Literature DB >> 18777882

Three-dimensional spectral domain optical coherence tomography of a clear corneal cataract incision.

Theodore Leng1, Brandon J Lujan, Sonia H Yoo, Jianhua Wang.   

Abstract

A prototype 1,310-nm wavelength spectral domain optical coherence tomography (SD-OCT) instrument was constructed and mounted onto a conventional slit lamp for imaging of the anterior segment. The device had an axial resolution of 8 microm and was able to acquire real-time two-dimensional images at 14 frames/second and full three-dimensional datasets in approximately 7 seconds. An SD-OCT dataset of 100 B-scans, each consisting of 512 A-scans, was acquired from the left eye ofa patient who had undergone phacoemulsification with a clear corneal incision. The resulting dataset could be manipulated in three-dimensional space to analyze the geometry of the wound. Additionally, stromal edema and iris features were clearly imaged with the device. SD-OCT can be used to analyze clear corneal incisions to determine optimal wound construction technique and geometry as they relate to the prevention of complications such as postoperative wound leak, infection, and epithelial ingrowth.

Entities:  

Mesh:

Year:  2008        PMID: 18777882      PMCID: PMC3397172          DOI: 10.3928/15428877-20080715-08

Source DB:  PubMed          Journal:  Ophthalmic Surg Lasers Imaging        ISSN: 1542-8877


  8 in total

1.  Real-time in vivo imaging by high-speed spectral optical coherence tomography.

Authors:  Maciej Wojtkowski; Tomasz Bajraszewski; Piotr Targowski; Andrzej Kowalczyk
Journal:  Opt Lett       Date:  2003-10-01       Impact factor: 3.776

2.  Trends in refractive surgery in the United States.

Authors:  Richard J Duffey; David Leaming
Journal:  J Cataract Refract Surg       Date:  2004-08       Impact factor: 3.351

3.  In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography.

Authors:  Nader Nassif; Barry Cense; B Hyle Park; Seok H Yun; Teresa C Chen; Brett E Bouma; Guillermo J Tearney; Johannes F de Boer
Journal:  Opt Lett       Date:  2004-03-01       Impact factor: 3.776

4.  Is there a relationship between clear corneal cataract incisions and endophthalmitis?

Authors:  Samuel Masket
Journal:  J Cataract Refract Surg       Date:  2005-04       Impact factor: 3.351

5.  Profile of clear corneal cataract incisions demonstrated by ocular coherence tomography.

Authors:  I Howard Fine; Richard S Hoffman; Mark Packer
Journal:  J Cataract Refract Surg       Date:  2007-01       Impact factor: 3.351

6.  Spectral optical coherence tomography: a novel technique for cornea imaging.

Authors:  Bartłomiej J Kaluzny; Bartłomiej J Kaluzy; Jakub J Kałuzny; Anna Szkulmowska; Iwona Gorczyńska; Maciej Szkulmowski; Tomasz Bajraszewski; Maciej Wojtkowski; Piotr Targowski
Journal:  Cornea       Date:  2006-09       Impact factor: 2.651

7.  Clear corneal incision architecture in the immediate postoperative period evaluated using optical coherence tomography.

Authors:  Daniel Calladine; Richard Packard
Journal:  J Cataract Refract Surg       Date:  2007-08       Impact factor: 3.351

8.  Acute-onset endophthalmitis after cataract surgery (2000-2004): incidence, clinical settings, and visual acuity outcomes after treatment.

Authors:  John J Miller; Ingrid U Scott; Harry W Flynn; William E Smiddy; Jean Newton; Darlene Miller
Journal:  Am J Ophthalmol       Date:  2005-06       Impact factor: 5.258

  8 in total
  3 in total

Review 1.  Three dimensional optical coherence tomography imaging: advantages and advances.

Authors:  Michelle L Gabriele; Gadi Wollstein; Hiroshi Ishikawa; Juan Xu; Jongsick Kim; Larry Kagemann; Lindsey S Folio; Joel S Schuman
Journal:  Prog Retin Eye Res       Date:  2010-06-11       Impact factor: 21.198

2.  Wavefront Derived Refraction and Full Eye Biometry in Pseudophakic Eyes.

Authors:  Xinjie Mao; James T Banta; Bilian Ke; Hong Jiang; Jichang He; Che Liu; Jianhua Wang
Journal:  PLoS One       Date:  2016-03-24       Impact factor: 3.240

3.  Simultaneous real-time imaging of the ocular anterior segment including the ciliary muscle during accommodation.

Authors:  Yilei Shao; Aizhu Tao; Hong Jiang; Meixiao Shen; Jianguang Zhong; Fan Lu; Jianhua Wang
Journal:  Biomed Opt Express       Date:  2013-02-21       Impact factor: 3.732

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.