In vivo dosimetry by an aSi-based EPID.

Angelo Piermattei1, Andrea Fidanzio, Gerardina Stimato, Luigi Azario, Luca Grimaldi, Guido D'Onofrio, Savino Cilla, Mario Balducci, Maria Antonietta Gambacorta, Nicola Di Napoli, Numa Cellini.   

Abstract

A method for the in vivo determination of the isocenter dose, Diso, and mid-plane dose, Dm, using the transmitted signal St measured by 25 central pixels of an aSi-based EPID is here reported. The method has been applied to check the conformal radiotherapy of pelvic tumors and supplies accurate in vivo dosimetry avoiding many of the disadvantages associated with the use of two diode detectors (at the entrance and exit of the patient) as their periodic recalibration and their positioning. Irradiating water-equivalent phantoms of different thicknesses, a set of correlation functions F(w, l) were obtained by the ratio between St and Dm as a function of the phantom thickness, w, for a different field width, l. For the in vivo determination of Diso and Dm values, the water-equivalent thickness of the patients (along the beam central axis) was evaluated by means of the treatment planning system that uses CT scans calibrated in terms of the electron densities. The Diso and Dm values experimentally determined were compared with the stated doses D(iso,TPS) and D(m,TPS), determined by the treatment planning system for ten pelvic treatments. In particular, for each treatment four fields were checked in six fractions. In these conditions the agreement between the in vivo dosimetry and stated doses at the isocenter point were within 3%. Comparing the 480 dose values obtained in this work with those obtained for 30 patients tested with a similar method, which made use of a small ion-chamber positioned on the EPIDs to obtain the transmitted signal, a similar agreement was observed. The method here proposed is very practical and can be applied in every treatment fraction, supplying useful information about eventual patient dose variations due to the incorrect application of the quality assurance program based on the check of patient setup, machine setting, and calculations.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17153420     DOI: 10.1118/1.2360014

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  19 in total

1.  A generalized calibration procedure for in vivo transit dosimetry using siemens electronic portal imaging devices.

Authors:  Andrea Fidanzio; Francesca Greco; Laura Gargiulo; Savino Cilla; Domenico Sabatino; Massimo Cappiello; Cinzia Di Felice; Elisabetta Di Castro; Luigi Azario; Mariateresa Russo; Luciano Pompei; Guido D'Onofrio; Angelo Piermattei
Journal:  Med Biol Eng Comput       Date:  2010-11-04       Impact factor: 2.602

2.  A dual two dimensional electronic portal imaging device transit dosimetry model based on an empirical quadratic formalism.

Authors:  Y I Tan; M Metwaly; M Glegg; S P Baggarley; A Elliott
Journal:  Br J Radiol       Date:  2015-05-13       Impact factor: 3.039

3.  A validation study of a dedicated software for an automated in vivo dosimetry control in radiotherapy.

Authors:  A Piermattei; F Greco; M Grusio; S Menna; L Azario; G Stimato; E Placidi; S Teodoli; S Cilla; A Porcelli; L Alberico; A Fidanzio
Journal:  Med Biol Eng Comput       Date:  2018-04-23       Impact factor: 2.602

4.  Dose-guided radiotherapy for lung tumors.

Authors:  Angelo Piermattei; Andrea Fidanzio; Savino Cilla; Francesca Greco; Luigi Azario; Domenico Sabatino; Mattia Grusio; Mariella Cozzolino; Vincenzo Fusco
Journal:  Med Biol Eng Comput       Date:  2009-12-10       Impact factor: 2.602

5.  In patient dose reconstruction using a cine acquisition for dynamic arc radiation therapy.

Authors:  Angelo Piermattei; Andrea Fidanzio; Luigi Azario; Francesca Greco; Alessandra Mameli; Savino Cilla; Luca Grimaldi; Guido D'Onofrio; Boris Giuseppe Augelli; Gerardina Stimato; Diego Gaudino; Sara Ramella; Rolando D'Angelillo; Francesco Cellini; Lucio Trodella
Journal:  Med Biol Eng Comput       Date:  2009-02-17       Impact factor: 2.602

6.  Current concepts on imaging in radiotherapy.

Authors:  Michela Lecchi; Piero Fossati; Federica Elisei; Roberto Orecchia; Giovanni Lucignani
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-10-31       Impact factor: 9.236

7.  Commissioning and Evaluation of an Electronic Portal Imaging Device-Based In-Vivo Dosimetry Software.

Authors:  Mareike Held; Joey Cheung; Angelica Perez Andujar; François Husson; Olivier Morin
Journal:  Cureus       Date:  2018-02-02

8.  A Simple Method for 2-D In Vivo Dosimetry by Portal Imaging.

Authors:  Stefano Peca; Derek Wilson Brown; Wendy Lani Smith
Journal:  Technol Cancer Res Treat       Date:  2017-06-06

9.  Breast in vivo dosimetry by EPID.

Authors:  Andrea Fidanzio; Francesca Greco; Alessandra Mameli; Luigi Azario; Mario Balducci; Maria Antonietta Gambacorta; Vincenzo Frascino; Savino Cilla; Domenico Sabatino; Angelo Piermattei
Journal:  J Appl Clin Med Phys       Date:  2010-09-02       Impact factor: 2.102

10.  EPID-based daily verification of reproducibility of patients' irradiation with IMRT plans.

Authors:  Marta Kruszyna-Mochalska
Journal:  Rep Pract Oncol Radiother       Date:  2018-08-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.