Literature DB >> 14716792

Randomized clinical trial of lightweight composite mesh for Lichtenstein inguinal hernia repair.

S Post1, B Weiss, M Willer, T Neufang, D Lorenz.   

Abstract

BACKGROUND: Almost half the patients who undergo hernia repair with mesh report a feeling of stiffness and a foreign body in the groin. This study evaluated whether patients noticed any difference between lightweight and standard polypropylene mesh for the repair of inguinal hernia.
METHODS: Patients scheduled for elective repair of unilateral or bilateral, primary or recurrent inguinal hernia by the Lichtenstein technique were randomized to receive either a conventional densely woven polypropylene mesh (100-110 g/m(2)) or a lightweight composite multifilament mesh (polypropylene 27-30 g/m(2)). Quality of life was assessed using Short Form 36 before operation and 6 months after surgery. Pain was assessed by means of a visual analogue scale 2 days and 6 months after surgery. The primary outcome measure was the feeling of a foreign body in the groin at 6 months.
RESULTS: Some 122 hernias were randomized; 117 were included in the analysis of perioperative data, and 106 were re-examined after 6 months. There were no differences between the treatment groups with respect to early and late surgical complications. Use of lightweight mesh was associated with significantly less pain on exercise after 6 months (P = 0.042). In addition, fewer patients reported the feeling of a foreign body after repair with lightweight mesh (17.2 versus 43.8 per cent with conventional mesh; P = 0.003). Quality of life was improved significantly at 6 months compared with the preoperative assessment, and there were no differences between the treatment groups.
CONCLUSION: Lightweight polypropylene mesh may be preferable for Lichtenstein repair of inguinal hernia. Larger cohorts with longer follow-up are needed before it can be recommended for routine use. Copyright 2003 British Journal of Surgery Society Ltd.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14716792     DOI: 10.1002/bjs.4387

Source DB:  PubMed          Journal:  Br J Surg        ISSN: 0007-1323            Impact factor:   6.939


  73 in total

1.  Randomised clinical trial: conventional Lichtenstein vs. hernioplasty with self-adhesive mesh in bilateral inguinal hernia surgery.

Authors:  Jose L Porrero; María J Castillo; Ana Pérez-Zapata; María T Alonso; Oscar Cano-Valderrama; Esther Quirós; Sol Villar; Beatriz Ramos; Carlos Sánchez-Cabezudo; Oscar Bonachia; Alberto Marcos; Brígido Pérez
Journal:  Hernia       Date:  2014-11-04       Impact factor: 4.739

Review 2.  Inguinal hernia repair: current surgical techniques.

Authors:  R Bittner; J Schwarz
Journal:  Langenbecks Arch Surg       Date:  2011-11-25       Impact factor: 3.445

3.  Inflammatory reaction and neotissue maturation in the early host tissue incorporation of polypropylene prostheses.

Authors:  G Pascual; M Rodríguez; S Sotomayor; B Pérez-Köhler; J M Bellón
Journal:  Hernia       Date:  2012-06-29       Impact factor: 4.739

4.  Self-fixating mesh for the Lichtenstein procedure--a prestudy.

Authors:  Matthias Kapischke; Heiko Schulze; Amke Caliebe
Journal:  Langenbecks Arch Surg       Date:  2010-02-20       Impact factor: 3.445

5.  Early results for new lightweight mesh in laparoscopic totally extra-peritoneal inguinal hernia repair.

Authors:  L R Khan; S Kumar; S J Nixon
Journal:  Hernia       Date:  2006-06-10       Impact factor: 4.739

Review 6.  Improving outcomes in hernia repair by the use of light meshes--a comparison of different implant constructions based on a critical appraisal of the literature.

Authors:  Dirk Weyhe; Orlin Belyaev; Christophe Müller; Kirsten Meurer; Karl-Heinz Bauer; Georgios Papapostolou; Waldemar Uhl
Journal:  World J Surg       Date:  2007-01       Impact factor: 3.352

7.  Factors predicting chronic pain after open inguinal hernia repair: a regression analysis of randomized trial comparing three different meshes with three fixation methods (FinnMesh Study).

Authors:  M Matikainen; E Aro; J Vironen; J Kössi; T Hulmi; S Silvasti; I Ilves; M Hertsi; K Mustonen; H Paajanen
Journal:  Hernia       Date:  2018-05-04       Impact factor: 4.739

8.  Patient-centered outcomes following laparoscopic inguinal hernia repair.

Authors:  Michael B Ujiki; Matthew E Gitelis; Joann Carbray; Brittany Lapin; John Linn; Steven Haggerty; Chi Wang; Ryota Tanaka; Ermilo Barrera; Zeeshan Butt; Woody Denham
Journal:  Surg Endosc       Date:  2014-12-06       Impact factor: 4.584

9.  Early results of a randomized multicenter trial comparing Prolene and VyproII mesh in bilateral endoscopic extraperitoneal hernioplasty (TEP).

Authors:  S Bringman; S Wollert; J Osterberg; T Heikkinen
Journal:  Surg Endosc       Date:  2005-03-11       Impact factor: 4.584

10.  Fibrin sealing versus stapling of hernia meshes in an onlay model in the rat.

Authors:  Alexander H Petter-Puchner; R Fortelny; R Mittermayr; W Ohlinger; H Redl
Journal:  Hernia       Date:  2005-08-02       Impact factor: 4.739