Literature DB >> 11717063

Dose and pitch relationship for a particular multislice CT scanner.

M Mahesh1, J C Scatarige, J Cooper, E K Fishman.   

Abstract

OBJECTIVE: With single-slice helical CT, an increased pitch can decrease the radiation dose to the patient if all other parameters are constant. The purpose of this study was to determine whether the same relationship holds for a particular multislice helical CT system (Somatom Plus 4 VZ multislice helical CT scanner, version A11A) in our department.
CONCLUSION: The measured radiation dose to the phantom was identical for all pitch selections on the multislice helical CT system we tested. This unexpected result was because of an automatic proportionate increase in the tube current when the pitch selection was increased. Radiologists and physicists should exercise caution when extrapolating dose reduction strategies from single-slice to multislice helical CT systems, and they must acquire a detailed understanding of the multislice helical CT scanner of their chosen manufacturer.

Entities:  

Mesh:

Year:  2001        PMID: 11717063     DOI: 10.2214/ajr.177.6.1771273

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  18 in total

Review 1.  Recognition, assessment, and treatment of non-union after surgical fixation of fractures: emphasis on 3D CT.

Authors:  Cuneyt Calisir; Laura M Fayad; John A Carrino; Elliot K Fishman
Journal:  Jpn J Radiol       Date:  2011-12-10       Impact factor: 2.374

2.  Pulmonary embolism: is multislice CT the method of choice? Against.

Authors:  Carl Schuemichen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-01       Impact factor: 9.236

3.  Reduction of the unnecessary dose from the over-range area with a spiral dynamic z-collimator: comparison of beam pitch and detector coverage with 128-detector row CT.

Authors:  Takashi Shirasaka; Yoshinori Funama; Mutsukazu Hayashi; Shinichi Awamoto; Masatoshi Kondo; Yasuhiko Nakamura; Masamitsu Hatakenaka; Hiroshi Honda
Journal:  Radiol Phys Technol       Date:  2011-10-15

4.  Effect of total lung capacity and gender on CT densitometry indexes.

Authors:  Michel Walsdorff; Alain Van Muylem; Pierre Alain Gevenois
Journal:  Br J Radiol       Date:  2015-11-11       Impact factor: 3.039

5.  Low Dose MDCT with Tube Current Modulation: Role in Detection of Urolithiasis and Patient Effective Dose Reduction.

Authors:  Prakashini Koteshwar; Chandan Kakkar; Smiti Sripathi; Anushri Parakh; Rajendra Shrivastav
Journal:  J Clin Diagn Res       Date:  2016-05-01

6.  Urinary calculi: improved detection and characterization with thin-slice multidetector CT.

Authors:  Etienne Ketelslegers; Bernard E Van Beers
Journal:  Eur Radiol       Date:  2005-06-16       Impact factor: 5.315

7.  Irreversible JPEG 2000 compression of abdominal CT for primary interpretation: assessment of visually lossless threshold.

Authors:  Kyoung Ho Lee; Young Hoon Kim; Bo Hyoung Kim; Kil Joong Kim; Tae Jung Kim; Hyuk Jung Kim; Seokyung Hahn
Journal:  Eur Radiol       Date:  2006-11-22       Impact factor: 5.315

Review 8.  Noncalcified lung nodules: volumetric assessment with thoracic CT.

Authors:  Marios A Gavrielides; Lisa M Kinnard; Kyle J Myers; Nicholas Petrick
Journal:  Radiology       Date:  2009-04       Impact factor: 11.105

Review 9.  [Low dose multislice CT in the pediatric patient].

Authors:  A Hojreh; F Kainberger; S Puig
Journal:  Radiologe       Date:  2003-12       Impact factor: 0.635

10.  Cardiac multidetector computed tomography: basic physics of image acquisition and clinical applications.

Authors:  Dianna M E Bardo; Paul Brown
Journal:  Curr Cardiol Rev       Date:  2008-08
View more