Literature DB >> 30925312

Voxel-based micro-finite element analysis of dental implants in a human cadaveric mandible: Tissue modulus assignment and sensitivity analyses.

Qiyuan Mao1, Kangning Su2, Yuxiao Zhou3, Mehran Hossaini-Zadeh4, Gregory S Lewis5, Jing Du6.   

Abstract

The success of dental implant treatment is related to the complex 3-dimensional (3D) biomechanics of the implant-bone interaction. In this work, 3D numerical models are built based on micro X-ray computed tomography (micro-CT) images of a cadaveric mandible specimen with implants placed in it. The simulation results show that the computed strain values in bone are sensitive to the uncertainties in trabecular tissue modulus and fairly insensitive to the modulus of implants and teeth and the detailed geometry of the fixed boundary condition. A bone-volume-fraction (BV/TV) based method is proposed to assign the tissue moduli of bone elements based on their BV/TV to increase the connectivity of the mesh and to improve the accuracy of the models. These models are potentially powerful for calculating the 3D full-field bone strain under implant loading, enabling in silico testing of different implant designs, but demand validation of the models. The computed results reveal high strain concentration at bone-implant contact areas and, more importantly, in the buccal (lip-side) bone that is not making contact with the implant. The computed strain concentration patterns are found to be in good agreement with the observations from our prior experiments using 3D full-field mechanical testing coupled with micro-CT and digital volume correlation. The buccal bone is thinner and less stiff than other areas of bone and is also the commonly observed area of bone resorption after dental implant treatment.
Copyright © 2019 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Bone volume fraction; Dental implant; Finite element method; Micro-CT

Year:  2019        PMID: 30925312      PMCID: PMC6636627          DOI: 10.1016/j.jmbbm.2019.03.008

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  42 in total

1.  Elastic properties of microstructural components of human bone tissue as measured by nanoindentation.

Authors:  J Y Rho; M E Roy; T Y Tsui; G M Pharr
Journal:  J Biomed Mater Res       Date:  1999-04

2.  Convergence behavior of high-resolution finite element models of trabecular bone.

Authors:  G L Niebur; J C Yuen; A C Hsia; T M Keaveny
Journal:  J Biomech Eng       Date:  1999-12       Impact factor: 2.097

3.  The influence of bone volume fraction and ash fraction on bone strength and modulus.

Authors:  C J Hernandez; G S Beaupré; T S Keller; D R Carter
Journal:  Bone       Date:  2001-07       Impact factor: 4.398

4.  The elastic and ultimate properties of compact bone tissue.

Authors:  D T Reilly; A H Burstein
Journal:  J Biomech       Date:  1975       Impact factor: 2.712

5.  A mimic osseointegrated implant model for three-dimensional finite element analysis.

Authors:  Y Akagawa; Y Sato; E R Teixeira; N Shindoi; M Wadamoto
Journal:  J Oral Rehabil       Date:  2003-01       Impact factor: 3.837

6.  Individualised, micro CT-based finite element modelling as a tool for biomechanical analysis related to tissue engineering of bone.

Authors:  S V N Jaecques; H Van Oosterwyck; L Muraru; T Van Cleynenbreugel; E De Smet; M Wevers; I Naert; J Vander Sloten
Journal:  Biomaterials       Date:  2004-04       Impact factor: 12.479

7.  Three-dimensional finite element modelling of bone: effects of element size.

Authors:  J H Keyak; H B Skinner
Journal:  J Biomed Eng       Date:  1992-11

8.  Tensile and compressive strength of human parietal bone.

Authors:  F G EVANS; H R LISSNER
Journal:  J Appl Physiol       Date:  1957-05       Impact factor: 3.531

9.  Comparison of the linear finite element prediction of deformation and strain of human cancellous bone to 3D digital volume correlation measurements.

Authors:  R Zauel; Y N Yeni; B K Bay; X N Dong; D P Fyhrie
Journal:  J Biomech Eng       Date:  2006-02       Impact factor: 2.097

10.  A comparison of the fatigue behavior of human trabecular and cortical bone tissue.

Authors:  K Choi; S A Goldstein
Journal:  J Biomech       Date:  1992-12       Impact factor: 2.712

View more
  6 in total

Review 1.  Biomechanical behaviours of the bone-implant interface: a review.

Authors:  Xing Gao; Manon Fraulob; Guillaume Haïat
Journal:  J R Soc Interface       Date:  2019-07-31       Impact factor: 4.118

2.  3D full-field strain in bone-implant and bone-tooth constructs and their morphological influential factors.

Authors:  Yuxiao Zhou; Chujie Gong; Mehran Hossaini-Zadeh; Jing Du
Journal:  J Mech Behav Biomed Mater       Date:  2020-05-19

3.  Micromechanical modeling of the contact stiffness of an osseointegrated bone-implant interface.

Authors:  Maria Letizia Raffa; Vu-Hieu Nguyen; Guillaume Haiat
Journal:  Biomed Eng Online       Date:  2019-12-03       Impact factor: 2.819

4.  Effects of implant buccal distance on peri-implant strain: A Micro-CT based finite element analysis.

Authors:  Kangning Su; Yuxiao Zhou; Mehran Hossaini-Zadeh; Jing Du
Journal:  J Mech Behav Biomed Mater       Date:  2021-01-13

Review 5.  Validated Finite Element Models of Premolars: A Scoping Review.

Authors:  Raphaël Richert; Jean-Christophe Farges; Faleh Tamimi; Naim Naouar; Philippe Boisse; Maxime Ducret
Journal:  Materials (Basel)       Date:  2020-07-23       Impact factor: 3.623

Review 6.  Bioengineering Tools Applied to Dentistry: Validation Methods for In Vitro and In Silico Analysis.

Authors:  Jefferson David Melo de Matos; Daher Antonio Queiroz; Leonardo Jiro Nomura Nakano; Valdir Cabral Andrade; Nathália de Carvalho Ramos Ribeiro; Alexandre Luiz Souto Borges; Marco Antonio Bottino; Guilherme da Rocha Scalzer Lopes
Journal:  Dent J (Basel)       Date:  2022-08-04
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.