Literature DB >> 17137982

Accuracy of intraocular lens power prediction using the Hoffer Q, Holladay 1, Holladay 2, and SRK/T formulas.

Julio Narváez1, Grenith Zimmerman, R Doyle Stulting, Daniel H Chang.   

Abstract

PURPOSE: To compare the accuracy of intraocular lens (IOL) power calculations using 4 formulas: Hoffer Q, Holladay 1, Holladay 2, and SRK/T.
SETTING: Tertiary care center.
METHODS: This study was a retrospective comparative analysis. Immersion ultrasound biometry (axial length, anterior chamber depth, and lens thickness), manual keratometry, and postoperative manifest refraction were obtained in 643 eyes of consecutive patients who had routine uneventful cataract surgery with implantation of 1 of 2 IOLs using the same operative technique by the same surgeon. Biometric data were entered into each of the 4 IOL power calculation formulas, and the results were compared to the final manifest refraction. An optimized lens constant was used for each formula. Results were also stratified into groups of short, average, medium long, and very long axial length <22.0 mm, 22.0 to <24.5 mm, 24.5 to 26.0 mm, and >26.0 mm, respectively).
RESULTS: No formula was more accurate than the others as measured by mean absolute error. The formulas were also equally accurate when eyes were stratified by axial length.
CONCLUSION: The 4 IOL power formulas provided equivalent refractive results in the entire group of eyes and in the subsets of axial lengths tested.

Entities:  

Mesh:

Year:  2006        PMID: 17137982     DOI: 10.1016/j.jcrs.2006.09.009

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  47 in total

1.  Comparison of the biometric formulas used for applanation A-scan ultrasound biometry.

Authors:  Fatih Özcura; Serdar Aktaş; Hacı Murat Sağdık; Mehmet Tetikoğlu
Journal:  Int Ophthalmol       Date:  2016-02-08       Impact factor: 2.031

2.  Evaluation of biometry and corneal astigmatism in cataract surgery patients in Northern United Arab Emirates.

Authors:  Eui Seok Han; Moonjung Kim
Journal:  Int Ophthalmol       Date:  2019-05-27       Impact factor: 2.031

3.  Intra-ocular lens power calculation in patients with high axial myopia before cataract surgery.

Authors:  Raouf El-Nafees; Ashraf Moawad; Hanem Kishk; Walid Gaafar
Journal:  Saudi J Ophthalmol       Date:  2010-04-04

4.  Prevalence of corneal astigmatism before cataract surgery.

Authors:  Mehran Mohammadi; Mohammad Naderan; Rozhin Pahlevani; Ali Jahanrad
Journal:  Int Ophthalmol       Date:  2016-02-24       Impact factor: 2.031

5.  Respond to: A study regarding efficacy of various intraocular lens power calculation formulas in a subset of Indian myopic population.

Authors:  Ashish Mitra; Elesh Jain; Alok Sen; Shubhi Tripathi
Journal:  Indian J Ophthalmol       Date:  2015-03       Impact factor: 1.848

6.  A study to evaluate whether CTR increases refractive unpredictability between predicted and actual IOL position.

Authors:  V K Baranwal; Santosh Kumar; Avinash Mishra; Ajay K Dutta
Journal:  Med J Armed Forces India       Date:  2012-10-31

7.  Errors associated with IOLMaster biometry as a function of internal ocular dimensions.

Authors:  Miguel Faria-Ribeiro; Daniela Lopes-Ferreira; Norberto López-Gil; Jorge Jorge; José Manuel González-Méijome
Journal:  J Optom       Date:  2014-01-28

8.  Scheimpflug camera combined with placido-disk corneal topography and optical biometry for intraocular lens power calculation.

Authors:  Ahmet Kirgiz; Kurşat Atalay; Havva Kaldirim; Kubra Serefoglu Cabuk; Mehmet Orcun Akdemir; Muhittin Taskapili
Journal:  Int Ophthalmol       Date:  2016-09-01       Impact factor: 2.031

9.  A Comparative Study to Assess the Predictability of Different IOL Power Calculation Formulas in Eyes of Short and Long Axial Length.

Authors:  Dharmil Doshi; Purvi Limdi; Nilesh Parekh; Neepa Gohil
Journal:  J Clin Diagn Res       Date:  2017-01-01

10.  Clinical application of bicylindric intraocular lens power calculation method.

Authors:  Jorge A Calvo-Sanz; Cristina Bonnin-Arias; Alfonso Arias-Puente
Journal:  Indian J Ophthalmol       Date:  2020-06       Impact factor: 1.848

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.