Literature DB >> 17224751

Noninvasive determination of intraocular pressure (IOP) in nonsedated mice of 5 different inbred strains.

Nicholas Nissirios1, David Goldblum, Kaspar Rohrer, Thomas Mittag, John Danias.   

Abstract

BACKGROUND: Noninvasive intraocular pressure (IOP) measurement in mice is critically important for understanding the pathophysiology of glaucoma. Rebound tonometry is one of the methods that can be used for obtaining such measurements. We evaluated the ability of the rebound tonometer (RT) to determine IOP differences among various mouse strains and whether differences in corneal thickness may affect IOP measurements in these animals.
MATERIALS AND METHODS: Five different commonly used mouse strains (BALB/C, CBA/CAHN, AKR/J, CBA/J, and 129P3/J) were used. IOP was measured in eyes from 12 nonsedated animals (6 male and 6 female) from each strain at 2 to 3 months of age using the RT. IOPs were measured in all animals, on 2 different days between 10 AM and 12 PM. Subsequently, a number of eyes from each strain were cannulated to provide a calibration curve specific for that strain. Tonometer readings for all strains were converted to apparent IOP values using the calibration data obtained from the calibration curve of the respective strain. For comparison purposes, IOP values were also obtained using the C57BL/6 calibration data previously reported. IOP for the 5 strains, male and female animals, and the different occasion of measurement were compared using repeat measures analysis of variance. The central corneal thickness (CCT) of another group of 8 male animals from each of the 5 strains was also measured using an optical low coherence reflectometry (OLCR) pachymeter modified for use with mice. CCT values were correlated to mean IOPs of male animals and to the slopes and intercept of individual strain calibration curves.
RESULTS: Noninvasive IOP measurements confirm that the BALB/C strain has lower and the CBA/CAHN has higher relative IOPs than other mouse strains while the AKR/J, the CBA/J, and the 129P3/J strains have intermediate IOPs. There is a very good correlation of apparent IOP values obtained by RT with previously reported true IOPs obtained by cannulation. There was a small but statistically significant difference in IOP between male and female animals in 2 strains (129P3/J and AKR/J) with female mice having higher relative IOPs. No correlation between CCT and IOP was detected. CCT did not correlate with any of the constants describing the calibration curves in the various strains.
CONCLUSIONS: Noninvasive IOP measurement in mice using the RT can be used to help elucidate IOP phenotype, after prior calibration of the tonometer. CCT has no effect on mouse IOP measurements using the RT.

Entities:  

Mesh:

Year:  2007        PMID: 17224751     DOI: 10.1097/IJG.0b013e31802b3547

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  25 in total

1.  Calibration of the TonoLab tonometer in mice with spontaneous or experimental glaucoma.

Authors:  Mary E Pease; Frances E Cone; Scott Gelman; Janice L Son; Harry A Quigley
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-02-22       Impact factor: 4.799

2.  Retinal gene expression changes related to IOP exposure and axonal loss in DBA/2J mice.

Authors:  Lambros Panagis; Xiujun Zhao; Yongchao Ge; Lizhen Ren; Thomas W Mittag; John Danias
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-10-03       Impact factor: 4.799

3.  Effect of hevin deletion in mice and characterization in trabecular meshwork.

Authors:  Min Hyung Kang; Dong-Jin Oh; Douglas J Rhee
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-04-06       Impact factor: 4.799

4.  Reliability of Tonolab measurements in rats.

Authors:  Li-Fang Liu; Chu-Kai Huang; Ming-Zhi Zhang
Journal:  Int J Ophthalmol       Date:  2014-12-18       Impact factor: 1.779

5.  Topography and pachymetry maps for mouse corneas using optical coherence tomography.

Authors:  Alice S Liu; Dillon M Brown; Rachel E Conn; Ryan P McNabb; Machelle T Pardue; Anthony N Kuo
Journal:  Exp Eye Res       Date:  2019-11-05       Impact factor: 3.467

6.  Central corneal thickness does not correlate with TonoLab-measured IOP in several mouse strains with single transgenic mutations of matricellular proteins.

Authors:  Ayan Chatterjee; Dong-Jin Oh; Min Hyung Kang; Douglas J Rhee
Journal:  Exp Eye Res       Date:  2013-06-24       Impact factor: 3.467

7.  Transgenic mice expressing mutated Tyr437His human myocilin develop progressive loss of retinal ganglion cell electrical responsiveness and axonopathy with normal iop.

Authors:  Tsung-Han Chou; Stanislav Tomarev; Vittorio Porciatti
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-08-14       Impact factor: 4.799

8.  Efficient in vivo doxycycline and cre recombinase-mediated inducible transgene activation in the murine trabecular meshwork.

Authors:  Pu Liu; Xueyao Fu; Randy L Johnson
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-02-23       Impact factor: 4.799

9.  Triamcinolone acetonide decreases outflow facility in C57BL/6 mouse eyes.

Authors:  Sandeep Kumar; Shaily Shah; Emily Rose Deutsch; Hai Michael Tang; John Danias
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-02-01       Impact factor: 4.799

10.  The influence of genetic background on conventional outflow facility in mice.

Authors:  Alexandra Boussommier-Calleja; Darryl R Overby
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-12-19       Impact factor: 4.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.