Literature DB >> 17197535

The effects of study design and spectrum bias on the evaluation of diagnostic accuracy of confocal scanning laser ophthalmoscopy in glaucoma.

Felipe A Medeiros1, Diana Ng, Linda M Zangwill, Pamela A Sample, Christopher Bowd, Robert N Weinreb.   

Abstract

PURPOSE: To assess the effects of study design and spectrum bias on the evaluation of diagnostic accuracy of confocal scanning laser ophthalmoscopy (CSLO) in glaucoma.
METHODS: Analysis 1 included 67 eyes with glaucomatous visual field loss and 56 eyes of normal volunteers. Estimates of diagnostic accuracy in this analysis were compared to those obtained from analysis 2, which included a cohort of patients with suspected glaucoma, but without visual field loss at the time of CSLO imaging. For analysis 2, 40 eyes with progressive glaucomatous optic disc change were included in the glaucoma group and 43 eyes without any evidence of progressive damage to the optic nerve that were observed untreated for an average time of 9.01 +/- 3.09 years were included in the normal group. Areas under the receiver operating characteristic (ROC) curves (AUC) were used to evaluate diagnostic accuracy of CSLO parameters.
RESULTS: There was a statistically significant difference between the performance of the parameter with largest AUC, discriminant function Bathija, in analysis 1 (AUC = 0.91) compared with its performance in analysis 2 (AUC = 0.71; P = 0.002). For the contour-line-independent parameter glaucoma probability score, a statistically significant difference was also observed in the performance obtained in analysis 1 (AUC = 0.89) compared with analysis 2 (AUC = 0.65; P < 0.001).
CONCLUSIONS: Estimates of diagnostic accuracy of CSLO in glaucoma can be largely different depending on the population studied and the reference standard used to define disease. Diagnostic accuracy estimates obtained from case-control studies including well-defined groups of subjects with or without disease may not be applicable to the clinically relevant population.

Entities:  

Mesh:

Year:  2007        PMID: 17197535     DOI: 10.1167/iovs.06-0618

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  29 in total

1.  Retinal nerve fiber layer and macular inner retina measurements by spectral domain optical coherence tomograph in Indian eyes with early glaucoma.

Authors:  H L Rao; J G Babu; U K Addepalli; S Senthil; C S Garudadri
Journal:  Eye (Lond)       Date:  2011-11-11       Impact factor: 3.775

2.  Comparison of different spectral domain OCT scanning protocols for diagnosing preperimetric glaucoma.

Authors:  Renato Lisboa; Augusto Paranhos; Robert N Weinreb; Linda M Zangwill; Mauro T Leite; Felipe A Medeiros
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-05-13       Impact factor: 4.799

3.  A Comparison of OCT Parameters in Identifying Glaucoma Damage in Eyes Suspected of Having Glaucoma.

Authors:  Brian C Stagg; Felipe A Medeiros
Journal:  Ophthalmol Glaucoma       Date:  2019-11-27

4.  Retinal nerve fiber layer evaluation of spectral domain optical coherence tomograph and scanning laser polarimeter to diagnose glaucoma.

Authors:  H L Rao; R K Yadav; U K Addepalli; S Chaudhary; S Senthil; N S Choudhari; C S Garudadri
Journal:  Eye (Lond)       Date:  2014-03-07       Impact factor: 3.775

5.  Effect of disease severity and optic disc size on diagnostic accuracy of RTVue spectral domain optical coherence tomograph in glaucoma.

Authors:  Harsha L Rao; Mauro T Leite; Robert N Weinreb; Linda M Zangwill; Luciana M Alencar; Pamela A Sample; Felipe A Medeiros
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-03-10       Impact factor: 4.799

6.  Comparison of the diagnostic accuracies of the Spectralis, Cirrus, and RTVue optical coherence tomography devices in glaucoma.

Authors:  Mauro T Leite; Harsha L Rao; Linda M Zangwill; Robert N Weinreb; Felipe A Medeiros
Journal:  Ophthalmology       Date:  2011-03-05       Impact factor: 12.079

Review 7.  Ethnicity and ocular imaging.

Authors:  R R A Bourne
Journal:  Eye (Lond)       Date:  2010-12-17       Impact factor: 3.775

8.  Linear discriminant analysis and artificial neural network for glaucoma diagnosis using scanning laser polarimetry-variable cornea compensation measurements in Taiwan Chinese population.

Authors:  Mei-Ling Huang; Hsin-Yi Chen; Wei-Cheng Huang; Yi-Yu Tsai
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-12-15       Impact factor: 3.117

9.  Comparison of retinal nerve fiber layer and optic disc imaging for diagnosing glaucoma in patients suspected of having the disease.

Authors:  Felipe A Medeiros; Gianmarco Vizzeri; Linda M Zangwill; Luciana M Alencar; Pamela A Sample; Robert N Weinreb
Journal:  Ophthalmology       Date:  2008-01-22       Impact factor: 12.079

10.  Diagnosing preperimetric glaucoma with spectral domain optical coherence tomography.

Authors:  Renato Lisboa; Mauro T Leite; Linda M Zangwill; Ali Tafreshi; Robert N Weinreb; Felipe A Medeiros
Journal:  Ophthalmology       Date:  2012-08-09       Impact factor: 12.079

View more