Literature DB >> 20811060

Effect of disease severity and optic disc size on diagnostic accuracy of RTVue spectral domain optical coherence tomograph in glaucoma.

Harsha L Rao1, Mauro T Leite, Robert N Weinreb, Linda M Zangwill, Luciana M Alencar, Pamela A Sample, Felipe A Medeiros.   

Abstract

PURPOSE: To evaluate the effect of disease severity and optic disc size on the diagnostic accuracies of optic nerve head (ONH), retinal nerve fiber layer (RNFL), and macular parameters with RTVue (Optovue, Fremont, CA) spectral domain optical coherence tomography (SDOCT) in glaucoma.
METHODS: 110 eyes of 62 normal subjects and 193 eyes of 136 glaucoma patients from the Diagnostic Innovations in Glaucoma Study underwent ONH, RNFL, and macular imaging with RTVue. Severity of glaucoma was based on visual field index (VFI) values from standard automated perimetry. Optic disc size was based on disc area measurement using the Heidelberg Retina Tomograph II (Heidelberg Engineering, Dossenheim, Germany). Influence of disease severity and disc size on the diagnostic accuracy of RTVue was evaluated by receiver operating characteristic (ROC) and logistic regression models.
RESULTS: Areas under ROC curve (AUC) of all scanning areas increased (P < 0.05) as disease severity increased. For a VFI value of 99%, indicating early damage, AUCs for rim area, average RNFL thickness, and ganglion cell complex-root mean square were 0.693, 0.799, and 0.779, respectively. For a VFI of 70%, indicating severe damage, corresponding AUCs were 0.828, 0.985, and 0.992, respectively. Optic disc size did not influence the AUCs of any of the SDOCT scanning protocols of RTVue (P > 0.05). Sensitivity of the rim area increased and specificity decreased in large optic discs.
CONCLUSIONS: Diagnostic accuracies of RTVue scanning protocols for glaucoma were significantly influenced by disease severity. Sensitivity of the rim area increased in large optic discs at the expense of specificity.

Entities:  

Mesh:

Year:  2011        PMID: 20811060      PMCID: PMC3101678          DOI: 10.1167/iovs.10-5546

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  33 in total

1.  Accounting for the correlation between fellow eyes in regression analysis.

Authors:  R J Glynn; B Rosner
Journal:  Arch Ophthalmol       Date:  1992-03

2.  Detection of early glaucomatous structural damage with confocal scanning laser tomography.

Authors:  R Bathija; L Zangwill; C C Berry; P A Sample; R N Weinreb
Journal:  J Glaucoma       Date:  1998-04       Impact factor: 2.503

3.  The effect of optic disc size on diagnostic precision with the Heidelberg retina tomograph.

Authors:  M Iester; F S Mikelberg; S M Drance
Journal:  Ophthalmology       Date:  1997-03       Impact factor: 12.079

4.  The effects of study design and spectrum bias on the evaluation of diagnostic accuracy of confocal scanning laser ophthalmoscopy in glaucoma.

Authors:  Felipe A Medeiros; Diana Ng; Linda M Zangwill; Pamela A Sample; Christopher Bowd; Robert N Weinreb
Journal:  Invest Ophthalmol Vis Sci       Date:  2007-01       Impact factor: 4.799

5.  Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography.

Authors:  Felipe A Medeiros; Linda M Zangwill; Christopher Bowd; Roberto M Vessani; Remo Susanna; Robert N Weinreb
Journal:  Am J Ophthalmol       Date:  2005-01       Impact factor: 5.258

6.  Influence of disease severity and optic disc size on the diagnostic performance of imaging instruments in glaucoma.

Authors:  Felipe A Medeiros; Linda M Zangwill; Christopher Bowd; Pamela A Sample; Robert N Weinreb
Journal:  Invest Ophthalmol Vis Sci       Date:  2006-03       Impact factor: 4.799

7.  Assessment of a race-specific normative HRT-III database to differentiate glaucomatous from normal eyes.

Authors:  Joseph R Zelefsky; Noga Harizman; Ricardo Mora; Elena Ilitchev; Celso Tello; Robert Ritch; Jeffrey M Liebmann
Journal:  J Glaucoma       Date:  2006-12       Impact factor: 2.503

8.  Comparison of data analysis tools for detection of glaucoma with the Heidelberg Retina Tomograph.

Authors:  Bryce A Ford; Paul H Artes; Terry A McCormick; Marcelo T Nicolela; Raymond P LeBlanc; Balwantray C Chauhan
Journal:  Ophthalmology       Date:  2003-06       Impact factor: 12.079

9.  Comparison of retinal nerve fiber layer and optic disc imaging for diagnosing glaucoma in patients suspected of having the disease.

