Literature DB >> 17189800

Profile of clear corneal cataract incisions demonstrated by ocular coherence tomography.

I Howard Fine1, Richard S Hoffman, Mark Packer.   

Abstract

PURPOSE: To examine the profile of clear corneal cataract incisions in the living eye using optical coherence tomography (OCT).
SETTING: Private practice, Eugene, Oregon, USA.
METHODS: The Zeiss Visante OCT anterior segment imaging system was used to study the profile of clear corneal cataract incisions, all in senior citizens. The OCT images of the operative eye were taken on the first postoperative day approximately 24 hours after surgery. The OCT images of clear corneal incisions were compared with an OCT image of a control eye, incisions without stromal hydration, and previous drawings of clear corneal incisions.
RESULTS: In the images, the clear corneal incisions had an arcuate configuration rather than a straight line configuration, as previously indicated. This architecture appears to add greater stability as a result of a tongue-and-groove-like fit of the floor to the roof of the incision as well as an incision that is longer than the chord length that had previously been measured. Other findings include that stromal swelling, which facilitates sealing of these incisions by the endothelial pump, lasted for at least 24 hours.
CONCLUSIONS: Results indicate an incision in the plane of the cornea with a chord length of at least 2.0 mm provides advantageous architecture for adequate self-sealing. Proper clear corneal incision construction resulted in an incision architecture that seemed to have increased stability and added safety, contributing to an absence of endophthalmitis for more than 10 years and 9000 cases in a single practice.

Entities:  

Mesh:

Year:  2007        PMID: 17189800     DOI: 10.1016/j.jcrs.2006.09.016

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  21 in total

1.  Comparison of clear corneal incision injuries between torsional and conventional phacoemulsification.

Authors:  Xu Chen; Yinghong Ji; Yi Lu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-07-20       Impact factor: 3.117

2.  Pathogens and antibiotic sensitivities in endophthalmitis.

Authors:  Geraldine R Slean; Neal H Shorstein; Liyan Liu; John F Paschal; Kevin L Winthrop; Lisa J Herrinton
Journal:  Clin Exp Ophthalmol       Date:  2017-01-31       Impact factor: 4.207

3.  In vivo and in vitro results of an automated preloaded delivery system for IOL implantation in cataract surgery.

Authors:  Leonardo Mastropasqua; Lisa Toto; Erminia D'Ugo; Manuela Lanzini; Peter A Mattei; Gennaro Falconio; Emanuele Doronzo; Francesca Diomede; Oriana Trubiani
Journal:  Int Ophthalmol       Date:  2019-08-26       Impact factor: 2.031

4.  Early changes in corneal edema following torsional phacoemulsification using anterior segment optical coherence tomography and Scheimpflug photography.

Authors:  Ying-Jun Li; Hyo-Jin Kim; Choun-Ki Joo
Journal:  Jpn J Ophthalmol       Date:  2011-05-11       Impact factor: 2.447

5.  Evaluation of Femtosecond Laser Intrastromal Incision Location Using Optical Coherence Tomography.

Authors:  Li Wang; Lai Jiang; Katie Hallahan; Zaina N Al-Mohtaseb; Douglas D Koch
Journal:  Ophthalmology       Date:  2017-04-12       Impact factor: 12.079

6.  OCT-documented incision features and natural history of clear corneal incisions used for bimanual microincision cataract surgery.

Authors:  Graham W Lyles; Kenneth L Cohen; Diana Lam
Journal:  Cornea       Date:  2011-06       Impact factor: 2.651

7.  Comparison of new motorized injector vs manual injector for implantation of foldable intraocular lenses on wound integrity: an ASOCT study.

Authors:  S Khokhar; R Sharma; B Patil; N Aron; S Gupta
Journal:  Eye (Lond)       Date:  2014-07-18       Impact factor: 3.775

8.  Safety Profile of Stromal Hydration of Clear Corneal Incisions with Cefuroxime in the Mouse Model.

Authors:  Mariya Moosajee; Dhani Tracey-White; Richard P Harbottle; Veronica Ferguson
Journal:  J Ocul Pharmacol Ther       Date:  2016-06-13       Impact factor: 2.671

9.  Three-dimensional spectral domain optical coherence tomography of a clear corneal cataract incision.

Authors:  Theodore Leng; Brandon J Lujan; Sonia H Yoo; Jianhua Wang
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2008 Jul-Aug

10.  Optical coherence tomography of clear corneal incisions for cataract surgery.

Authors:  Julie M Schallhorn; Maolong Tang; Yan Li; Jonathan C Song; David Huang
Journal:  J Cataract Refract Surg       Date:  2008-09       Impact factor: 3.351

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.