  2019-12-12       Impact factor: 3.469

9.  Influence of secondary neutrons induced by proton radiotherapy for cancer patients with implantable cardioverter defibrillators.

Authors:  Takayuki Hashimoto; Tomonori Isobe; Haruko Hashii; Hiroaki Kumada; Hiroshi Tada; Toshiyuki Okumura; Koji Tsuboi; Takeji Sakae; Kazutaka Aonuma; Hideyuki Sakurai
Journal:  Radiat Oncol       Date:  2012-01-29       Impact factor: 3.481

10.  Management of radiation oncology patients with a pacemaker or ICD: a new comprehensive practical guideline in The Netherlands. Dutch Society of Radiotherapy and Oncology (NVRO).

Authors:  Coen W Hurkmans; Joost L Knegjens; Bing S Oei; Ad J J Maas; G J Uiterwaal; Arnoud J van der Borden; Marleen M J Ploegmakers; Lieselot van Erven
Journal:  Radiat Oncol       Date:  2012-11-24       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.