Pulsed electron avalanche knife: new technology for cataract surgery.

Siegfried G Priglinger1, Daniel Palanker, Claudia S Alge, Thomas C Kreutzer, Christos Haritoglou, Martin Grueterich, Anselm Kampik.   

Abstract

BACKGROUND: The pulsed electron avalanche knife (PEAK-fc) is a new pulsed electrosurgical device that allows for precise, "cold" and traction-free tissue dissection. AIM: To evaluate the surgical applicability, safety and potential complications of PEAK-fc in complicated cataract surgery.
METHODS: The study included five children with congenital cataracts, two patients with advanced senile cataracts, six adults with mature cataracts, three of them with posterior iris synechia, three patients with post-traumatic cataracts with zonulolysis, one patient with intumescent traumatic cataract and three patients with massive anterior capsule opacification. Anterior and posterior capsulotomies, iris synechiolysis, dissection of anterior capsule opacification and fibrotic scar tissue were performed. PEAK-fc was set at voltages of 500-700 V, pulse duration of 0.1 m and repetition rate of 40-100 Hz.
RESULTS: Anterior and posterior capsulotomies were successfully and safely performed in all eyes. The edges of capsulotomies appeared sharp, showing only limited collateral damage. PEAK-fc worked best by just gently touching the capsule, thereby avoiding tractional forces or pressure on the lens capsule. Posterior iris synechiae could be released and anterior capsule opacification was dissected without complications.
CONCLUSIONS: PEAK-fc is a very helpful cutting device for complicated cases of cataract surgery, especially for mature and congenital cataracts, traumatic zonulolysis or anterior segment complications after intraocular inflammation.

Entities:  

Mesh:

Year:  2007        PMID: 17229798      PMCID: PMC1955651          DOI: 10.1136/bjo.2006.109546

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  17 in total

1.  Endothelial cell loss after phacoemulsification: relation to preoperative and intraoperative parameters.

Authors:  T Walkow; N Anders; S Klebe
Journal:  J Cataract Refract Surg       Date:  2000-05       Impact factor: 3.351

2.  Effects of the pulsed electron avalanche knife on retinal tissue.

Authors:  Daniel V Palanker; Michael F Marmor; Andre Branco; Philip Huie; Jason M Miller; Steven R Sanislo; Alexander Vankov; Mark S Blumenkranz
Journal:  Arch Ophthalmol       Date:  2002-05

3.  [Anterior high frequency capsulotomy. I. Experimental study].

Authors:  R Klöti
Journal:  Klin Monbl Augenheilkd       Date:  1992-05       Impact factor: 0.700

4.  Precision and safety of the pulsed electron avalanche knife in vitreoretinal surgery.

Authors:  Jason M Miller; Daniel V Palanker; Alexander Vankov; Michael F Marmor; Mark S Blumenkranz
Journal:  Arch Ophthalmol       Date:  2003-06

5.  In situ fracture.

Authors:  J R Shepherd
Journal:  J Cataract Refract Surg       Date:  1990-07       Impact factor: 3.351

6.  Diathermic capsulotomy versus capsulorhexis: a biomechanical study.

Authors:  S Krag; K Thim; L Corydon
Journal:  J Cataract Refract Surg       Date:  1997 Jan-Feb       Impact factor: 3.351

7.  [Theory and surgical technic of capsulorhexis].

Authors:  T Neuhann
Journal:  Klin Monbl Augenheilkd       Date:  1987-06       Impact factor: 0.700

8.  Pulsed electron avalanche knife (PEAK-fc) for dissection of retinal tissue.

Authors:  Siegfried G Priglinger; Christos Haritoglou; Daniel V Palanker; Claudia S Alge; Arnd Gandorfer; Anselm Kampik
Journal:  Arch Ophthalmol       Date:  2005-10

9.  Effect of cataract surgery on the corneal endothelium: modern phacoemulsification compared with extracapsular cataract surgery.

Authors:  Rupert R A Bourne; Darwin C Minassian; John K G Dart; Paul Rosen; Sundeep Kaushal; Nicholas Wingate
Journal:  Ophthalmology       Date:  2004-04       Impact factor: 12.079

10.  Comparison of mechanized anterior capsulectomy and manual continuous capsulorhexis in pediatric eyes.

Authors:  M E Wilson; E C Bluestein; X H Wang; D J Apple
Journal:  J Cataract Refract Surg       Date:  1994-11       Impact factor: 3.351

View more
  7 in total

1.  Comparative analysis on the effect of low-thermal plasma dissection device (PEAK PlasmaBlade) versus conventional electro surgery in post-bariatric body-contouring procedures: A retrospective randomised clinical study.

Authors:  Torsten Schlosshauer; Marcus Kiehlmann; Pablo Ramirez; Marc-Oliver Riener; Gabriel Djedovic; Ulrich M Rieger
Journal:  Int Wound J       Date:  2019-04-01       Impact factor: 3.315

2.  Anterior capsulotomy with a pulsed-electron avalanche knife.

Authors:  Daniel Palanker; Hiroyuki Nomoto; Philip Huie; Alexander Vankov; David F Chang
Journal:  J Cataract Refract Surg       Date:  2010-01       Impact factor: 3.351

3.  Automated microscopy to evaluate surgical specimens via touch prep in breast cancer.

Authors:  Maria Jose Cortes-Mateos; David Martin; Sergio Sandoval; Manuel E Ruidiaz; Davorka Messmer; Jessica Wang-Rodriguez; William Trogler; Andrew C Kummel; Sarah L Blair
Journal:  Ann Surg Oncol       Date:  2009-01-10       Impact factor: 5.344

4.  Visual and optical performance of diffractive multifocal intraocular lenses with different haptic designs: 6 month follow-up.

Authors:  Mengmeng Wang; Christine Carole C Corpuz; Megumi Fujiwara; Minoru Tomita
Journal:  Clin Ophthalmol       Date:  2014-05-14

5.  Targeted In Situ Biosynthetic Transcriptional Activation in Native Surface-Level Human Articular Chondrocytes during Lesion Stabilization.

Authors:  Kumkum Ganguly; Ian D McRury; Peter M Goodwin; Roy E Morgan; Wayne K Augé
Journal:  Cartilage       Date:  2012-04       Impact factor: 4.634

6.  Lens decompression technique for prevention of intraoperative complications during phacoemulsification of intumescent cataract.

Authors:  Karim Mahmoud Nabil
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

7.  Comparative healing of swine skin following incisions with different surgical devices.

Authors:  Yuting Zhong; Yufan Wei; Ningning Min; Qingyu Guan; Jin Zhao; Junyong Zhu; Huayu Hu; Rui Geng; Chenyan Hong; Yashuang Ji; Jie Li; Yiqiong Zheng; Yanjun Zhang; Xiru Li
Journal:  Ann Transl Med       Date:  2021-10
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.