Authors:  Felipe A Medeiros; Gianmarco Vizzeri; Linda M Zangwill; Luciana M Alencar; Pamela A Sample; Robert N Weinreb
Journal:  Ophthalmology       Date:  2008-01-22       Impact factor: 12.079

10.  The influence of age, sex, race, refractive error and optic disc parameters on the sensitivity and specificity of scanning laser polarimetry.

Authors:  Vital P Costa; Roberto Lauande-Pimentel; Roberto A Fonseca; Leopoldo Magacho
Journal:  Acta Ophthalmol Scand       Date:  2004-08
View more
  27 in total

1.  Retinal nerve fiber layer and macular inner retina measurements by spectral domain optical coherence tomograph in Indian eyes with early glaucoma.

Authors:  H L Rao; J G Babu; U K Addepalli; S Senthil; C S Garudadri
Journal:  Eye (Lond)       Date:  2011-11-11       Impact factor: 3.775

2.  Glaucoma research community and FDA look to the future, II: NEI/FDA Glaucoma Clinical Trial Design and Endpoints Symposium: measures of structural change and visual function.

Authors:  Robert N Weinreb; Paul L Kaufman
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-10-04       Impact factor: 4.799

3.  Regression Analysis of Optical Coherence Tomography Disc Variables for Glaucoma Diagnosis.

Authors:  Grace M Richter; Xinbo Zhang; Ou Tan; Brian A Francis; Vikas Chopra; David S Greenfield; Rohit Varma; Joel S Schuman; David Huang
Journal:  J Glaucoma       Date:  2016-08       Impact factor: 2.503

4.  Relationship between ganglion cell layer thickness and estimated retinal ganglion cell counts in the glaucomatous macula.

Authors:  Chunwei Zhang; Andrew J Tatham; Robert N Weinreb; Linda M Zangwill; Zhiyong Yang; James Z Zhang; Felipe A Medeiros
Journal:  Ophthalmology       Date:  2014-08-20       Impact factor: 12.079

5.  Retinal nerve fiber layer evaluation of spectral domain optical coherence tomograph and scanning laser polarimeter to diagnose glaucoma.

Authors:  H L Rao; R K Yadav; U K Addepalli; S Chaudhary; S Senthil; N S Choudhari; C S Garudadri
Journal:  Eye (Lond)       Date:  2014-03-07       Impact factor: 3.775

6.  Comparison of the diagnostic accuracies of the Spectralis, Cirrus, and RTVue optical coherence tomography devices in glaucoma.

Authors:  Mauro T Leite; Harsha L Rao; Linda M Zangwill; Robert N Weinreb; Felipe A Medeiros
Journal:  Ophthalmology       Date:  2011-03-05       Impact factor: 12.079

7.  Estimating Lead Time Gained by Optical Coherence Tomography in Detecting Glaucoma before Development of Visual Field Defects.

Authors:  Tammy M Kuang; Chunwei Zhang; Linda M Zangwill; Robert N Weinreb; Felipe A Medeiros
Journal:  Ophthalmology       Date:  2015-07-18       Impact factor: 12.079

8.  Detecting glaucoma progression from localized rates of retinal changes in parametric and nonparametric statistical framework with type I error control.

Authors:  Madhusudhanan Balasubramanian; Ery Arias-Castro; Felipe A Medeiros; David J Kriegman; Christopher Bowd; Robert N Weinreb; Michael Holst; Pamela A Sample; Linda M Zangwill
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-03-19       Impact factor: 4.799

9.  Enhanced detection of open-angle glaucoma with an anatomically accurate optical coherence tomography-derived neuroretinal rim parameter.

Authors:  Balwantray C Chauhan; Neil O'Leary; Faisal A AlMobarak; Alexandre S C Reis; Hongli Yang; Glen P Sharpe; Donna M Hutchison; Marcelo T Nicolela; Claude F Burgoyne
Journal:  Ophthalmology       Date:  2012-12-23       Impact factor: 12.079

10.  Likelihood ratios for glaucoma diagnosis using spectral-domain optical coherence tomography.

Authors:  Renato Lisboa; Kaweh Mansouri; Linda M Zangwill; Robert N Weinreb; Felipe A Medeiros
Journal:  Am J Ophthalmol       Date:  2013-08-20       Impact factor: 5.258

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.