Literature DB >> 17159169

Simultaneous in vitro measurement of patellofemoral kinematics and forces following Oxford medial unicompartmental knee replacement.

A J Price1, P T Oppold, D W Murray, A B Zavatsky.   

Abstract

The Oxford medial unicompartmental knee replacement was designed to reproduce normal mobility and forces in the knee, but its detailed effect on the patellofemoral joint has not been studied previously. We have examined the effect on patellofemoral mechanics of the knee by simultaneously measuring patellofemoral kinematics and forces in 11 cadaver knee specimens in a supine leg-extension rig. Comparison was made between the intact normal knee and sequential unicompartmental and total knee replacement. Following medial mobile-bearing unicompartmental replacement in 11 knees, patellofemoral kinematics and forces did not change significantly from those in the intact knee across any measured parameter. In contrast, following posterior cruciate ligament retaining total knee replacement in eight knees, there were significant changes in patellofemoral movement and forces. The Oxford device appears to produce near-normal patellofemoral mechanics, which may partly explain the low incidence of complications with the extensor mechanism associated with clinical use.

Entities:  

Mesh:

Year:  2006        PMID: 17159169     DOI: 10.1302/0301-620X.88B12.18306

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  13 in total

1.  In vivo sagittal plane kinematics of the FPV patellofemoral replacement.

Authors:  A P Monk; B H van Duren; H Pandit; D Shakespeare; D W Murray; H S Gill
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-19       Impact factor: 4.342

Review 2.  [Patella position and patellofemoral osteoarthritis after unicompartmental arthroplasty].

Authors:  K Anagnostakos; O Lorbach; D Kohn; P Orth
Journal:  Orthopade       Date:  2014-10       Impact factor: 1.087

3.  Muscle activity around the knee and gait performance in unicompartmental knee arthroplasty patients: a comparative study on fixed- and mobile-bearing designs.

Authors:  Fabio Catani; Maria Grazia Benedetti; Luca Bianchi; Valentina Marchionni; Sandro Giannini; Alberto Leardini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-08-10       Impact factor: 4.342

4.  Constraints in posterior-stabilised TKA kinematics: a comparison of two generations of an implant.

Authors:  Hemant Pandit; Bernard Hendrik van Duren; M Price; S Tilley; Harinderjit Singh Gill; Neil P Thomas; David W Murray
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-10-11       Impact factor: 4.342

5.  The influence of third-body particles on wear rate in unicondylar knee arthroplasty: a wear simulator study with bone and cement debris.

Authors:  Christian Schroeder; Thomas M Grupp; Bernhard Fritz; Christoph Schilling; Yan Chevalier; Sandra Utzschneider; Volkmar Jansson
Journal:  J Mater Sci Mater Med       Date:  2013-02-17       Impact factor: 3.896

6.  [Unicompartimental joint (Oxford III) with mobile bearing : Minimally invasive implantation of a in the medial compartiment].

Authors:  W Petersen; S Metzlaff; P Forkel; A Achtnich; K Schmoranzer; P Hertel
Journal:  Oper Orthop Traumatol       Date:  2013-10       Impact factor: 1.154

7.  Bicruciate substituting total knee replacement: how effective are the added kinematic constraints in vivo?

Authors:  B H van Duren; H Pandit; M Price; S Tilley; H S Gill; D W Murray; N P Thomas
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-29       Impact factor: 4.342

8.  Does bearing design influence midterm survivorship of unicompartmental arthroplasty?

Authors:  John-Paul Whittaker; Douglas D R Naudie; James P McAuley; Richard W McCalden; Steven J MacDonald; Robert B Bourne
Journal:  Clin Orthop Relat Res       Date:  2009-07-14       Impact factor: 4.176

9.  [Experience with medial unicompartmental prostheses with a mobile plateau].

Authors:  M F Pietschmann; P Weber; A Steinbrück; L Wohlleb; V Jansson; P E Müller
Journal:  Orthopade       Date:  2014-10       Impact factor: 1.087

10.  Which one restores in vivo knee kinematics effectively-medial or lateral pivot?

Authors:  Sahil Batra; Pon Aravindhan A Sugumar; Vijay Kumar; Rajesh Malhotra
Journal:  J Clin Orthop Trauma       Date:  2020-08-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.