Literature DB >> 17169598

The material mapping strategy influences the accuracy of CT-based finite element models of bones: an evaluation against experimental measurements.

Fulvia Taddei1, Enrico Schileo, Benedikt Helgason, Luca Cristofolini, Marco Viceconti.   

Abstract

Aim of the present study was to evaluate the influence on the global model's accuracy of the strategy adopted to define the average element Young's modulus in subject-specific finite element models of bones from computed tomography data. The classic strategy of calculating the Young's modulus from an average element density and the one that averages the Young's moduli directly derived from each voxel Hounsfield Unit were considered. These strategies were applied to the finite element model of a real human femur. The accuracy of the superficial stress and strain predictions was evaluated against experimentally measured values in 13 strain-gauge locations for five different loading conditions. The results obtained for the two material distributions were statistically different. Both models predicted very accurately the superficial stresses, with regression coefficients higher than 0.9 and slopes not significantly different from unity. The second strategy definitely improved the strains prediction accuracy: the regression coefficient raised from 0.69 to 0.79; the average and peak errors decreased from 45.1% to 31.3% and from 228% to 134% of the maximum measured strain, respectively. The stress fields predicted inside the bone were also significantly different. A new software implementing the second strategy was made available in the public domain.

Entities:  

Mesh:

Year:  2006        PMID: 17169598     DOI: 10.1016/j.medengphy.2006.10.014

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  33 in total

Review 1.  Finite Element-Based Mechanical Assessment of Bone Quality on the Basis of In Vivo Images.

Authors:  Dieter H Pahr; Philippe K Zysset
Journal:  Curr Osteoporos Rep       Date:  2016-12       Impact factor: 5.096

2.  Voxel-based micro-finite element analysis of dental implants in a human cadaveric mandible: Tissue modulus assignment and sensitivity analyses.

Authors:  Qiyuan Mao; Kangning Su; Yuxiao Zhou; Mehran Hossaini-Zadeh; Gregory S Lewis; Jing Du
Journal:  J Mech Behav Biomed Mater       Date:  2019-03-13

3.  [Applications of numerical simulation in musculoskeletal research and its impact on orthopedic surgery].

Authors:  D Kluess; C Hurschler; C Voigt; A Hölzer; M Stoffel
Journal:  Orthopade       Date:  2013-04       Impact factor: 1.087

4.  Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. II. Experiment.

Authors:  Jang-Hwan Choi; Andreas Maier; Andreas Keil; Saikat Pal; Emily J McWalter; Gary S Beaupré; Garry E Gold; Rebecca Fahrig
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

5.  Material Mapping of QCT-Derived Scapular Models: A Comparison with Micro-CT Loaded Specimens Using Digital Volume Correlation.

Authors:  Nikolas K Knowles; Jonathan Kusins; Mohammadreza Faieghi; Melissa Ryan; Enrico Dall'Ara; Louis M Ferreira
Journal:  Ann Biomed Eng       Date:  2019-07-11       Impact factor: 3.934

6.  Increased Hip Stresses Resulting From a Cam Deformity and Decreased Femoral Neck-Shaft Angle During Level Walking.

Authors:  K C Geoffrey Ng; Giulia Mantovani; Mario Lamontagne; Michel R Labrosse; Paul E Beaulé
Journal:  Clin Orthop Relat Res       Date:  2017-04       Impact factor: 4.176

Review 7.  Patient-Specific Bone Multiscale Modelling, Fracture Simulation and Risk Analysis-A Survey.

Authors:  Amadeus C S de Alcântara; Israel Assis; Daniel Prada; Konrad Mehle; Stefan Schwan; Lucia Costa-Paiva; Munir S Skaf; Luiz C Wrobel; Paulo Sollero
Journal:  Materials (Basel)       Date:  2019-12-24       Impact factor: 3.623

8.  Left-right differences in the proximal femur's strength of post-menopausal women: a multicentric finite element study.

Authors:  F Taddei; C Falcinelli; L Balistreri; P Henys; F Baruffaldi; S Sigurdsson; V Gudnason; T B Harris; R Dietzel; G Armbrecht; S Boutroy; E Schileo
Journal:  Osteoporos Int       Date:  2015-11-17       Impact factor: 4.507

Review 9.  Osteoporosis drug effects on cortical and trabecular bone microstructure: a review of HR-pQCT analyses.

Authors:  Eric Lespessailles; Ridha Hambli; Serge Ferrari
Journal:  Bonekey Rep       Date:  2016-08-31

Review 10.  A biomechanical sorting of clinical risk factors affecting osteoporotic hip fracture.

Authors:  Y Luo
Journal:  Osteoporos Int       Date:  2015-09-11       Impact factor: 4.507