Diurnal variation of central corneal thickness and Goldmann applanation tonometry estimates of intraocular pressure.

Kirsten Elizabeth Hamilton1, David Cecil Pye, Shivani Aggarwala, Sindy Evian, Joti Khosla, Rachithri Perera.   

Abstract

PURPOSE: To determine whether there is a temporal relationship between the diurnal variation of central corneal thickness (CCT) and intraocular pressure (IOP) by Goldmann applanation tonometry in young normal human participants in vivo.
METHODS: Twenty-five eyes of 25 young healthy normal participants were examined in a prospective observational cross-sectional study. IOP, CCT and corneal curvature were measured using standard clinical techniques over a 24-hour period, and the temporal interrelationships between these parameters were examined.
RESULTS: The overnight change in IOP measured by Goldmann tonometry was 3.1+/-2.4 mm Hg (P<0.001), CCT was 20.1+/-10.9 mum (P=0.016), with no statistical change in central corneal curvature (0.05 mm, P=0.477, paired t test with Bonferroni correction). Both IOP and CCT were highest on awakening at 7:00 then dropped rapidly to baseline levels by 9:00 (linear mixed models), and these two parameters were highly correlated (r=0.978, P<0.001). After 9:00, there was no correlation between these parameters (r=-0.453, P=0.260).
CONCLUSIONS: The results of this study have highlighted a potential link between the diurnal variation of CCT and the accuracy of Goldmann tonometry estimates of IOP during the first 2 hours after awakening. Clinicians should be wary of using Goldmann tonometry to estimate IOP until the overnight increase in CCT has resolved.

Entities:  

Mesh:

Year:  2007        PMID: 17224746     DOI: 10.1097/IJG.0b013e31802b350f

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  8 in total

1.  Diurnal variations of central corneal thickness and intraocular pressure in dogs from 8:00 am to 8:00 pm.

Authors:  Eva Martín-Suárez; Carolina Molleda; Rodrigo Tardón; Alba Galán; José Gallardo; José Molleda
Journal:  Can Vet J       Date:  2014-04       Impact factor: 1.008

2.  Clinical evaluation of multiparameter correction equations for Goldmann applanation tonometry.

Authors:  P G Davey; A Elsheikh; D F Garway-Heath
Journal:  Eye (Lond)       Date:  2013-03-15       Impact factor: 3.775

3.  Reproducibility of Central Corneal Thickness Measurements in Healthy and Glaucomatous Eyes.

Authors:  Tony Realini; Matthew J Gurka; Robert N Weinreb
Journal:  J Glaucoma       Date:  2017-09       Impact factor: 2.503

4.  Time course of conjunctival hyperemia induced by omidenepag isopropyl ophthalmic solution 0.002%: a pilot, comparative study versus ripasudil 0.4.

Authors:  Etsuko Terao; Shunsuke Nakakura; Yasuko Fujisawa; Yuki Nagata; Kanae Ueda; Yui Kobayashi; Satomi Oogi; Saki Dote; Miku Shiraishi; Hitoshi Tabuchi; Tsuyoshi Yoneda; Atsuki Fukushima; Ryo Asaoka; Yoshiaki Kiuchi
Journal:  BMJ Open Ophthalmol       Date:  2020-08-02

5.  The effect of contact lens induced oedema on the accuracy of Goldmann tonometry in a mature population.

Authors:  K Hamilton; D Pye; S Hua; F Yu; J Chung; Q Hou
Journal:  Br J Ophthalmol       Date:  2007-05-15       Impact factor: 4.638

6.  Analysis of differences in intraocular pressure evaluation performed with contact and non-contact devices.

Authors:  Michele Lanza; Michele Rinaldi; Ugo Antonello Gironi Carnevale; Silvio di Staso; Mario Bifani Sconocchia; Ciro Costagliola
Journal:  BMC Ophthalmol       Date:  2018-09-03       Impact factor: 2.209

7.  Diurnal Variations in Intraocular Pressure, Central Corneal Thickness, and Macular and Retinal Nerve Fiber Layer Thickness in Diabetics and Normal Individuals.

Authors:  Farideh Sharifipour; Fereidoun Farrahi; Alireza Moghaddasi; Aida Idani; Mehdi Yaseri
Journal:  J Ophthalmic Vis Res       Date:  2016 Jan-Mar

8.  High intercorneal symmetry in corneal biomechanical metrics.

Authors:  XiaoBo Zheng; FangJun Bao; Brendan Geraghty; JinHai Huang; Ayong Yu; QinMei Wang
Journal:  Eye Vis (Lond)       Date:  2016-03-05
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.